EG4 18KPV Upgrade Program Installation Part 2 & Testing

Ғылым және технология

$50 off orders over $500 with code : RODNEYHUNT50
Upgrade Program info HERE! signaturesolar.com/upgrade-pr...
EG4 18KPVHybrid Inverter: signaturesolar.com/eg4-18kpv-...
EG4 Powerpro battery: signaturesolar.com/eg4-powerp...
EG4 Conduit Box: signaturesolar.com/eg4-powerp...
3 inch Core Drill Bit: amzn.to/4bWilaq
100 Amp Disconnect amzn.to/3TJ9H6M
IMO PV Disconnect signaturesolar.com/dc-disconn...
MY CURRENT SYSTEM EQUIPMENT USED:
(3) EG4 6000XP INVERTERS signaturesolar.com/eg4-6000xp...
(17) EG4 Batteries signaturesolar.com/eg4-lifepo...
(12) 305 WATT HYUNDAI SOLAR PANELS signaturesolar.com/hyundai-9-...
(28) SOLARVER 455 WATT PANELS signaturesolar.com/?ref=rodne...
(2) VICTRON LYNX POWER IN BUSBARS amzn.to/48ub3bz
(1) VICTRON LYNC DISTRIBUTOR signaturesolar.com/victron-en...
(2) 4/0 BATTERY RACK CABLE SETS signaturesolar.com/96in-4-0-a...
(8) 2 AWG BATTERY AND INVERTER CABLE SETS signaturesolar.com/72in-2-awg...
(1) 500FT PV WIRE FOR DIY signaturesolar.com/500-ft-12-...
(1) CHARGEVERTER 100 AMP BATTERY CHARGER signaturesolar.com/eg4-charge...
(12) MC4 CONNECTORS signaturesolar.com/staubli-mc...
ALL LINKS ARE AFFILIATES WHICH HELPS THIS CHANNEL WITH A SMALL COMMISION FROM EACH SALE

Пікірлер: 55

  • @jayholmes8893
    @jayholmes88932 ай бұрын

    Hello there Rondey just wanted you to know that you have done a wonderful job on your Install it Looks great and I am Learning from your video keep up the good work.

  • @rodneyhunt

    @rodneyhunt

    2 ай бұрын

    Glad to help! Thanks 👍

  • @Jackflash219
    @Jackflash2192 ай бұрын

    Appears it worked out to be a clean install, out of the weather! Great Job!

  • @rodneyhunt

    @rodneyhunt

    2 ай бұрын

    Yes it was! Thanks

  • @tjmooney4181
    @tjmooney41812 ай бұрын

    Thanks rodney in order to change the time on the app click the little man button top right and set timezone 😉

  • @rodneyhunt

    @rodneyhunt

    2 ай бұрын

    I have several times and then set it. It just won’t take. Time never changes but I will continue to work on it when I have time. Thanks!

  • @jiminsav
    @jiminsav2 ай бұрын

    you Go Rodney. that looks almost professional.

  • @rodneyhunt

    @rodneyhunt

    2 ай бұрын

    Lol. Far from it but I am learning! Thanks

  • @An_Appeal_To_Heaven
    @An_Appeal_To_Heaven2 ай бұрын

    Next week, EP Cube install video.

  • @rodneyhunt

    @rodneyhunt

    2 ай бұрын

    Lol! I can’t finish the projects I have now. But that would be nice to test

  • @afreeland
    @afreelandАй бұрын

    Was curious about the breaker size on the AC disconnect. I can't seem to find the recommended breaker size listed anywhere. The manual did mention the inverter capable of a 50amp backfeed, and lots of references to 200 amp service...just curious on the decision for 100amp AC disconnect. I am closing in on these final stages of wiring so curious to hear. =)

  • @rodneyhunt

    @rodneyhunt

    Ай бұрын

    I used a 100 amp disconnect since the backfeed breaker is 70 amps. So should always be well under the 100 amp disconnect. If you are using the tap on main grid power then you can do 200 amp disconnect but if not then 100 amp is more economical

  • @SteveG_Maine_
    @SteveG_Maine_2 ай бұрын

    You're a good son. Nice setup.

  • @rodneyhunt

    @rodneyhunt

    2 ай бұрын

    I appreciate that. Can’t wait to get all panels installed

  • @bobcole3852
    @bobcole38522 ай бұрын

    Well done!

  • @rodneyhunt

    @rodneyhunt

    2 ай бұрын

    Thank you! Appreciate the support

  • @ikediashitimothyonuorah417
    @ikediashitimothyonuorah417Ай бұрын

    Hello sir, please is it true the EG418Kpv has 3 MPPTs with 600VDC max input on each MPPT? Please i need a clear answer as this is confusing to me. Thanks for your response in advance

  • @rodneyhunt

    @rodneyhunt

    Ай бұрын

    Yes it has 3 MPPT’s with the first having 2 inputs and 1 input for each additional MPPT. 600 volts per MPPT max but working range is 100-500 for MPPT to be active

  • @ikediashitimothyonuorah417

    @ikediashitimothyonuorah417

    Ай бұрын

    @@rodneyhunt Thanks sir 🙏🙏

  • @beeroy26
    @beeroy26Ай бұрын

    Trying to understand how you have it wired up in this video. So if its not currently setup to the subpanel, you have it wired from the grid side of the inverter only and its feeding back through those wires from PV and Battery? Or have the the load side of the inverter circling back around into the main panel?

  • @rodneyhunt

    @rodneyhunt

    Ай бұрын

    Yes its going back through the grid input. It goes to main panel to help run loads and zero out grid input when possible. Then charge battery with excess. I have the CT’s in the main panel for this to work correctly on the main wires l1 l2 from the grid.

  • @beeroy26

    @beeroy26

    Ай бұрын

    @rodneyhunt wow!! If this is to code and/or safe to do without actually sending back to utility, it's a game changer! I'm currently deciding on how I'm going to wire up my 18kpv without sending back to utility (will take a while to jump through all the hoops to get city and utility approval)temporarily and will likely use your method.

  • @chadcarrington1218
    @chadcarrington12182 ай бұрын

    I would like to know more about your solar panel install on the porch. Where did you get the metal? How much? How you attached it? Could you make a video on it? I'm planning to do this on my house.

  • @rodneyhunt

    @rodneyhunt

    2 ай бұрын

    Hey I used unistrut. More info on my tilt array video that should explain everything. Let me know if you need more help after that. 👍

  • @amio_roseto1
    @amio_roseto12 ай бұрын

    good work

  • @rodneyhunt

    @rodneyhunt

    2 ай бұрын

    Thanks! Appreciate that

  • @timlochner9147
    @timlochner91472 ай бұрын

    I was wondering can u use ct clamps on the 6000xp like u have set up on the 18k using like a grid tie inverter?

  • @rodneyhunt

    @rodneyhunt

    2 ай бұрын

    No it is a off grid only inverter. You can pull power from the grid but only power your inverter load side. That is an awesome feature of the 18k

  • @BY-tt3vc
    @BY-tt3vc2 ай бұрын

    I was trying to listen, but might have missed it. Is the panel bus 225 amp rated?

  • @rodneyhunt

    @rodneyhunt

    2 ай бұрын

    Yes. Didn’t talk about that. I recorded tons but decided to cut most out. After installing more panels the load testing will be more fun than the installation.

  • @garybryan33
    @garybryan332 ай бұрын

    As I understand it, even if you have the no-export feature activated, it might at times send out small amounts of power (detectable amounts) to the grid resulting in issues with the power company What has your experience been? I am installing my system and I was leaning toward an off-grid setup with a transfer switch in case I needed grid power.

  • @rodneyhunt

    @rodneyhunt

    2 ай бұрын

    Have not been running long but I have it set to “fast” I think is the setting. So it should in theory keep you from sending back to grid. Have not seen it going back when I have looked. Need to look on app to verify it says zero sent to grid. I am more of a do and ask for forgiveness later type person lol. Will keep you updated

  • @rodneyhunt

    @rodneyhunt

    2 ай бұрын

    Just looked at it says .1kwh sent to grid. Might have been before I had fast setting set. Will add that to future video updates and testing! Thanks

  • @peterd1973
    @peterd19732 ай бұрын

    First! I've been waiting for this video to come out. Thanks 🎉

  • @rodneyhunt

    @rodneyhunt

    2 ай бұрын

    Hope you enjoyed it!

  • @Scat.original
    @Scat.original2 ай бұрын

    Can you provide links for disconnect, Harbor Freight ratchet set, wire way under main panel? Thanks Scat

  • @rodneyhunt

    @rodneyhunt

    2 ай бұрын

    Will try to add it tonight!

  • @jayholmes8893
    @jayholmes88932 ай бұрын

    Hey Rondey could you please tell me what kind of disconnect box that is and what size it is thank you

  • @rodneyhunt

    @rodneyhunt

    2 ай бұрын

    The 100 amp Siemens from home depot.

  • @UnkyjoesPlayhouse
    @UnkyjoesPlayhouse2 ай бұрын

    I recently purchased a 6000XP and while I like the design, build quality, and the cost, there is no way these inverters will last compared to a similar "transformer" based inverter will. My Victron system costs quite a bit more money, but you get what you pay for. This EG4 will be setup to run my Mini Split's (4) of them this summer, we will see how it stands up to the abuse. Thanks for your videos.

  • @rodneyhunt

    @rodneyhunt

    2 ай бұрын

    Thanks. Sounds great!

  • @tb3780

    @tb3780

    2 ай бұрын

    You can replace these every five years and would still come out ahead vs Victron

  • @punksjutgbd

    @punksjutgbd

    2 ай бұрын

    Get a soft starter.

  • @ScottieBMan

    @ScottieBMan

    2 ай бұрын

    Agree, I have been beating my 6000XP with a well pump I believe is 3/4 HP with large inductive load…it trips every once in awhile, then will run for 4 days no issues, perhaps I don’t have enough battery for it (only 2 Eg4 LL right now)

  • @stephanied143
    @stephanied1432 ай бұрын

    Did you use no ox on that aluminum wire

  • @rodneyhunt

    @rodneyhunt

    2 ай бұрын

    Ox?

  • @stephanied143

    @stephanied143

    2 ай бұрын

    @@rodneyhunt it's a coating for aluminum wire its called no-ox

  • @RollinHomies

    @RollinHomies

    2 ай бұрын

    Good eye. Aluminum wire needs to have the gel on the terminals.

  • @rodneyhunt

    @rodneyhunt

    2 ай бұрын

    No but I can add it. Not an electrician and didn’t think about it. Thanks

  • @stephanied143

    @stephanied143

    2 ай бұрын

    @@RollinHomies it's more for the wire to keep from oxidizing brush it into wire real good .