Earth electrode testing the proper way

Ғылым және технология

In this video im back at the new service i recently fitted to conduct some proper earth electrode tests after previously jsut getting a earth fault loop impeadance result.
Earth Electrode testing with Paul Meenan:
• Testing a ConduDisc ea...
If you enjoy electrical content please subscribe to the channel and checkout my links below 👇
M Y W E B S I T E ⚡
residualcurrent.com/
M Y L O A D O U T 🛠️
residualcurrent.com/pages/loa...
B I G B O O T S D I S C O U N T 🥾
bigboots.co.uk/?ref=4s3760y77o - Use code RESIDUAL
U N I L I T E D I S C O U N T 🔦
unilite.co.uk/?ref=RESIDUAL - Use code RESIDUAL
J O I N T H E C H A N N E L 🤝
/ @residualelectrical
I N S T A G R A M 📷
/ residualcurrent
T I K T O K ♪
vm.tiktok.com/ZM86U2jjG/
The works carried out in the video and the opinions shared are my own, and not representative of the associates and companies in the video.
This content is purely for entertainment purposes and is in no way a "how to", tutorial or educational video.
Please consult an electrician when dealing with any electrical installations.
#electricianlife #electrical #electricalengineering

Пікірлер: 42

  • @walseee
    @walseee10 ай бұрын

    Where you been, we’ve missed you 😢

  • @Jake_Baker_Electrician1997
    @Jake_Baker_Electrician199710 ай бұрын

    Not a test I have had to undertake often, so this video will be a massive help to refresh the memory in future! You’re probably the best KZread Spark for informative content that looks awesome 👌 watched all your content and I’ve adopted a lot of the things you do into my own skill set which has helped me massively as an apprentice!

  • @TheHomeent
    @TheHomeent10 ай бұрын

    Once again you nailed it. Always great videos. Full of information and the job done properly, no shortcuts.

  • @bramcoteelectrical1088
    @bramcoteelectrical10889 ай бұрын

    good to see as not many have done the 3 lead test or understand how to carry out this testing good video thanks

  • @paulstimpson8977
    @paulstimpson89772 ай бұрын

    I went with a cheaper tester as testing can be done with as you say by 3 methods, my luck get called to a TT install with a fault no power (Fuse pulled) and what looks like a disconnected Earth Rod! Didn't do the job in the end because no one knew who pulled the fuse or why and other issues! But I would have been in a pickle not being able to prove the TT earth was sound prior to the Supplier (DNO had no contact and stated that without knowing why the fuse was pulled they would not reinstate) coming out and who knows when they would turn up! Would probably need to be there when they came.

  • @fje1948
    @fje19489 ай бұрын

    Excellent video - you do thing’s properly! Many thanks Mike.

  • @corymac
    @corymac10 ай бұрын

    Great job! 👍🏼

  • @rattlehead85
    @rattlehead8510 ай бұрын

    Fantastic video mate. Good reference material to go back on as this test is not one of the common ones and not many sparks could tell you how to do it. Calculations towards the end got a bit complex with the percentage deviation but how you explained it was great. Well done fella. Enjoy your content. 👍🏻👍🏻👍🏻

  • @DarkShadowedOne
    @DarkShadowedOne10 ай бұрын

    Only just had to use this sort of tester at work this week for doing lightning protection testing. Lucky you have a nice open area to drive your test stakes in for your video

  • @sergiofernandez3725
    @sergiofernandez372510 ай бұрын

    Great explanation Mike

  • @e5Group
    @e5Group10 ай бұрын

    coming along nicely

  • @Engineer-Samibress
    @Engineer-Samibress10 ай бұрын

    Thanks for your time

  • @johnward5006
    @johnward500610 ай бұрын

    Top man! You nailed it and that's a plumber commenting!

  • @flint1982769
    @flint198276910 ай бұрын

    Great video!!

  • @tincanpete
    @tincanpete10 ай бұрын

    interesting and helpful video... thanks!!

  • @lowrybrock8272
    @lowrybrock827210 ай бұрын

    That’s really interesting stuff. And go ahead and admit it, those were your toys weren’t they? Good to see you back! Be safe out there!

  • @fredflintstone1
    @fredflintstone110 ай бұрын

    years ago I used a wheatstone bridge meter for testing earth rods in hospitals

  • @alantowler9430
    @alantowler943010 ай бұрын

    excellent video.

  • @iosebbegiashvili8145
    @iosebbegiashvili81455 ай бұрын

    previously with efli test you have almost similar readings ,i wonder ,is it worthy to do potential fall test as well?

  • @maximuspareo
    @maximuspareo10 ай бұрын

    It is ok 16 ohm ??? In my country we need 4 ohm for normal and 1 ohm for + lighting protection .

  • @adriatikkrasniqi1453

    @adriatikkrasniqi1453

    10 ай бұрын

    How did you do calculations is 2.2 percentage. To ne work out 3.8 percentage..,

  • @abdulseaforth6930

    @abdulseaforth6930

    15 күн бұрын

    @@adriatikkrasniqi145316.2/16.56≈0.98 ie 2% difference

  • @chrismason3341
    @chrismason33413 ай бұрын

    Dno or supplier still not been out to reseal?

  • @Riley_Jarvis_the_sparky
    @Riley_Jarvis_the_sparky9 ай бұрын

    Lovely video bud keep it up 👍

  • @residualelectrical

    @residualelectrical

    9 ай бұрын

    Thanks, will do!

  • @vioreltanasa988
    @vioreltanasa9886 ай бұрын

    What are you doing when you measure to a industrial place and you cannot disconnect earth because are a engine in process

  • @martijn7924

    @martijn7924

    2 ай бұрын

    Look up stakeless and selective earth testing. If money is not an issue, see earth clamp meters as well.

  • @SpikesMavic
    @SpikesMavic2 ай бұрын

    But if the test Spikes are into dry ground, what will that measure ?

  • @abdulseaforth6930

    @abdulseaforth6930

    15 күн бұрын

    Dry ground - worst case scenario

  • @electricalservicesmaroc
    @electricalservicesmaroc10 ай бұрын

    Hello man ❤❤❤🎉🎉🎉

  • @NabeelAhmad-gp5ps
    @NabeelAhmad-gp5psАй бұрын

    I haven't five years experience in this field...please guide me and help me i want work with you

  • @vioreltanasa988
    @vioreltanasa9886 ай бұрын

    You have only 1 electrode must be 3 in star connected

  • @vioreltanasa988
    @vioreltanasa9886 ай бұрын

    Rezistence should be under 4 ohms for civil and industrial ,and under 2 ohms for farming 😢

  • @adriatikkrasniqi1453
    @adriatikkrasniqi145310 ай бұрын

    I done the calculations 3.8 percentage not 2.2 percentage…

  • @fje1948

    @fje1948

    9 ай бұрын

    @adriatikkrasniqi1453 Hi. Can you please provide an analysis of your calculations - Thank you. I make it: max deviation from average 16.56 - 16.20 = 0.36 then (100/16.56) x 0.36 = 2.17% which is close to Mike’s result!

  • @adriatikkrasniqi1453

    @adriatikkrasniqi1453

    9 ай бұрын

    @@fje1948 you have to do the highest minus average taken from 3 reading then divide by the highest + - 5% but not more then that…

  • @fje1948

    @fje1948

    9 ай бұрын

    ⁠@@adriatikkrasniqi1453 Thank you for your swift reply. Using Mikes readings: Highest 16.84 - Average 16.56 ---------- 0.28 Further using your wording: ‘Then divide by the highest’ 0.28/16.84=0.01662708 ??????????? Your detailed calculations using Mikes readings would be appreciated - Many Thanks.

  • @adriatikkrasniqi1453

    @adriatikkrasniqi1453

    9 ай бұрын

    @@fje1948 than times by 100 %

  • @adriatikkrasniqi1453

    @adriatikkrasniqi1453

    9 ай бұрын

    @@fje1948 I the end of the day is good to contribute with this calculation for us as learners maybe I am wrong Mike calculation I could be right I don’t but he to explain the calculation.

  • @vioreltanasa988
    @vioreltanasa9886 ай бұрын

    I am not satisfied with this

  • @vioreltanasa988
    @vioreltanasa9886 ай бұрын

    Electrods sh

  • @picklenipples
    @picklenipples10 ай бұрын

    awesome vid!

Келесі