No video

Error code 7 - Hyster J2.50XM forklift

This forklift shows error 7 Call Service Technician.
It means that the accelerator sensor voltage has exceed 11Volt at startup.
This input voltage can be found in the display.
And the sensor has to be mechanically adjusted.
For more forklift video`s see my playlist:
• All Material Handling ...
Feel free to watch, add a comment, like and subscribe for more!
Thank u for watching!

Пікірлер: 13

  • @ezequiellauria8330
    @ezequiellauria8330 Жыл бұрын

    Hi, im argentinaen, im not speak English.i have a problem but Hyster J2.50EX, the display say error 184. No move lift,and no move traction.what is this solution.

  • @1600GSI

    @1600GSI

    Жыл бұрын

    Hi there, I don't have a manual or error description for this model. You have to call a Hyster technician or representative. Regards

  • @1600GSI

    @1600GSI

    11 ай бұрын

    And did you find out the error 184 on youre Hyster allready??

  • @ezequiellauria8330

    @ezequiellauria8330

    11 ай бұрын

    @@1600GSI sulfated rear display

  • @abedm3393
    @abedm33932 жыл бұрын

    Hello , we have hyster j2.50xm when trying to go forward or backword it moves slightly and stops , and that movment is only happening when the pedal is at certain position , what do you think the problem is ( the screen isnt working to show error codes ) .

  • @1600GSI

    @1600GSI

    2 жыл бұрын

    Hard to say if the display isn't working already. You will have to replace the display or read out the truck with diagnostic software. Otherwise you would have to measure everything like battery voltage, accelerator switch and sensor etc etc

  • @abedm3393

    @abedm3393

    2 жыл бұрын

    @@1600GSI we did fix the original display , it shows error 90 , AC traction motor high temperature . I bypassed the temperature sensor and the 3 phase cables were heating up , so now we are disassembling the front side to take out the motor for inspection .

  • @veryfanny4004
    @veryfanny400419 күн бұрын

    Hi i have erreur code 52 Friend sollicitons plys

  • @alisgonzalez745
    @alisgonzalez745 Жыл бұрын

    I am working on an electric hyster E100ZS the equipment turns on everything well but at the time of driving it is difficult for it to come out as if it were braking and then it rolls well when I brake the same procedure it is difficult for it to go what opinion would you give me in that case

  • @1600GSI

    @1600GSI

    Жыл бұрын

    Check the battery voltage under load. That the voltage isn't dropping to much when accelerating or lifting. Als check the electro motors like jammed or worn-out brushes. And als that the brake and handbrake is releasing properly.

  • @44cheato
    @44cheato3 жыл бұрын

    Any video for Hyster N40ZR?

  • @1600GSI

    @1600GSI

    3 жыл бұрын

    I hardly have a Hyster N40ZR here yet, but keep an eye on it.

  • @lormoon

    @lormoon

    2 жыл бұрын

    Hello! My forklift display does not turn on... Any advice on that matter?