what is float switch?
float switch is a type of level sensor a device used to detect the
level of liquid within a tank. The switch may be used to control a pump
as an indicator an alarm or to control other devices. One type of float
switch uses a mercury switch inside a hinged float.
how does a float switch works?
float switch is a type of level sensor a device used to detect the level
liquid within a tank. one pattern uses a reed switch mounted in a tube
a float containing a magnet surrounds the tube and is guided by it.
when the float raises the magnet to the reed switch it closes.
(MCB) Miniature Circuit Breaker
Miniature Circuit Breaker MCB automatically switches off electrical
circuit during an abnormal condition of the network means in overload
condition as well as faulty condition.Now days we use an MCB in low
voltage electrical network instead of a fuse.
Magnetic Conductor
Magnetic Conductor is a part or a kit of parts intended for a lossy magnetic
flow generated with current in windings of such devices as transformers
throttles magnetic cartridges filters and circuits.
Single Phase
single phase power is commonly found in residences and commercial
buildings and is primarily used for powering small appliances.
This configuration may either be a simple 120V or a split phase
configuration with 120/240V. Single phase is either a two or three
wire ac circuit.
THANK YOU VERY MUCH WATCHING THIS VIDEO
if you have any questions please comment on
video and subscribe this channel
/ @jrelectricschool
float switch wiring diagram for water pump
• float switch wiring di...
complete electrical house wiring diagram
• complete electrical ho...
split ac wiring diagram indoor outdoor single phase
• split ac wiring diagra...
reverse forward dol starter power wiring
• reverse forward dol st...
electrical house wiring full video
• electrical house wirin...
Two Way switch Connection with light electric animation video
• Two Way switch Connect...
two way switch fan regulator connection diagram
• two way switch fan reg...
house wiring single phase energy meter with light fan connection
• house wiring single ph...
star delta connection 3 phase motor diagram
• star delta power wirin...
3 phase motor dol connection
• 3 phase motor dol conn...
window ac wiring diagram video
• window ac wiring diagr...
Musci by- Ikson: / ikson
keyword:
float switch connection
float switch connection bangla
float switch connection hindi
float switch connection without contactor
float switch connection with motor
float switch connection with dol starter
float switch connection malayalam
float switch connection for water tank
single phase motor
single phase water pump
float switch diagram
float switches for water tanks
float switch installation
float switch for water tank
best float switch for water tank
float switch connection with starter
septic tank float switch installation
float switches for water tanks
water pump control panel wiring diagram
how to connect float switch to 3 phase pump
best float switch for water tank
float switch wire
float switch wiring diagram
float switch stainless
float switch
float switch setup
float switch assembly
float switch schematic
connection of float switch
2 float switch wiring diagram
2 float switch
float switch stainless

Пікірлер: 130

  • @barkatshaikh3736
    @barkatshaikh37363 жыл бұрын

    Very nice Video Very Good Information Sir .❤

  • @JrElectricSchool

    @JrElectricSchool

    3 жыл бұрын

    Thank you very much!

  • @natividadvaldezcueva2618
    @natividadvaldezcueva2618 Жыл бұрын

    Muy agradecido amigo que Dios te bendiga

  • @sarvajeetyadav9460
    @sarvajeetyadav94603 жыл бұрын

    Bhut hi achha hai video sir..but sir ek request hai wiring diagram k sath batayenge humlogo k bhut hi achha rahega

  • @JrElectricSchool

    @JrElectricSchool

    3 жыл бұрын

    i will try Thank you

  • @khaleddara5289
    @khaleddara52893 жыл бұрын

    مشكورين على المعلومات الى الامام انشالله

  • @JrElectricSchool

    @JrElectricSchool

    3 жыл бұрын

    sorry i am not understand your language please tell Bangla Hindi English. Thank you

  • @dhanushkasuraweera6932
    @dhanushkasuraweera69322 жыл бұрын

    If standard numbers are used for the terminals to be connected, it can be clearly learned ... just like the contactor ...

  • @JrElectricSchool

    @JrElectricSchool

    2 жыл бұрын

    Thank you very much for share your opinion!

  • @electricalmaintenanceteam7702
    @electricalmaintenanceteam77022 жыл бұрын

    Nice video vai.

  • @JrElectricSchool

    @JrElectricSchool

    2 жыл бұрын

    Thank you very much

  • @melchoraquino351
    @melchoraquino3512 жыл бұрын

    You don’t need the start, stop push button switch. The HOA switch will do the job starting and stopping the motor. A good circuit design is one that will do the job safely with less parts.

  • @mosesdickson1226
    @mosesdickson12263 жыл бұрын

    If the main power supply is on and if the gen set transfer the load back to the main supply and if the gen set dosent shut down, where can we troubleshoot and identify the fault?

  • @atikruh
    @atikruh3 жыл бұрын

    Thank you👍🙂 my water pump is 0.7kW. Which choise contactor?

  • @hamedmohammadi868
    @hamedmohammadi8682 жыл бұрын

    Hi What program did you use to build this? I need it for my dissertation. Thanks for the reply

  • @dickengun4099
    @dickengun40993 жыл бұрын

    Not a suitable example to demonstrate automatic or manual mode using this scenario. If you turn the selector switch to manual M, you are going to bypass the float switch, that’s fine. You have wired the pump direct with live and neutral. You should use a pressure sensor first then connect with its switch live to the pump. If you bypass the float switch the pump will be on all the time filling up the tank thereby overflowing it.

  • @anthonyfrancis6743

    @anthonyfrancis6743

    Жыл бұрын

    I agree with you Dicken Gun. From my circuit analysis I see that the float switch has been bypassed in the automatic mode. This will cause the pump to run constantly. Therefore the pump will either overfill or run when the tank is empty. These conditions are are not desirable. This is a poor design

  • @kernjohnson2099
    @kernjohnson20992 жыл бұрын

    If I'm using a pilot light toggle switch for manual, instead of the stop/ start buttons, how do I wire it?

  • @GardaCome
    @GardaCome4 жыл бұрын

    Very nice video

  • @JrElectricSchool

    @JrElectricSchool

    4 жыл бұрын

    Thanks for watching

  • @electronicskhan918

    @electronicskhan918

    4 жыл бұрын

    kzread.info/dash/bejne/anaNqdZwfsTOYcY.html👈

  • @Anknow188
    @Anknow1883 жыл бұрын

    Better to place some delay timer because floatswicth are not steady with the flowing of water inside the tank and may casuse yong contactor ang motor damages and i experience it...

  • @abdulrahman-hz1zg
    @abdulrahman-hz1zg3 жыл бұрын

    Super brother What are reason we are using red and green button pls explain and y didn't give netural for green and red button

  • @Odinevsky
    @Odinevsky2 жыл бұрын

    Sir, can you please share the specs of the control devices? thanks

  • @user-cz6ll4ow8r
    @user-cz6ll4ow8r3 жыл бұрын

    Thanks

  • @JrElectricSchool

    @JrElectricSchool

    3 жыл бұрын

    Welcome

  • @beanrobot

    @beanrobot

    Жыл бұрын

    Hey Soozler! I had this same issue. I'm guessing his coil is 220V. You only want 120 V going through the coil. The basic idea is that you only want one side of the coil getting power (left side in this case, via the jumper) and your black float switch wire should be connected to your neutral wire, and the other wire from the switch connected to the right side of the coil. I can send you a diagram if you want.

  • @dhanushkasuraweera6932
    @dhanushkasuraweera69322 жыл бұрын

    Can you tell me the type of contactor you want to buy ...? Please ... Thank you ...

  • @user-ql2bh7wu7x
    @user-ql2bh7wu7x Жыл бұрын

    nice video

  • @JrElectricSchool

    @JrElectricSchool

    Жыл бұрын

    Thanks

  • @risk8272
    @risk82723 жыл бұрын

    deberian poner la numeracion del contactor asi como su bobina

  • @zawmyohtike7554
    @zawmyohtike75543 жыл бұрын

    Sir do you have any video using two float swit for water pump

  • @JrElectricSchool

    @JrElectricSchool

    3 жыл бұрын

    no but i will try to make video on your topic. Thank you.

  • @premmurarisharma425
    @premmurarisharma4253 жыл бұрын

    NICE

  • @JrElectricSchool

    @JrElectricSchool

    3 жыл бұрын

    Thanks

  • @sivanaidu7376
    @sivanaidu73763 жыл бұрын

    Super bro

  • @JrElectricSchool

    @JrElectricSchool

    3 жыл бұрын

    Thanks

  • @mosesdickson1226
    @mosesdickson12263 жыл бұрын

    If power supply is off, and if the gen set is on and transfer the load and then the main power supply comes back on and the gen set continue to run with out transfer load. What is the fault and where can l troubleshoot?

  • @salkhumurmu714
    @salkhumurmu7143 жыл бұрын

    Nice

  • @JrElectricSchool

    @JrElectricSchool

    3 жыл бұрын

    Thanks for watching

  • @GabrielDavid2011
    @GabrielDavid20113 жыл бұрын

    Los cables con tensión entran siempre por arriba. No hay protección en dicho plano que hiciste.. Tenes que saber que los comando se maniobran con 24v/a en tanque. Circuito de fuerza motriz y circuito de comando. La conexión esta mal

  • @lebrunlukombo241
    @lebrunlukombo2413 жыл бұрын

    What is the use of this single wire float in the tank. Je ne comprends pas le rôle de ce flotteur à un fil. C'est joli mais flou. Les boutons rouge NC ou vert NO sont des poussoirs, alors I have not understood.

  • @azizulhaque5040
    @azizulhaque50404 жыл бұрын

    My friend please try to make video without music 😭 Thanks.

  • @JrElectricSchool

    @JrElectricSchool

    4 жыл бұрын

    Thank you so much share your opinion i will try

  • @azizulhaque5040

    @azizulhaque5040

    4 жыл бұрын

    @@JrElectricSchool "You are Most welcome My Dears 🌷

  • @JrElectricSchool

    @JrElectricSchool

    4 жыл бұрын

    @@azizulhaque5040 my pleasure

  • @noelcapacio9804
    @noelcapacio98043 жыл бұрын

    nice

  • @JrElectricSchool

    @JrElectricSchool

    3 жыл бұрын

    Thanks

  • @mbalajiganesan
    @mbalajiganesan3 жыл бұрын

    This circuit not recommended for safety reason, The control supply must be 12v or 24v only recommended. Safety is first , nothing is more important than the safety .

  • @JrElectricSchool

    @JrElectricSchool

    3 жыл бұрын

    Thank you so much for share your opinion

  • @souravankur6559
    @souravankur65593 жыл бұрын

    I want the picture of single pole mcb and with out indicator

  • @FAzhar-hr9xg
    @FAzhar-hr9xg Жыл бұрын

    what is your constraints on this project?

  • @andreeaviciriuc5267
    @andreeaviciriuc52672 жыл бұрын

    Ok felicitări

  • @gadherrahul7458
    @gadherrahul74584 жыл бұрын

    Solar system to bettry charge diagram drowning and use bettry home components

  • @JrElectricSchool

    @JrElectricSchool

    4 жыл бұрын

    i will try to make video on your topic Thank you

  • @electronicskhan918

    @electronicskhan918

    4 жыл бұрын

    kzread.info/dash/bejne/anaNqdZwfsTOYcY.html👈

  • @jobortyadao
    @jobortyadao4 жыл бұрын

    Questions? PO what is the use of E? Nd? PO naka connect? Pasenxia na po sa tanong!!✌️✌️✌️

  • @cristiandestefano8512
    @cristiandestefano85124 жыл бұрын

    In my opinion, if I use the m version, the scheme does not work because in the absence of water you will burn the motor also because you do not even have an electric absorption control

  • @cristiandestefano8512

    @cristiandestefano8512

    4 жыл бұрын

    If I was wrong please tell me why

  • @JrElectricSchool

    @JrElectricSchool

    4 жыл бұрын

    your feedback is very important for me Thank you so much for share your opinion

  • @mohammedm.chiwartabji167

    @mohammedm.chiwartabji167

    3 жыл бұрын

    That means the MCB there is useless if the motor could beburnt

  • @dantudorachi827
    @dantudorachi8273 жыл бұрын

    Interesant Întotdeauna avem de învățat

  • @akhilraj4333
    @akhilraj43333 жыл бұрын

    Sir. how to give indication light in this diagram.... please explain...

  • @JrElectricSchool

    @JrElectricSchool

    3 жыл бұрын

    i will try to make video on your topic. Thank you

  • @akhilraj4333

    @akhilraj4333

    3 жыл бұрын

    Phase passing into water float its very dangerous to human... voltage variation affected to damage float for long life.....

  • @zoheerharrbbi5226
    @zoheerharrbbi52263 жыл бұрын

    tres bien

  • @zoheerharrbbi5226

    @zoheerharrbbi5226

    2 жыл бұрын

    Très bien

  • @rin3326
    @rin33264 жыл бұрын

    Why no use overload contactor no protection motor..

  • @JrElectricSchool

    @JrElectricSchool

    4 жыл бұрын

    it is single phase motor no need overload but you can use for your protection no problem. Thank you

  • @ravicharynagaram1567
    @ravicharynagaram15672 жыл бұрын

    Can you do wiring in manually

  • @JrElectricSchool

    @JrElectricSchool

    2 жыл бұрын

    i will try to make video on your topic. Thank you.

  • @gustavoignaciolopezmillan2196
    @gustavoignaciolopezmillan21962 жыл бұрын

    Chévere

  • @wajidshaikh8941
    @wajidshaikh89413 жыл бұрын

    Konsa part kya work karta hai, uska kya effect hota hai,,,,,ye kon batayega

  • @JrElectricSchool

    @JrElectricSchool

    3 жыл бұрын

    ape internet me search ke jeya ape ko pata chalgaye ge

  • @hiranhandapangoda8451
    @hiranhandapangoda84513 жыл бұрын

    Send me a photo wiring for inveter

  • @JrElectricSchool

    @JrElectricSchool

    3 жыл бұрын

    i will try

  • @robertosantiago5330
    @robertosantiago53303 жыл бұрын

    Tengo una bomba sumergible y tengo que controlar dos o más cisternas con eletronives

  • @JrElectricSchool

    @JrElectricSchool

    3 жыл бұрын

    sorry i am not understand your language please tell Bangla Hindi English. Thank you

  • @aungmyohtet9469
    @aungmyohtet94692 жыл бұрын

    when auto system is running, line signal is reverse to Manual point

  • @lorpeanuran8567
    @lorpeanuran85673 жыл бұрын

    What model magnetic contactor thanks.

  • @JrElectricSchool

    @JrElectricSchool

    3 жыл бұрын

    schneider magnetic contactor

  • @rafshankhanrafshan96
    @rafshankhanrafshan962 жыл бұрын

    Submersible ka canection kar na hoga to kiya kar na hoga 1 phase canection Submersible

  • @mohamadmsheik2296
    @mohamadmsheik22963 жыл бұрын

    Please name the circuit diagram program

  • @JrElectricSchool

    @JrElectricSchool

    3 жыл бұрын

    animation

  • @twincaturinspirants4135
    @twincaturinspirants41353 жыл бұрын

    I used PowerPoint 2019 animation

  • @JrElectricSchool

    @JrElectricSchool

    3 жыл бұрын

    best of luck

  • @kingapitedit3903
    @kingapitedit39033 жыл бұрын

    Lain kali di buat kode NC & NO nya

  • @sriganesanvinayagar7555
    @sriganesanvinayagar75553 жыл бұрын

    No back round music pl sir

  • @JrElectricSchool

    @JrElectricSchool

    3 жыл бұрын

    Thank you so much for share your opinion i will try

  • @abduljabbar_pbd
    @abduljabbar_pbd3 жыл бұрын

    Motor Panel ryb kya conction

  • @JrElectricSchool

    @JrElectricSchool

    3 жыл бұрын

    RYB is 3 phase line

  • @cyrilnouague1520
    @cyrilnouague15203 жыл бұрын

    Svp quel est le nom du logiciel que vous utiliser pour faire votre dessin ?

  • @JrElectricSchool

    @JrElectricSchool

    3 жыл бұрын

    sorry i am not understand your language please tell me Bangla,Hindi,English. Thank you.

  • @sakthivelp1214
    @sakthivelp12143 жыл бұрын

    Still i can't able to understand Auto and manual concept....Pls explain anyone

  • @JrElectricSchool

    @JrElectricSchool

    3 жыл бұрын

    your water pump run automatic

  • @sakthivelp1214

    @sakthivelp1214

    3 жыл бұрын

    @@JrElectricSchool ok..But the wiring concept is not understand...Explain it

  • @NandanKumar-je8vs
    @NandanKumar-je8vs4 жыл бұрын

    5 मंजिल से मोटर चलना चाहिए

  • @electronicskhan918

    @electronicskhan918

    4 жыл бұрын

    kzread.info/dash/bejne/anaNqdZwfsTOYcY.html👈

  • @vikashnirmalofficial8206
    @vikashnirmalofficial82064 жыл бұрын

    Sir kama shikhana ha Bhai

  • @JrElectricSchool

    @JrElectricSchool

    4 жыл бұрын

    ko e problem ne he ape youtube se seksakte he free

  • @vikashnirmalofficial8206

    @vikashnirmalofficial8206

    4 жыл бұрын

    @@JrElectricSchool Kon school ke sir electric he

  • @vikashnirmalofficial8206

    @vikashnirmalofficial8206

    4 жыл бұрын

    Admission sir karana ha

  • @JrElectricSchool

    @JrElectricSchool

    4 жыл бұрын

    @@vikashnirmalofficial8206 ape internet me search ke jeya

  • @electronicskhan918

    @electronicskhan918

    4 жыл бұрын

    kzread.info/dash/bejne/anaNqdZwfsTOYcY.html👈

  • @Amjad.hossan
    @Amjad.hossan4 жыл бұрын

    Stop bottom to contactor no why need connection

  • @JrElectricSchool

    @JrElectricSchool

    4 жыл бұрын

    holding connection

  • @electronicskhan918

    @electronicskhan918

    4 жыл бұрын

    kzread.info/dash/bejne/anaNqdZwfsTOYcY.html👈

  • @rahadmahamudalim3650
    @rahadmahamudalim36504 жыл бұрын

    ভাইয়া আপনি কি সফটওয়্যার ব্যবহার করেন দয়া করে একটু লিংকটা দিবেন আমাকে।

  • @JrElectricSchool

    @JrElectricSchool

    4 жыл бұрын

    i am so sorry for youtube community guidelines

  • @elenaivanova452
    @elenaivanova4523 жыл бұрын

    [power electric motor]]

  • @JrElectricSchool

    @JrElectricSchool

    3 жыл бұрын

    yes! Thanks for watching

  • @amullabarman8024
    @amullabarman80242 жыл бұрын

    প্রতিটি পয়েন্ট এর নাম উল্লেখ্য করে দিলে যারা জানেনা তারা শিখতে পারত। আপনার উদ্দেশ‍্য তো শিখানো তাইনা?

  • @ahmedelbaana9653
    @ahmedelbaana96533 жыл бұрын

    Weher the over load.

  • @JrElectricSchool

    @JrElectricSchool

    3 жыл бұрын

    it is single phase motor no need overload but you can use no problem

  • @C0STPU55
    @C0STPU553 жыл бұрын

    e' incompressibile,,,,,si deve prima fare lo schema elettico, manca lo stoz degli ausiliari.....

  • @anthonyfrancis6743
    @anthonyfrancis6743 Жыл бұрын

    This is a poor design, the float switch is not in the circuit in the automatic mode, this could be catastrophic depending on the process it is used for

  • @jaswant9228
    @jaswant92283 жыл бұрын

    Waring rong

  • @jaswant9228

    @jaswant9228

    3 жыл бұрын

    L rong hai

  • @JrElectricSchool

    @JrElectricSchool

    3 жыл бұрын

    why?

  • @ahjed7397

    @ahjed7397

    3 жыл бұрын

    @@JrElectricSchool manual to 14? which will trigger the coil a1 and a2 in manual?

  • @ramyavijay1596
    @ramyavijay15962 жыл бұрын

    Ra mya

  • @elidrisidris8395
    @elidrisidris83952 жыл бұрын

    Complicated

  • @jorgeramos2327
    @jorgeramos23273 жыл бұрын

    Nice

  • @JrElectricSchool

    @JrElectricSchool

    3 жыл бұрын

    Thank you so much

  • @mosesdickson1226
    @mosesdickson12263 жыл бұрын

    If power supply is off, and if the gen set is on and transfer the load and then the main power supply comes back on and the gen set continue to run with out transfer load. What is the fault and where can l troubleshoot?

Келесі