Common Rheem problem, locked out for no clear reason. Board or sensor?

Found condenser locked out on low pressure. Started system, and there were no pressure problems. #hvac #hvaclife #fieldpiece #ruud

Пікірлер: 133

  • @HVACGUY
    @HVACGUY2 жыл бұрын

    I’ll try to make sure I post a video if I can zero in on exactly what was causing this.

  • @Bryan-Hensley

    @Bryan-Hensley

    2 жыл бұрын

    Are you positive it wasn't a hp lockout? I couldn't see the flashes. It's really common for Rheem to hp lockout at the beginning of heating season. 60 plus outside temperature with low airflow will do it. Clogged air filter, dirty clogged evaporator or fan motor.

  • @999raiderz

    @999raiderz

    2 жыл бұрын

    If I would have seen that high of pressure on low side, I would have checked amps. With the 77 degree inside temperature it seems that the pressure would have been lower. I thought just from pressures it may have been a bit overcharged. If capacitor ( if it was a psc) was weak on blower motor…that could have led to a low pressure situation by lowering fan speed. Did you figure out why it was faulting?

  • @jaymz0074

    @jaymz0074

    Жыл бұрын

    Did you happen to figure out the cause?

  • @louis_costa

    @louis_costa

    Жыл бұрын

    Did the new board fix the issue?

  • 6 ай бұрын

    thank so much for ur info, on this board. I will try to see, what i can do to get this going base on ur info. Thnx@@Bryan-Hensley

  • @williamholley1232
    @williamholley12322 жыл бұрын

    You do a really good job explaining what your doing and thank you very much for all the tips. Keep the videos coming 😀

  • @jonathanweatherman934

    @jonathanweatherman934

    2 жыл бұрын

    Xhjcjffjhcucjficofj

  • 6 ай бұрын

    if ur a tech, i guess, because i am trying hard to figure out what he doing, but it will take quite a few more sessions.

  • @luckybeltz3892
    @luckybeltz38922 жыл бұрын

    Awesome video I learn so much watching them thank you!!

  • @YukonHawk1
    @YukonHawk12 жыл бұрын

    Great job diagnosing the issue.

  • @mance7996
    @mance7996 Жыл бұрын

    Thank you for the video,I mostly work on Goodman and Carrier,still getting knowledge from people like you.. this video is awesome,so many tips if you pay attention(I watched the video multiple times):))).. thank you sir and keep posting !.. you have one more subscriber !

  • 6 ай бұрын

    he is good, and i really give him thanks..but you have to be a hvac tech, to understand what he is doing, i am not, but i am trying hard to get his teaching.

  • @lookgd
    @lookgd Жыл бұрын

    11:00 my OAT sensor was faulty/ I had both Fault Lights on hard. ...yessss the bypass! it was enough to get it going until the Board and Sensor Kit from ProTech can be ordered (in 5 days) ...your videos are a Goldmine to the Trained Eye 🐉

  • @flamaest
    @flamaest2 жыл бұрын

    Wow, those refrigerant measuring instruments that connect to your phone are interesting. Everything seems so much more compact than it used to be.

  • @mance7996

    @mance7996

    Жыл бұрын

    Yes,probes are the future of HVAC business .. I love them and Fieldpiece is the best in my opinion .. I’m using their tools and probes are next on my list to add to my tools..

  • @brianberg1284
    @brianberg12846 ай бұрын

    Ran into tho exact same problem however it was not a bad board…the txv in the condenser had a restriction and when the customer put it into heat it pulled a vacuum and tripped the low pressure switch enough times to cause the lockout

  • @nottmore
    @nottmore Жыл бұрын

    Hey man just wanted to say thanks saved me a trip from the hvac guy.

  • @Eddy63
    @Eddy632 жыл бұрын

    Nice job ... Thx for sharing ...

  • @QSSCEO
    @QSSCEO Жыл бұрын

    Sand the tubing before putting on the clamps....Good tip on the LPS with the meter ! Possibly intermittent indoor ECM module/ no start.

  • @caru3257
    @caru32572 жыл бұрын

    on Wednesday I had a condenser unit that would not start. The code was locked out on pressure. I went to touch the compressor but it was cold so I put on gauges and the charge pressure seemed ok. I was going to test the cap when I notice my common from the board was burned out. I had it running for 15 minutes and took an amp reading and called a day.

  • @techfive7202
    @techfive72022 жыл бұрын

    I get these calls all the time after a storm but its always high pressure lockout. I install a surge protector on the air handle and one on condenser. Does the trick.

  • 6 ай бұрын

    A surge protector, what is that, how does that works, on rheem units.

  • @The1realro

    @The1realro

    3 ай бұрын

    Never even heard of thatn

  • 4 ай бұрын

    what did you do to the pc board to make it start up? I saw you touch and jumped something up top, but ur not saying what u did. This is great info to start up a unit when it is in lock out mode. What did you jumped?

  • @senorgringolingo

    @senorgringolingo

    2 ай бұрын

    I'm pretty sure that he said he jumped/shorted the two test pins, which resets the lock-out code. This is written on the board, just below the table that explains each board status.

  • @lancelawrence3259
    @lancelawrence32592 жыл бұрын

    Nice work

  • @kjjr7795

    @kjjr7795

    2 жыл бұрын

    Curious was it a nest tstat?

  • @s.c.588
    @s.c.588 Жыл бұрын

    The board, pressure switch, depending on the type thermostat loosing G will cause that, the air handler circuit board loosing G and a failing evaporator motor/and or capacitor if it has one. And also bad relays for the evaporator motor if it’s a PSC motor and running off a relay instead of a board if it’s an older unit. But most have all of course switched to circuit boards long ago. But if it’s an indoor issue with the blower motor or it cutting off the coil of course would be iced up. And there are other issues that will cause that problem as well but they are rare. I’ve had some to drive me nuts before i found it. Expansion valves shutting closed are a rare occurrence but will cause that.

  • @leehare9233
    @leehare92332 жыл бұрын

    Been on several with same issue. You can install a bypass timer (ICM 175B) for the low pressure switch .

  • @HVACGUY

    @HVACGUY

    2 жыл бұрын

    I didn’t know of this timer

  • @Emmettaug

    @Emmettaug

    2 жыл бұрын

    Please explain the bypass timer I am interested in this modification. Thanks

  • @Genesis38T
    @Genesis38T Жыл бұрын

    I have the rheem 13pjl24a01… at the top of your board I notice your red is connected above brown… I don’t have a red plugged in but have a rogue red wire that looks out of place… should a red wire be connected? What I thought was a bad capacitor, still didn’t solve the issue, just hums with no motion.

  • @realsthvac7942
    @realsthvac79422 жыл бұрын

    I have this problem a lot high pressure always has me out but pressures are good

  • @610610billy610610
    @610610billy6106104 ай бұрын

    I have this same problem. Low pressure switch open on a rp1436aj1na. I'm hoping it's something simple. We just had the condenser coil replaced last winter due to ice damage, and im hoping it didn't freeze up again and grenade itself.

  • @MariosACandRefrigeration
    @MariosACandRefrigeration2 жыл бұрын

    could be moisture,but most likely lps,you can put temporary lps at service port.tricky one.

  • 6 ай бұрын

    Could you say what terminals ur testing, what reading ur getting, is the unit on or off as you make ur tests, what ur expecting etc etc, it would be a great help. thnx.

  • @Ggg77777
    @Ggg777772 жыл бұрын

    Lennox does the same. I always change the defrost control board , and seems to take care of problem so far

  • 6 ай бұрын

    are lennox and rheem unit functions the same? i.e. on the voltage to turn bring on the compressor in the selected modes? How do can you tell which LED is #1 or which is #2? My rheem unit has the top LED flashing and the bottom one off. What does that mean? do you know? thnx.

  • @senorgringolingo

    @senorgringolingo

    2 ай бұрын

    Read the text on the board. The LEDs are labeled, and there's a small table that explains what each code means.

  • @sknight0391
    @sknight03912 жыл бұрын

    I'm going with a squirrely x13 or that stupid blower relay they use that's like the Goodman relay. I've replaced a couple of those. There was water gurgling in the drain trap, that could have possibly been from ice melt? On the flip side of that, I had a unit freeze the entire coil into a block of ice and the entire line set and all the way out to the compressor and the unit was still running and did not trip low pressure. 😵😵😵

  • @jasonnorrie3834

    @jasonnorrie3834

    6 ай бұрын

    I see that a lot from multiple brands. What the heck is going on.

  • @senorgringolingo

    @senorgringolingo

    2 ай бұрын

    Did you figure out that frozen unit's problem? Was it a malfunctioning TXV?

  • @MichaelSmith-pg6gi
    @MichaelSmith-pg6gi9 ай бұрын

    That gurgling noise is driving me crazy!!!!

  • @tedhicks5431
    @tedhicks54312 жыл бұрын

    I have found 2 unit do that 1st one I just ran pigtail from common to one of contactor ran fine customer never called me back on replacing defrost board either he called someone else or its still running thats been 4yrs .

  • @NASHHOTCTV
    @NASHHOTCTV2 жыл бұрын

    THE JAMES BOND OF HVAC.

  • @jakesteel3641
    @jakesteel364111 ай бұрын

    Hazah!!! For anyone looking after you clear your fault (changing filters etc) jump the two pins at top left of your board to reset it and see if it trips again.

  • 6 ай бұрын

    which i could tell what did from this video, i am having the issues on my rheem unit, but is not able to follow here. thnx still.

  • @97Napkins
    @97Napkins2 жыл бұрын

    I'd prob just bypass low pressure switch. Does it again it's definitely the board. Come back out and frozen or not cooling. Then it's blower or txv...very rare issue would be a closed evap circuit. Slowly freezes up after day or two.

  • 6 ай бұрын

    how do u do that?? BYPASS LOW PRESSURE SWITCH. we are all not techs, or mechs. It would be nice if when ppl say things, they would tell the procedure or give an idea of how it is done.

  • @The1realro

    @The1realro

    3 ай бұрын

    Go to HVAC school man you expect professionals to explain what we learn in years of school and exp in a KZread comment.

  • 3 ай бұрын

    @@The1realro You are of the "CRAB" generation. And thats ok, we have learnt enough about ur kind,. But try to see the good that good people do. IT may help, to be a better person, eerr, CRAB.

  • @The1realro

    @The1realro

    3 ай бұрын

    Lol shut up man you are a bird and it doesn't matter what generation you are from. I'm 29 with 6 years of HVAC knowledge and still so much to learn but we have to be resourceful. You can easily search up how to bypass LP switch instead of begging a stranger for answers. Mind you, the stranger isn't even the maker of the video.

  • @TheCyleRitchie
    @TheCyleRitchie2 жыл бұрын

    Curious as to what the problem was. Mine has started giving me the LP lockout.

  • @PaulZ154
    @PaulZ1542 жыл бұрын

    Possible issue with the x13 blower intermittently cutting out causing the low pressure? I hate intermittent issues like that

  • @HVACGUY

    @HVACGUY

    2 жыл бұрын

    Yes, that’s true.

  • @Bigsteve123
    @Bigsteve1232 жыл бұрын

    The rheems are very sensitive to power glitches. A lot of times you never even know the power even glitched but it will definitely lock that board out. I have to do this to mine at least twice a year, even when it was brand new.

  • @CharlesEllsworth89

    @CharlesEllsworth89

    Жыл бұрын

    What exactly you have to do? Same problem

  • @Bigsteve123

    @Bigsteve123

    Жыл бұрын

    @@CharlesEllsworth89 If it seems to do this more often just replace the defrost board, but like mine it’s only done this 3 times. A lot of people are saying it’s low or high pressure sensors but everything on mine led me to believe it’s just minor power glitches in the HOA neighborhood. Those boards are just sensitive. Just reset it and see how long it goes.

  • 6 ай бұрын

    how do you RESET this board? please@@Bigsteve123

  • @Bigsteve123

    @Bigsteve123

    6 ай бұрын

    Take a screw driver and touch the two pins that say test on the defrost board while in cool mode or just simply turn breaker on and off for air handler. That will reset your low voltage.

  • 6 ай бұрын

    thank you much. will do one or the other.@@Bigsteve123

  • @ApartmentMaintenancePOV
    @ApartmentMaintenancePOV6 ай бұрын

    These Ruud/Rheem units are very problematic when it comes to the defrost board. They’re constantly going on high or low pressure lockouts for no apparent reason.

  • @adamcraig1568
    @adamcraig15682 жыл бұрын

    Thanks for the video. So LPS, defrost Board, Blower failure, TXV is our options lol. Let us know what happens. I’m leaning toward blower. I’d bypass the switch and board and if it actually freezes up than it’s gotta be the blower. TXV’s usually don’t unstick. If a while passes with no issues than at least we know the issue 🤪 by that time you’ve spent too long lol hate intermittent issues!

  • @throttlebottle5906

    @throttlebottle5906

    2 жыл бұрын

    but moisture in the system could ice the txv.

  • @robertocarrillo7430
    @robertocarrillo743010 ай бұрын

    My customer has a similar issue the compressor nor motor turn on it is on trip/lock may be similar issue. 4 ton gas pack

  • @searcy95
    @searcy952 жыл бұрын

    I'm getting a high pressure lock out, pressures look good. Unit (HP) will start up and shut off in 30 seconds

  • @John..556
    @John..5562 жыл бұрын

    It’s the control board I had a subdivision with all rheem units. Multiple calls to diff houses rheem supplier told me they were defective and he had been swapping them out all month

  • @Chainsaw600

    @Chainsaw600

    Жыл бұрын

    I’ve got 2 units at a house right now with similar issues. One has a chattering, arcing contactor that blows the 3 amp fuse and one that says it’s in lockout due to low pressure. Reset the board and it shows low pressure again despite low pressure testing ok. I’ve ordered defrost/control boards for both. Hope I’m on the right track.

  • @BarBlocs
    @BarBlocs29 күн бұрын

    How much did it cost for the defrost control board

  • @richardtoolman1
    @richardtoolman1 Жыл бұрын

    Question. What wires did you touch with the screw driver to jump the lock out out

  • @wallytanss97

    @wallytanss97

    Жыл бұрын

    Test lead together

  • @The12stonesfan
    @The12stonesfan2 жыл бұрын

    Just out of curiosity, how common are Heat pumps? I've always heard of them but never seen one with my own eyes because nobody I know has one, and I live in Louisiana which is an area that is considerd good for a heat pump system but like I said I've never seen one.

  • @HVACGUY

    @HVACGUY

    2 жыл бұрын

    They are about 50% of my calls

  • @Bryan-Hensley

    @Bryan-Hensley

    2 жыл бұрын

    Heat pumps are 99% of my calls and installs. I've been working on them since 1988. I live in East Tennessee

  • @hughholt121

    @hughholt121

    2 жыл бұрын

    Very common in Central Florida. Both air to air and water to air heat pumps. They were in use when I began the trade n 1963.

  • @denrayr
    @denrayr2 жыл бұрын

    What a stupid design. The control should resume operation automatically once the fault condition clears. Do you think they might have had a dirty filter? What do you think about jumping the lps circuit on the board, then rewiring the lps to be in series with the yellow wire input to the condenser? This way you'll eliminate nuisance lockouts while maintaining the ability to cut out during a low pressure condition. If the board locks out while bypassed, then you know the board is at fault. If you have some other intermittent issue, it will eventually get worse, so it can be identified.

  • @graymodeler
    @graymodeler2 жыл бұрын

    Sounds like a stopped up gutter dripping on the turnout. I had to fix one by my bedroom so I could sleep!

  • @chrissipple1018
    @chrissipple10182 жыл бұрын

    what is a splitter

  • @1martinontherocks
    @1martinontherocks Жыл бұрын

    The carrier infinity communicating defrost board is the most full of enigmas

  • @aarongunter5582
    @aarongunter55822 жыл бұрын

    What is that bubble sound

  • @elirick09
    @elirick0918 күн бұрын

    I touched the red with the brown 😔 now I can’t find the fuse

  • @buddweiser4457
    @buddweiser44572 жыл бұрын

    What’s the price for Evap coils now days 🤔

  • @sh2697
    @sh2697 Жыл бұрын

    IF I can ask you. My parents church have a RP1460AJINA. When I press the contactor, it just CLICKED. Nothing. I replaced the contactor and the cap. Still the same. I get 240V to L1 and L3. But I replaced the contactor anyway. I would start with no trouble codes but after I press the contact and CLICK, I would get a trouble code. some type of flash but I gave up after 2 hrs. Any suggestions?

  • @sh2697

    @sh2697

    Жыл бұрын

    I t looks like my church board is like yours...did you jump/short the E1? Should I try that too? With the power on?

  • @sh2697

    @sh2697

    Жыл бұрын

    What should I read at the board for LPressure and H pressure?

  • @hughholt121
    @hughholt1212 жыл бұрын

    Breaking the Hi and Low pressure switches with the red wire and the defrost board with the common seems like asking for trouble .

  • @HVACGUY

    @HVACGUY

    2 жыл бұрын

    Just until I get back.

  • @yalman32
    @yalman32 Жыл бұрын

    I begin to develop a hating relationship with these unti😅

  • @kjjr7795
    @kjjr77952 жыл бұрын

    Curious was it a Nest tstat?

  • @HVACGUY

    @HVACGUY

    2 жыл бұрын

    No, it was a Honeywell

  • @leiferickson713
    @leiferickson71311 ай бұрын

    I’m looking to replace my 34-year-old Rheem. And I sure don’t want that condenser. Just to say I’m electrician and I have stocked the cap and the contactor for mine. And it’s never went out lock I don’t know. And it sucks that I have to do so because they’re all made like crap now.

  • @cthorn8355
    @cthorn8355 Жыл бұрын

    422b?

  • @jkbrown5496
    @jkbrown54962 жыл бұрын

    Does the LP lock out require resetting the board or will it auto-clear? My HP switch developed a resistance across it last Spring. Initially, diagnosed as a bad board because of flash code confusion between the comfort alert (on schematic) and the board flash code (on a sticker at far extreme from schematic). I doubted the diag so tested the pressure switches and found the HP had about 15 ohms across it going up to 30 when running where it shut off. Oddly, the unit would work from sundown till a couple hours after sunup. Long story short, they came with a board and HP switch, confirmed and changed the HP switch. Small hairline crack was found on the switch. With the recent AT temp changes could there be a hairline crack in the LP switch that opens when it gets colder? Might be worth changing the LP switch is cheap for the customer. Or put your meter on the switch then chill it somehow. I had a similar issue with my internet. Twice a year or so it would get sketchy but for several years they found nothing except that it couldn't handle the higher speed service. Then one year, the tech found a cracked insulator at the pole that would get pulled open when it was colder and windy.

  • @HVACGUY

    @HVACGUY

    2 жыл бұрын

    I believe I’m heading back tomorrow I can check then

  • @coolramone

    @coolramone

    Жыл бұрын

    I don’t think the board will auto clear. Reset the board by d/c the low voltage to it. What it looks like he did was short the R C which would interrupt current to the board and reset it.

  • @pedros.c6742
    @pedros.c67422 жыл бұрын

    Hi what u touch with the screwdriver? To turn on ??

  • @HVACGUY

    @HVACGUY

    2 жыл бұрын

    Little pins on the board labeled “test”

  • @nelsonmontalvoperez7017
    @nelsonmontalvoperez7017 Жыл бұрын

    Bad contactor. Check coil. Causes a voltage drain and gets stuck flashing pressure switch wont start condenser

  • @jorge2897
    @jorge28972 жыл бұрын

    how to you charge system with those gauges?

  • @jonathandk5

    @jonathandk5

    Жыл бұрын

    Bluetooth

  • @henryoo7672
    @henryoo7672 Жыл бұрын

    My heat pump is blowing but not hot air. Why? Is it about gas? I have no gas tank. I don't see control unit?

  • @henryoo7672

    @henryoo7672

    Жыл бұрын

    Do you test with 0 energy?

  • 6 ай бұрын

    maannn i wish you would say what ur doing, or describe what ur doing as ur doing it. it would be a lot more helpful to the people who come ur channel. I have a rheem unit that is giving the same issue, as this one here, but i did not get anything much from you here, because you are not talking or saying what you are doing as you are doing it. But thnx still i will try harder to see what i can gather from you. it will be a challenge though.

  • @Johnnyreengo

    @Johnnyreengo

    18 күн бұрын

    If you need more explanation than what he provides then you might reconsider doing the work yourself

  • @97Napkins
    @97Napkins2 жыл бұрын

    Bet it's a Sticking TXV.

  • @98red300
    @98red3002 жыл бұрын

    Was that a 16 seer condenser?

  • @HVACGUY

    @HVACGUY

    2 жыл бұрын

    14

  • @jeffreywhitlatch1409
    @jeffreywhitlatch14092 жыл бұрын

    Oh the stress.

  • @boggy7665
    @boggy76652 жыл бұрын

    WHAT is that bubbling brook noise?

  • @HVACGUY

    @HVACGUY

    2 жыл бұрын

    The drain. The p-trap was right next to me, and it was nearly dry after I vacuumed it out. The air handler was pulling air through it.

  • @stephwaylonwells3218
    @stephwaylonwells32182 жыл бұрын

    👍

  • @brianfoughty9006
    @brianfoughty90062 жыл бұрын

    This is one reason I can’t stand rheem. A cabin rental facility that my company now services has all rheem equipment and every summer we will go back to the same units 2-3 times ( of course in the middle of the night half the time) and reset the high pressure lock out. All units are good on charge coils are clean blowers are working filters clean and blower wheels Are clean.

  • @crites123456789
    @crites1234567892 ай бұрын

    Mines blinking just like that. Did everything in this video and still can't get it to kick on. Furnace in basement is on but this pos won't start

  • @wes2460
    @wes24602 жыл бұрын

    I think I have the same unit and its been a pain in the ass, they are the loudest heat pump. With that steep angle two blade fan spinning at 1075Rpm. Most twin blade fans spin at 825 so you don't get that chop chop pulsation. My old 1989Rheem heat pump was so quite you could barley hear it and it lasted forever. Now I am in hell I cant sleep in my bedroom cause it keeps me up. They don't heat worth a shit now also. The old heat pump would heat it felt really warm this is just cold air . I am going to have to Rip out that outdoor unit and put a Mr Cool Universal outside I bought at a scratch and dent . I will never buy another Rheem.

  • @leiferickson713
    @leiferickson71311 ай бұрын

    They just keep making shit more complicated. What’s wrong with just the And the contactor. I suppose there’s no money in that.

  • @Paulie1232
    @Paulie12322 жыл бұрын

    Me, I'd rip that board out and rewire the whole unit...

  • @97Napkins

    @97Napkins

    2 жыл бұрын

    For? What reason? 🤔

  • @Brad.W
    @Brad.W2 жыл бұрын

    I know whats wrong with it!! Its a Rheem!!! If you go Rheem you get reamed. I worked for an HVAC contractor couple years ago over a summer, 7 out of every 10 units we replaced was a Rheem the other 3 was either Lenox or Ruud systems..

  • 17 күн бұрын

    YEah I agree, Rheen units sucks, My 2yrs unit has a leak at a soldered joint, and the tech says it is a real common issue with RHEEM. Why cant they SOLDET THESE JOINS PROPERLY, ON THE HIGH SIDE that has THE HIGH PRESSURE SWITCH. DO they care about their name?

  • @thedirtysouth4980
    @thedirtysouth4980 Жыл бұрын

    Prob a stupid X13!

  • @naterhishmeh850
    @naterhishmeh850Ай бұрын

    Bad contactor

  • @mattmoore2036
    @mattmoore2036 Жыл бұрын

    Can’t watch this one. That noise is to damn annoying.

  • @realestateservicessaleshea99
    @realestateservicessaleshea992 жыл бұрын

    Check the indoor fan on that Goodman? Nice field hack👍🏻 🥃🥃🍺🍺🍺🍇🏌🏻‍♀️ Stay safe. Retired (werk'n) keyboard super tech. Wear your safety glasses!

  • @HVACGUY

    @HVACGUY

    2 жыл бұрын

    It’s a matching 3 year old Ruud

  • @realestateservicessaleshea99

    @realestateservicessaleshea99

    2 жыл бұрын

    @@HVACGUY just kidding 😂 I thought only Goodman's needed work😅🤣😉👍🏻