DIRECT SHEAR STRESS (IS-2720-PART-13-1986) Reaffirmed- 2009

Ғылым және технология

The test is carried out on either undisturbed samples or remoulded samples. To facilitate the remoulding purpose, a soil sample may be compacted at optimum moisture content in a compaction mould. Then specimen for the direct shear test could be obtained using the correct cutter provided. Alternatively, sand sample can be placed in a dry state at a required density, in the assembled shear box.
Click on link below to download the format
drive.google.com/file/d/1Raef...

Пікірлер: 82

  • @khanfahad93
    @khanfahad933 жыл бұрын

    great video sir thank you so much for sharing such precious videos

  • @HIGHWAYGUIDE

    @HIGHWAYGUIDE

    2 жыл бұрын

    It's my pleasure

  • @shaikhfazil2373
    @shaikhfazil23733 жыл бұрын

    Thank you.very nice video

  • @HIGHWAYGUIDE

    @HIGHWAYGUIDE

    3 жыл бұрын

    Thank you too

  • @amitahlawat5690
    @amitahlawat56903 жыл бұрын

    Great peace of information

  • @dharmendramishra1670
    @dharmendramishra1670 Жыл бұрын

    Very good sir, got full knowledge,

  • @HIGHWAYGUIDE

    @HIGHWAYGUIDE

    11 ай бұрын

    Keep watching

  • @anurag00100
    @anurag001002 жыл бұрын

    Thankyou so much sir ❤️❤️❤️

  • @HIGHWAYGUIDE

    @HIGHWAYGUIDE

    Жыл бұрын

    Always welcome

  • @adityasharma79228
    @adityasharma792287 ай бұрын

    to determine direct hear test we have to conduct 3 different soil specimen having same water content and same density but applying different loads like 0.5, 1 and 1.5 kg/cm^2 . correct statement hai ki nahi.

  • @rampratapmaurya2681
    @rampratapmaurya2681 Жыл бұрын

    Great sir

  • @AmitSingh-ej1ko
    @AmitSingh-ej1ko3 жыл бұрын

    Dear sir i just want to know how can i get SBC value from C and phi

  • @rishikantkol2535
    @rishikantkol25353 жыл бұрын

    Thank you sir

  • @HIGHWAYGUIDE

    @HIGHWAYGUIDE

    3 жыл бұрын

    So nice of you

  • @nitintripathi2105
    @nitintripathi21052 ай бұрын

    informative video

  • @pawanjoshi6704
    @pawanjoshi67046 ай бұрын

    Sir which type of test is this undrained consolidated undrained or consolidated drained i thik you have done undrained test but in IS code mentioned porus stone will not be used and water jacket should be provided but you have not done it please explain.

  • @sushantrauthan5704
    @sushantrauthan57043 жыл бұрын

    Very good video sir, sir what i dont understand is that how is your proving rimg reading for 0.5 kg load test 4around 46 but you have taken shear stress value as 0.37?? Is there a multiplication by proving ring constant and what is the value of proving ring constant??

  • @HIGHWAYGUIDE

    @HIGHWAYGUIDE

    3 жыл бұрын

    Please see the whole video with interest

  • @sushantrauthan5704

    @sushantrauthan5704

    3 жыл бұрын

    @@HIGHWAYGUIDE i saw it with a lot of intrest but at times i couldnt understand what u were saying

  • @varunkashyap7272
    @varunkashyap72723 жыл бұрын

    Great video. Sir which shear test is used for gravels?

  • @HIGHWAYGUIDE

    @HIGHWAYGUIDE

    3 жыл бұрын

    No idea

  • @ddcivilengineering5186
    @ddcivilengineering51867 ай бұрын

    Sir lever arm rest krna hai kya screw par... plz uska batdo

  • @DineshMalviyahere
    @DineshMalviyahere Жыл бұрын

    Very informative tutorial. I am interested to know, how we estimate normal stress i.e. for 0.5kg/cm2 the mass used is around 1.50 kg, which area we are considering to estimate 0.5 kg/cm2 ?

  • @abhijeetshukla3777

    @abhijeetshukla3777

    7 ай бұрын

    Same question from my side

  • @gauravmaru4782
    @gauravmaru47823 жыл бұрын

    Thanks a lot sir but how to find out cohession if material is cohessive

  • @HIGHWAYGUIDE

    @HIGHWAYGUIDE

    3 жыл бұрын

    Please see last part of the video.

  • @riturajdevrani1022
    @riturajdevrani10223 жыл бұрын

    Sir, the weight of dry soil taken should be 167.13 gm if not wrong, otherwise please explain how the weight of dry soil was determined?

  • @HIGHWAYGUIDE

    @HIGHWAYGUIDE

    3 жыл бұрын

    Please download the format from the link given in the description.

  • @rohitkumar-rh4qf
    @rohitkumar-rh4qf6 ай бұрын

    ❤❤❤❤

  • @manojkumar-ky1iy
    @manojkumar-ky1iy2 жыл бұрын

    Weight of wet sample will be 182.28 Dry wt.=167.1525 Water=15.1273 Please correct me if I’m wrong

  • @HIGHWAYGUIDE

    @HIGHWAYGUIDE

    2 жыл бұрын

    Thank you for your feedback

  • @marasini
    @marasini3 ай бұрын

    I have taken data of displacement in 25, 50, 75, 100 and the reading of the Proving ring 1.0, 1.2, 1.6..... how do I calculate /convert now

  • @HIGHWAYGUIDE

    @HIGHWAYGUIDE

    3 ай бұрын

    Download the excel sheet given in the description

  • @marasini

    @marasini

    3 ай бұрын

    @@HIGHWAYGUIDE shall I directly input what I mentioned or do I have to convert the unit. Did I took these two data in different Units

  • @sreenathijk2952
    @sreenathijk29522 жыл бұрын

    What is proving ring constant of shear test

  • @HIGHWAYGUIDE

    @HIGHWAYGUIDE

    2 жыл бұрын

    Please see full video

  • @krishnamoybhattacharyya2194
    @krishnamoybhattacharyya21942 жыл бұрын

    Sir please explain me that how to calculate the value of weight of wet sample required ?

  • @HIGHWAYGUIDE

    @HIGHWAYGUIDE

    2 жыл бұрын

    Already explained , please see whole video with interest.

  • @prasanthvijigeotech7894
    @prasanthvijigeotech78944 жыл бұрын

    Sir, Small Doubt the Sample thickness was 3 cm then how can you put 6 in corrected area...?. In IS Code also it was 3 and in excel you are used 60 not 6... why....??? Kindly clear my doubt....

  • @HIGHWAYGUIDE

    @HIGHWAYGUIDE

    4 жыл бұрын

    In latest revision , it is Ao(1- ẟ/6) I had divided by 60 because to convert ẟ from mm to cm.

  • @HIGHWAYGUIDE

    @HIGHWAYGUIDE

    4 жыл бұрын

    drive.google.com/open?id=1hzabyQcsBzf0Cha1O7EdLYaxo_BaW3L_

  • @nprasanthgeotech

    @nprasanthgeotech

    4 жыл бұрын

    @@HIGHWAYGUIDE Wow thank you so much for your Reply...👏👏👏 Doubt cleared....

  • @Mukthirhwar

    @Mukthirhwar

    3 жыл бұрын

    Tq I'm watched total your video sir... Small doubt Is it which type of test method sir Is it disturbed sample.?

  • @abdulraheem-ns2qg
    @abdulraheem-ns2qg4 жыл бұрын

    How did u get volume of water and maximum dry density sir

  • @HIGHWAYGUIDE

    @HIGHWAYGUIDE

    4 жыл бұрын

    See full video , you will get your answer.

  • @theconcrete8659

    @theconcrete8659

    3 жыл бұрын

    @@HIGHWAYGUIDE sir watched full video.. Didn't got the answer.. Plz tell how you took the volume of water

  • @anwarhasibuan17
    @anwarhasibuan173 жыл бұрын

    sir, how to get the LRC/Proving Ring Constant value ?

  • @HIGHWAYGUIDE

    @HIGHWAYGUIDE

    3 жыл бұрын

    Already uploaded a video

  • @simasubhadrashini2600
    @simasubhadrashini2600 Жыл бұрын

    Sir kya proving ring constant aur calibration factor same hota hai ?

  • @HIGHWAYGUIDE

    @HIGHWAYGUIDE

    Жыл бұрын

    Yes

  • @shyamugautam8470
    @shyamugautam847010 ай бұрын

    Sir undrained test, consolidate undrained test , consolidate drained test in teeno me kya difference hai kis kis condition me use krenge ye process

  • @shyamugautam8470

    @shyamugautam8470

    9 ай бұрын

    Please reply sir

  • @TrueFact266
    @TrueFact2669 ай бұрын

    Sir, Why we are take mdd 95%

  • @brahma6102
    @brahma61022 ай бұрын

    Sir isme maximum aur minimum bhi kuchh rahta hai kya please reply me

  • @HIGHWAYGUIDE

    @HIGHWAYGUIDE

    2 ай бұрын

    No

  • @simasubhadrashini2600
    @simasubhadrashini2600 Жыл бұрын

    Sir kya aap bata sakte hain ki direct shear ka stress strain curve kaise banate hain according to IS code 2720 part 13

  • @HIGHWAYGUIDE

    @HIGHWAYGUIDE

    Жыл бұрын

    Please see my last part of the video

  • @VinitModi19
    @VinitModi192 жыл бұрын

    how to get Proving ring constant value??

  • @HIGHWAYGUIDE

    @HIGHWAYGUIDE

    2 жыл бұрын

    Already posted a video

  • @vijayjha7371
    @vijayjha73712 жыл бұрын

    Sir, Please upload Triaxial shear test video

  • @HIGHWAYGUIDE

    @HIGHWAYGUIDE

    2 жыл бұрын

    I have no instrument

  • @DeepakPatel-fr8ro
    @DeepakPatel-fr8ro4 жыл бұрын

    Sir reading kaise dekhni he .. dial gauge or proving ring ki pleas btay

  • @HIGHWAYGUIDE

    @HIGHWAYGUIDE

    4 жыл бұрын

    Already posted the video.

  • @dineshkumar-sh1ew
    @dineshkumar-sh1ew2 жыл бұрын

    Sir IS code 2720 Part13 me Area Correction Formula me A(1-g/3) diya hua h

  • @HIGHWAYGUIDE

    @HIGHWAYGUIDE

    Жыл бұрын

    See latest revision

  • @patrickmaity3156
    @patrickmaity31562 жыл бұрын

    Sir how to calculate division to kg

  • @HIGHWAYGUIDE

    @HIGHWAYGUIDE

    2 жыл бұрын

    Use calibration factor

  • @soumyabaral4743
    @soumyabaral47432 жыл бұрын

    Sir plz provide calculations of cohesion and angle of internal friction.

  • @HIGHWAYGUIDE

    @HIGHWAYGUIDE

    2 жыл бұрын

    Already provided

  • @soumyabaral4743

    @soumyabaral4743

    2 жыл бұрын

    @@HIGHWAYGUIDE Sir, after plotting graph some doubt came in calculations.

  • @sanir87
    @sanir87 Жыл бұрын

    Sir ji where it is mentioned to rate of speed is 1.25 mm

  • @samalfamily4414

    @samalfamily4414

    Жыл бұрын

    In the standard

  • @saurabhgujjar4445
    @saurabhgujjar44452 жыл бұрын

    Sir correct area kaise nikalte hai

  • @HIGHWAYGUIDE

    @HIGHWAYGUIDE

    2 жыл бұрын

    Please see full video

  • @patrickmaity3156
    @patrickmaity31562 жыл бұрын

    Sir can you send me Excel sheet please .

  • @HIGHWAYGUIDE

    @HIGHWAYGUIDE

    2 жыл бұрын

    Please see my full video you will get your answer

  • @dineshkumar-sh1ew
    @dineshkumar-sh1ew2 жыл бұрын

    But AApne A(1-g/6) Lie h mai ye nahi samajh Pa raha hu

  • @HIGHWAYGUIDE

    @HIGHWAYGUIDE

    2 жыл бұрын

    drive.google.com/file/d/1hzabyQcsBzf0Cha1O7EdLYaxo_BaW3L_/view

  • @HIGHWAYGUIDE

    @HIGHWAYGUIDE

    2 жыл бұрын

    I have given the link download the latest revision

  • @pawanjoshi6704

    @pawanjoshi6704

    6 ай бұрын

    Sir which type of test method is this I think undrained because you choose rate of strain as 1.25 mm / min but in IS code mentioned that in undrained condition porus stone are not used and water jacket should be provided but you nave not done that i have a doubt kindly clear it sir my water jacket is not provided

  • @user-wg1cd6zj1o
    @user-wg1cd6zj1o3 жыл бұрын

    pleas sir attach excel sheet

  • @HIGHWAYGUIDE

    @HIGHWAYGUIDE

    3 жыл бұрын

    Already attached

Келесі