Fixing My Baseboard Heater Zone Valve

Тәжірибелік нұсқаулар және стиль

Troubleshooting and fixing my Honeywell Zone Valve. When zone valves fail they can leave you without heat, usually at the worst time. Take the time and learn how to do this simple job.

Пікірлер: 38

  • @cannon440
    @cannon4402 жыл бұрын

    Thank you very much. I saved over $1000 replacing 3 zone valves myself. I bought 3 Honeywell V8043E1012 $210 with tax & free shipping. I left the old housing in place & replaced all the moving parts. It was easy & now should work for many years.

  • @AlaskaWorkshop

    @AlaskaWorkshop

    2 жыл бұрын

    Fantastic, glad it helped you out!

  • @williamgarey8114
    @williamgarey811410 ай бұрын

    Very good information I was getting ready to sweat the whole valve out. Changing the ball is easier.

  • @AlaskaWorkshop

    @AlaskaWorkshop

    10 ай бұрын

    Glad it helped. I just did a second one last week. They have lasted 30 years. One more zone to go, I have the part on the shelf!

  • @paulness8352
    @paulness83522 жыл бұрын

    If theres anything that living in Alaska has taught me, its how to be a better DIYer. Because most services charge an outrageous price, and a great deal dont do quality work. At least when you DIY, you have a vested interest in making sure its done correctly. Thanks for the vid.

  • @AlaskaWorkshop

    @AlaskaWorkshop

    2 жыл бұрын

    Very true, hard to find a contractor……especially when it is 20 below!

  • @buildingnfixing7348
    @buildingnfixing7348 Жыл бұрын

    thank you for sharing. its ironic that the board game: The Game Of Life is in the background. Excellent video. its nice to see someone working on an actual boiler.

  • @AlaskaWorkshop

    @AlaskaWorkshop

    Жыл бұрын

    Haha, thanks for taking time for a comment.

  • @Ratlins9
    @Ratlins92 жыл бұрын

    Excellent video, great camera work as well as your explanation of the valves, motor and wires. I have a much better understanding of this system because of this video.

  • @AlaskaWorkshop

    @AlaskaWorkshop

    2 жыл бұрын

    Thanks Ken

  • @user-mk7pf6to5x
    @user-mk7pf6to5x Жыл бұрын

    Thanks for the simple explanation of what your doing.

  • @AlaskaWorkshop

    @AlaskaWorkshop

    Жыл бұрын

    You are welcome. Thank you for commenting!

  • @akusantafe
    @akusantafe Жыл бұрын

    Outstandingly clear explanation of the process.

  • @AlaskaWorkshop

    @AlaskaWorkshop

    Жыл бұрын

    Thank you and thanks for leaving a comment to say so!!

  • @akusantafe

    @akusantafe

    11 ай бұрын

    @@AlaskaWorkshop I should add that this video did guide me through the process successfully. There are MANY useful tips in this video.

  • @k2silence
    @k2silence2 жыл бұрын

    Good work, as an hvac tech who works with a lot of hydronic heating systems I’ve ran into the same problem too. Newer style zone valves a lot are better they don’t have that issueb

  • @AlaskaWorkshop

    @AlaskaWorkshop

    2 жыл бұрын

    Thanks, seems like I get failures only during our -20F cold snaps!

  • @tacrewgirl
    @tacrewgirl2 жыл бұрын

    As a fellow Alaskan, I think this is my baseboard issue too. Thanks for the video.

  • @AlaskaWorkshop

    @AlaskaWorkshop

    2 жыл бұрын

    Hopefully pointed you in the right direction before winter sets in.....wait it is already winter here in Southcentral. lol

  • @katnisseverdeeniwontbesile337
    @katnisseverdeeniwontbesile337 Жыл бұрын

    Ur boiler is just like my mom's! U helped a great deal thank u so much for sharing!

  • @AlaskaWorkshop

    @AlaskaWorkshop

    Жыл бұрын

    You are so welcome! Love the name.

  • @michellewilliams4land535
    @michellewilliams4land5352 жыл бұрын

    Great explainer, Thank you from Soldotna!!

  • @AlaskaWorkshop

    @AlaskaWorkshop

    2 жыл бұрын

    Thanks for the kind comment. Love the Kenai Peninsula.

  • @roberttombs3108
    @roberttombs3108 Жыл бұрын

    Nice system

  • @mohawkmike142
    @mohawkmike1429 ай бұрын

    Nice job for a non pro. Nice neat workmanship there. Want to ad though. Open that ball valve on the capped off branch. The ball face on ball valves will corrode if touching the water long term. Ball vales like to be open and only closed in the short term.

  • @AlaskaWorkshop

    @AlaskaWorkshop

    9 ай бұрын

    Thank you, makes sense!

  • @beavence
    @beavence7 ай бұрын

    Great video thanks. One doubt since my system is a bit different, do you have to drain a lot of water before opening the valve? Or as long as u close the incoming cold water and return plus the hot water and return, will it be ok to drain just few liters?

  • @AlaskaWorkshop

    @AlaskaWorkshop

    7 ай бұрын

    That's what I did. You may want to consider flushing the entire system if it has not been done in a while. I did mine not long ago.

  • @misssarahruth
    @misssarahruth Жыл бұрын

    Thanks for this video! I hope this is my issue and not something worse 😂

  • @AlaskaWorkshop

    @AlaskaWorkshop

    Жыл бұрын

    It may not even be as bad. If you are not getting heat to one zone, try replacing just the valve replacement head and not the entire valve. Good luck.

  • @alainmoise6188
    @alainmoise61887 ай бұрын

    good morning if the zone valve make noise how to do ?

  • @vgvwbug105
    @vgvwbug1058 ай бұрын

    We have an issue that the thermostat says 73 but the house is cold. So the baseboards won’t turn on unless we put the temp up. Do you have any tips or advice as to what the issue could be

  • @AlaskaWorkshop

    @AlaskaWorkshop

    8 ай бұрын

    Sounds like a thermostat problem. I had one in my garage that I had to set to 90 just to keep it at 70. Test the real temp with a separate thermometer.

  • @Illmatic1989
    @Illmatic19896 ай бұрын

    I need help. My 1st floor doesnt heat when thermo set to 75 for example. When I turn on the heat in the basement, than the 1st floor starts getting heat. Im confused why that is? Only basement thermostat will turn the heat on. Right now somehow the 1st floor is on, but some nights at 15 degree weather it doesnt heat with thermostat already set. I than go to the basement and turn on the basement heat to get 1st flr heat. Help please. I need to know if this valve may be my issue instead of the thermostat.

  • @AlaskaWorkshop

    @AlaskaWorkshop

    6 ай бұрын

    Do you have 2 zones? You can test whether the zone works by having someone turn up the thermostat and watch the valve open. You can also feel the zone pipes, if the valve is open it should be hot. My system only has 2 wires (heat only). I can check the thermostat by connecting the 2 wires together. If the thermostat is calling for heat and not coming on and the 2-wire trick works, it is the thermostat.

  • @Illmatic1989

    @Illmatic1989

    6 ай бұрын

    Both are hot and heat is set to 72ish on the first floor. 70 in the basement. Im not sure if theres 2 wires. I know it’s 2 separate valves labeled basement and 1st floor. My neighbors is on the other side of the wall. But on my side its 2 seperate honeywell valves in 2 seperate boxes identical to your setup. Its a gas weil mclain furnace. Heat is currently on and the switch on top is all the way to the right set to open. Just dont understand why I would turn on the basement to get heat on 1st floor.

  • @AlaskaWorkshop

    @AlaskaWorkshop

    6 ай бұрын

    @@Illmatic1989 Really odd. My advice is to call a repair guy and watch what he does to troubleshoot. Ask lots of questions about your setup and get your money's worth. Good luck, stay warm.

  • @Moymoy-25
    @Moymoy-252 ай бұрын

    3 zone valves with 1 24v transformer. My coworkers making me look like dumb at work. The way they engineered hydronic systems was a crap at work. Hotel😂😂😂😂. A few believes. The engineers are rusty 😂😂😂😂. They don’t know basic electric currents and wattages😂😂😂