Electric Fire Pump Performance Test

Fire pump testing.
Fire pump performance test.

Пікірлер: 43

  • @rellylimpiada1531
    @rellylimpiada15312 жыл бұрын

    Nice and informative video. Only missing in the review of results is the speed correction of discharge pressures. Hope this helps.

  • @shamsheralam8862
    @shamsheralam88622 жыл бұрын

    EXCEPTIONAL, VERY CLEAR INFORMATION THANKS A LOT ..PLZ MAKE MORE SUCH VEDIOES

  • @GracejunOfficial
    @GracejunOfficial3 жыл бұрын

    Nice intro dagdagka alaman kapatid thanks for sharing keep safe injoy vloging kapatid tusuk na

  • @mohieldeen9140
    @mohieldeen91402 жыл бұрын

    Thank you very much sir, this video help me alot 🙏

  • @priyamunna7435
    @priyamunna74353 жыл бұрын

    Nice video 🤗🤗

  • @arun4846
    @arun4846 Жыл бұрын

    Thanks ❤️👍🎉

  • @junaidhaneefiuliyathadukka8839
    @junaidhaneefiuliyathadukka88392 жыл бұрын

    thanks a lot ....

  • @abderraoufbenchamakh3435
    @abderraoufbenchamakh34352 жыл бұрын

    nice video

  • @ladyjay3551
    @ladyjay35513 жыл бұрын

    Nice kuya

  • @junaidhaneefiuliyathadukka8839
    @junaidhaneefiuliyathadukka88392 жыл бұрын

    need your more videos about other fire protection system as this video did..

  • @adlearningofficialchannel6683

    @adlearningofficialchannel6683

    2 жыл бұрын

    Thank sir new videos coming soon…

  • @sanosagara4507

    @sanosagara4507

    Жыл бұрын

    @@adlearningofficialchannel6683 thank you for making clear video regarding performance test, however, how can you run a fire pump while your inlet and outlet valvles are totally closed? Is your pump will gonna explode?

  • @adlearningofficialchannel6683

    @adlearningofficialchannel6683

    Жыл бұрын

    @@sanosagara4507 thank you for appreciating my efforts Sir. inlet valves are in open condition and test line valves are opened in accordance with the flow requirement. Only the system valve is closed to isolate the system in the building.

  • @mohamedalthafhussain9632
    @mohamedalthafhussain9632 Жыл бұрын

    Thanks for your videos and appreciate your efforts .. General question how long we have to run for each condition and when we have to take reading while holding time if 0% at flow . & For 100 &150% flow if 10 minutes is a holding time

  • @adlearningofficialchannel6683

    @adlearningofficialchannel6683

    Жыл бұрын

    for Electric pumps at no flow (churn), you may run the pump 10mins. Please don't forget to no monitor the condition of pump e.g. temperature, weird noise, smoke from gland,.

  • @mohamedalthafhussain9632

    @mohamedalthafhussain9632

    Жыл бұрын

    @@adlearningofficialchannel6683 Thanks for response 👍.. keep posting to learning skills.. Thx😊

  • @Crazypants415
    @Crazypants415 Жыл бұрын

    Where is the audio? Please help I need this for a homework assignment

  • @adlearningofficialchannel6683

    @adlearningofficialchannel6683

    2 ай бұрын

    No audio sir just watch the video

  • @user-op4vo9cm6b
    @user-op4vo9cm6b Жыл бұрын

    I have a question: where can I find the code that shows "at 0% the pressure should not exceed 140% of the design pressure"? Is it NFPA 25? If it is, which chapter & section shows this regulation? Thanks

  • @adlearningofficialchannel6683

    @adlearningofficialchannel6683

    Жыл бұрын

    You may refer to NFPA 20 and look for Factory and Field Performance.

  • @ozur6e53yd
    @ozur6e53yd3 жыл бұрын

    Its me su rafi nice vid

  • @adlearningofficialchannel6683

    @adlearningofficialchannel6683

    3 жыл бұрын

    Thanks a lot. Preparing more videos.

  • @siegfredvisitacion736
    @siegfredvisitacion7362 жыл бұрын

    I have a question 1. Is it ok to put emergency generator for the electric fire pump in place of a diesel driven pump? 2. Example scenario "I will install Diesel Driven Fire Pump for the building. Is there any rule in NFPA or other standards that requires another installation of electric driven pump? Answers showing NFPA or other STANDARD provision is much appreciated... Thanks

  • @adlearningofficialchannel6683

    @adlearningofficialchannel6683

    Жыл бұрын

    That will depend on your local AHJ sir. You have to request clarification from them. In some countries it is required to have standby and duty. Standby shall be diesel pump otherwise provided with secondary power supply if electric driven.

  • @meljohniyoy1987
    @meljohniyoy19876 ай бұрын

    Question sir, if we closed the main isolation valve going to bldg. And also the up & downstream near the flowmeter. There will be a build up of pressure? It is safe? For zero flow

  • @adlearningofficialchannel6683

    @adlearningofficialchannel6683

    5 ай бұрын

    You have to make sure all equipment are rated above the maximum pressure of pump and prior to testing make sure that hydrotest was already conducted to the piping network.

  • @romanroute7289
    @romanroute7289 Жыл бұрын

    Hi. This is a very strange test. Why is your suction pressure always 0 PSI? Do you have an underground tank and no low zone pump ? Normally, at 150% flow, for split case pumps D 400 mm NPSHR should be about 5 psi, to avoid cavitation. That being said, the suction pressure gauge reads about 4-5 psi. Without flow, the suction pressure should be equal to the liquid column pressure in the tank or the low zone pump pressure. How did you test the pump with no suction head?

  • @adlearningofficialchannel6683

    @adlearningofficialchannel6683

    Жыл бұрын

    This was just made to guide others how to conduct the testing. In actual situation, the suction line pressure will differ depending on the elevation of the tank or if the supply is coming from another pump.

  • @romanroute7289

    @romanroute7289

    Жыл бұрын

    @@adlearningofficialchannel6683 Yes, but colleagues may think that 0 PSI at suction means that the suction valve is closed. Everyone should be more careful and never close the suction valve

  • @nourel-moubarekel-tayeb8215
    @nourel-moubarekel-tayeb82155 ай бұрын

    I can’t find -3 psi requirement for the suction pressure neither in NFPA 20 nor NFPA 25, what’s your reference please ?

  • @adlearningofficialchannel6683

    @adlearningofficialchannel6683

    2 ай бұрын

    Dear Sir, Please refer to NFPA 20 Chapter 4 suction size

  • @jeneriofernandez682
    @jeneriofernandez682Ай бұрын

    How about the performance test of Diesel engine

  • @adlearningofficialchannel6683

    @adlearningofficialchannel6683

    Ай бұрын

    Similar criteria Sir.

  • @darwinlim4837
    @darwinlim4837 Жыл бұрын

    Sir at zero flow rate if you close the isolation valves at upstream and downstream. Is it safe that pump is running but does not discharge?

  • @adlearningofficialchannel6683

    @adlearningofficialchannel6683

    Жыл бұрын

    Yes sir for 10mins at 0 flow condition for electric fire pumps.

  • @romanroute7289

    @romanroute7289

    Жыл бұрын

    @@adlearningofficialchannel6683 Is this really safe? The electric pump has a cooling water flow valve (this valve opens when the pump is running with no water flow) and prevents the pump from overheating. The water flow through this valve is about 60 l/min. After 10 minutes there will be no water left in the suction pipe or in the pump and the pump will overheat. Why close the suction gate valve? What does it do?

  • @adlearningofficialchannel6683

    @adlearningofficialchannel6683

    Жыл бұрын

    @@romanroute7289 My apology for the confusion. Suction valves will be kept open during the testing. Only the isolation valve for the system will be kept closed and test line valve will be opened according to the flow requirement of the testing e.g. 100% or 150%.

  • @romanroute7289

    @romanroute7289

    Жыл бұрын

    @@adlearningofficialchannel6683 Exactly. The isolating valve and the test line valve can be completely closed for example during weekly tests without water flow for as long as you like, but it is imperative that the minimum water flow valve works correctly and is open when the pump is running and then the pump does not overheat. The suction valve must never be closed when the pump is running.

  • @javierquintero3785
    @javierquintero37852 ай бұрын

    Under what code were the acceptance criteria taken?

  • @adlearningofficialchannel6683

    @adlearningofficialchannel6683

    2 ай бұрын

    Dear Sir, NFPA 25 & 20

  • @javierquintero3785

    @javierquintero3785

    2 ай бұрын

    @@adlearningofficialchannel6683 Thansk

  • @ypss7935
    @ypss79352 жыл бұрын

    Audio..??

  • @adlearningofficialchannel6683

    @adlearningofficialchannel6683

    Жыл бұрын

    Still practicing my editing skills hahaha