Cheap & Easy Way to Connect a Generator to Your House - Legal Too!

Тәжірибелік нұсқаулар және стиль

For $100 you can connect your generator to your house legally & safely WITHOUT backfeeding dangerously. See how I installed mine start to finish. This works for gas generators or battery systems usign 240v to run things like heating systems,, well pumps and more.
Generator Inlet: amzn.to/4asBIHt or amzn.to/3HcYCoZ
Wire Strippers: amzn.to/3vaVeIt
Interlock Kit (Square D): amzn.to/41uACqB
10/3 Wire: amzn.to/3GQRluL or amzn.to/3tBX9oJ
Nothing in this video was sponsored - Electric work is NOT for everyone. This video is only for entertainment purposes and can't be a duplicate for a professional and your setup may be completely different and your town or county may have different electric codes.
As a member of the Amazon affiliate program I earn commissions on sales using links in this video
Disclaimer:
Due to factors beyond the control of Silver Cymbal, I cannot guarantee against improper use or unauthorized modifications of this information. Silver Cymbal assumes no liability for property damage or injury incurred as a result of any of the information contained in this video. Use this information at your own risk. Silver Cymbal recommends safe practices when working on machines and or with tools seen or implied in this video. Due to factors beyond the control of Silver Cymbal, no information contained in this video shall create any expressed or implied warranty or guarantee of any particular result. Any injury, damage, or loss that may result from improper use of these tools, equipment, or from the information contained in this video is the sole responsibility of the user and not Silver Cymbal.
EASY Way To Connect A Generator To Your House - Interlock Inlet Install

Пікірлер: 216

  • @SilverCymbal
    @SilverCymbal5 ай бұрын

    Tools from the video: Generator Inlet: amzn.to/4asBIHt or amzn.to/3HcYCoZ - Strippers: amzn.to/3vaVeIt Interlock Kit (Square D): amzn.to/41uACqB 10/3 Wire: amzn.to/3GQRluL or amzn.to/3tBX9oJ

  • @jamesborton9237
    @jamesborton92374 ай бұрын

    Having installed many of these, AND consulting customers, the BEST course of action is ... Only install 6/3 wire from inlet box to breaker panel, someday you will want to UPGRADE to a larger generator (50 amps) (electric start) making it easier for a spouse or kids to facilitate the starting of the generator if you're not home when emergency arises. Always put inlet box OUTSIDE allowing plenty distance AWAY from house (windows, vents etc ) also consider installing an outdoor 120 volt service box (receptacle) to charge your generators starting battery BEFORE THE STORM hits. TYPE OUT IN LARGE letters an instruction sheet so ALL family members can follow procedures to start generator. Have flashlights strategically located to start generator IN THE DARK. Keep FRESH fuel supply in stock , plus oil change, air filter and spark plugs WITH dedicated tools on site . Do you want to go shopping at 3 am in an ice storm for a spark plug to start a generator to keep your furnace on ? (Or send the spouse 😅 ? )

  • @johnnyhotrod

    @johnnyhotrod

    Ай бұрын

    Excellent preparedness tips! Thank you

  • @tylerfoss3346
    @tylerfoss33465 ай бұрын

    I had a licensed master electrician wire a similar interlock and generator feed line to my main electrical circuit breaker box years ago. I consider it some of the best money I have spent on improving my home. I have not needed to do this many times (few power outages, thank God) but it is pretty awesome to run my entire home off the generator in an emergency. Thank you for another wonderful video!

  • @SilverCymbal

    @SilverCymbal

    5 ай бұрын

    That is awesome, I am amazed at how many people rig unsafe stuff. These things will last longer than the next 20 iphones thAt are released. Money well spent.

  • @infiltretor287

    @infiltretor287

    5 ай бұрын

    What did he charge you for something like this?

  • @tylerfoss3346

    @tylerfoss3346

    5 ай бұрын

    @@infiltretor287 it was supposed to be $200 but I believe he charged me $400. That included the 20 foot of cable to hook up the generator to the house. Worth it to me. No regrets.

  • @sam.p12345

    @sam.p12345

    5 ай бұрын

    ‘Licensed master electrician’; christ! In that case I was served by a licensed master chef at McDonald’s yesterday.

  • @camerontechstuffs

    @camerontechstuffs

    4 ай бұрын

    lol what? master electricians arent just something they call themselves... Its alot of work and takes many years to obtain the title. @@sam.p12345

  • @TheStevedie
    @TheStevedie4 ай бұрын

    I always flip all the breakers off on my sub panel and I have the breaker on the generator turned off as well. I go out and start the generator, flip the breaker on after about 30 seconds. Then by the time I get inside I can start flipping breakers on one by one. Great video overall for someone looking to do this too.

  • @claudenormandeau9211
    @claudenormandeau92115 ай бұрын

    When we built our house we had the electrical contractor wire in a transfer switch. Nice and safe that way and relatively cheap while your doing new construction

  • @SilverCymbal

    @SilverCymbal

    5 ай бұрын

    That was a great idea. It adds almost nothing when building new, but you have to know to ask! Good move for you gyuys

  • @fredinathan6960
    @fredinathan69605 ай бұрын

    I have no idea why I love watching your videos.

  • @SilverCymbal

    @SilverCymbal

    5 ай бұрын

    Thanks for watching

  • @robertmunroe3976
    @robertmunroe39765 ай бұрын

    Well done Silver. I did the exact job a year ago after watching more than a dozen different KZread videos; mine is below the main panel but on the outside of the house. The beauty of your video is that it’s a “one stop shop” of everything needed to safely install the inlet box. Thanks for all the help; I always find value in your videos!

  • @SilverCymbal

    @SilverCymbal

    5 ай бұрын

    I really appreciate that and am pleased the video was helpful.

  • @user-st6zc7us6o
    @user-st6zc7us6oКүн бұрын

    I just bought a Batteryevo Arctic. 15.5 kwh capacity. It comes with 2 cables to connect it. One for power into the battery, the other for power out of the battery. The battery is connected between the main panel and a sub panel with the circuits to be backed up. One of the cables can be used to connect the main panel to the sub panel if the battery is removed.

  • @Tota-ct4qi
    @Tota-ct4qi7 күн бұрын

    Only video that actually explains everything good job brother

  • @simongchadwick
    @simongchadwick5 ай бұрын

    I can't believe how clean and tidy your Rachio sprinker control wiring is. Oh, and thanks for the bit about the interlock installation. Merry Christmas to you and yours Chris!

  • @ES-iz4wf
    @ES-iz4wf5 ай бұрын

    We built in 16’ and had our electrician install an interlock switch in our breaker panel and a 30 watt outlet on the back outside wall of the garage. I keep my portable generator in my shed which is just a few feet from my garage so it makes it easy to get out and set up. I haven’t had to use it yet but it’s there if I do. I have a maintenance schedule for my power equipment which includes firing up the generator to ensure it works when called upon.

  • @edover50
    @edover505 ай бұрын

    Good video as always Chris. I live in a region that rarely has power outages but find the info fascinating.

  • @gregmgm06
    @gregmgm065 ай бұрын

    Very nice. I plan to do the same on our new house eventually so it's great to see how it all goes together. Thanks for the video!

  • @joebob227
    @joebob2275 ай бұрын

    Great video! I did the same for my house, but you should address the generator you're using for this setup. It has to be a floating neutral one vs bonded neutral if you're not also disconnecting the neutral leg from utility (very rare). Most generators there is a way to unbond it, and there are warning stickers you'd need to label the inlet and generator to be within code.

  • @RocketUsa
    @RocketUsa5 ай бұрын

    I got this done last year and it works great

  • @PeriWan-um4hw
    @PeriWan-um4hw5 ай бұрын

    What an amazing video!! Hope 2024 brings you and your family an abundance of joy and wonderful things!! ❤

  • @leadfarmer73
    @leadfarmer735 ай бұрын

    This was simply beautiful work my friend. Best video on this on KZread. Guava ✌🏽

  • @SilverCymbal

    @SilverCymbal

    5 ай бұрын

    Much appreciated! I love your channel a lot I have watched a lot of your stuff!

  • @calvie5551
    @calvie55514 ай бұрын

    Great explanation of how to connect this to my house, thank you very much!!!

  • @michiganman845
    @michiganman8455 ай бұрын

    I had this done last year. Cost me about $1200. They did have to drill thru exterior wall and run the lines to my garage. It was well worth the money spent.

  • @ohiosigmarizzler344
    @ohiosigmarizzler3445 ай бұрын

    everything looks so clean and well done

  • @SilverCymbal

    @SilverCymbal

    5 ай бұрын

    Thanks so much! 😊

  • @david-holmes
    @david-holmes5 ай бұрын

    Great work as always! I'd love to see one on how to deal with Multi-Wire Branch Circuits (shared neutrals) using a 120v power source powering both legs of a panel.

  • @SilverCymbal

    @SilverCymbal

    4 ай бұрын

    Thank you for the kind words and generosity!

  • @jeffryan590
    @jeffryan590Ай бұрын

    Great video!!! Glad to see the Generator Interlock installation - it is VERY important to have & will save lives. (maybe yours) In most cases, your generator will NOT be able to power your entire house. Before you actually have to run Generator power, Identify which Circuit breakers are your 'Essential' ones (Furnace, Well Pump, Fridge, Freezer, essential lights, etc) I used a green paint marker to mark these breakers. Next, I marked the 'Nice to have' breakers (garage door opener, more lights, outlets for TV, etc) - I used a yellow paint marker. The remaining go unmarked & are things that take high amps, like the Range, Electric Water Heater, A/C, Electric Dryer, Washing Machine, dish washer, etc. Monitor your Amp gauge on your generator. You can run your Range if you turn off some of your Essential breakers. Making a Checklist & instructions on 'How to' get everything working, in the proper order is good to have. Make sure you have a working flashlight available. You will have to get this working in the most inconvenient time & conditions. Make sure you start & run your generator every 30-60 days to insure it starts & runs. Keep an extra quart of oil available & rotate your gas. Do a full test at least once a year. (nothing worse than to have a generator that wont start of run when you really need it) For extended power outages (several days or longer expected) - run your generator for about 1 hour, then shut it down for about 2 hours (or more, based upon your conditions). This will allow your limited fuel supply to last longer.

  • @AnAZPatriot
    @AnAZPatriot4 ай бұрын

    I installed a subpanel with 3-way rocker switches right underneath the breaker box. 1 position is fed from the generator, one position is not fed at all, and the other position is fed from the street. That way the generator and the street will always remain separated.

  • @PeaceChanel
    @PeaceChanel2 ай бұрын

    Thank You Francie for All that you are doing for our Planet Earth.... Peace.. Shalom.. Salam.. Namaste 🙏🏻 😊 🌈 ✌ ☮ ❤

  • @jdthewelder8308
    @jdthewelder83085 ай бұрын

    Excellent presentation.

  • @Mixwell1983
    @Mixwell19835 ай бұрын

    Did this install last year with my westinghouse 3600w. Make sure the generator neutral isnt bonded when doing this. You can only have 1 bonded neutral in a circuit

  • @robshandl3

    @robshandl3

    4 ай бұрын

    Can you please explain that in simplest terms for us simple folks?

  • @rM-wf3yk

    @rM-wf3yk

    3 ай бұрын

    I interested myself.

  • @johnnyhotrod

    @johnnyhotrod

    Ай бұрын

    @@robshandl3 Look on the front panel of your generator,it should say bonded or floating neutral.If it does not,refer to the manual. On a residential house the neutral can only be bonded once and that will be in your main breaker box. You don’t want a generator that is also bonded feeding your main panel. So if the neutral on your generator is bonded and you are going to feed your main panel,you would remove the bond.There are videos here on how to do it. It’s basically removing one wire from the ground or frame. Many never do it and don’t have a problem.

  • @maglen69
    @maglen695 ай бұрын

    Simple and to the point. Excellent video.

  • @paulinedavis8734
    @paulinedavis87344 ай бұрын

    Excellent...information & simple coherent delivery, as usual.

  • @DeltaCo7175
    @DeltaCo71755 ай бұрын

    Its great to see someone doing it the proper and safe way instead of some of the hackery done by some of the fools on youtube

  • @SilverCymbal

    @SilverCymbal

    5 ай бұрын

    I appreciate that. I am really dissapointed to see a few channels doing all these HVAC hookup hacks that are destructive for the heating system and totally illegal for the sake of views. I am all for quick fixes but some of these videos are teaching terrible ideas

  • @DeltaCo7175

    @DeltaCo7175

    5 ай бұрын

    not only terrible ideas but some could also cause injury or death @@SilverCymbal

  • @benzun9600
    @benzun96005 ай бұрын

    you are a smart dude thanks

  • @thatguy2608
    @thatguy26084 ай бұрын

    Excellent... Thanks 👍

  • @kennys3985
    @kennys39854 ай бұрын

    Can you explain a grid connect system such as if i wanted to connect solar. For example would there still be an interlock switch

  • @paulh6517
    @paulh65175 ай бұрын

    Thank you!

  • @DougKremer
    @DougKremer5 ай бұрын

    Installed one of these many years ago.

  • @arthendrickson4860
    @arthendrickson48605 ай бұрын

    I'm glad others addressed bonding. My question: Why wear those gloves? They appear to be simple latex gloves?

  • @SilverCymbal

    @SilverCymbal

    5 ай бұрын

    Yes, hopefully you saw my response. The structure was built in 1993, long before the 2008 bonding code changes and was designed for the current regs then. Gloves are for video clarity.

  • @Leonardokite
    @Leonardokite5 ай бұрын

    Far better than the EcoFlow transfer switch.

  • @mr1pearl
    @mr1pearl5 ай бұрын

    Hey Chris Mery Christmas 🎄

  • @SilverCymbal

    @SilverCymbal

    5 ай бұрын

    Thank you. you too!

  • @tracynation2820
    @tracynation28204 ай бұрын

    Super. In an emergency, if you only have a 120 volt generator, you can temporarily connect to both line 1 and line 2 as long as all 240 volt two pole breakers like the dryer, stove, and sub panel breakers are ALL turned off, as well as the main breaker. I have a short cnnversion cord that allows a 120 volt generator to connect to both poles of a 240 volt 30 ampere inlet from a standard extension cord, powering all 120 volt breakers, but you have to make sure to shut off, or not use, any 240 volt items. I have two inlets to my panel, along with the main/generator lockout, (More money = auto transfer switch) however, I have two inlet plugs, 120 volt × 20 ampere and 240 volt × 30 ampere connected to a 30 ampere transfer switch, so i can plug into most generators. I also have a large deep cycle 12 volt RV battery permanently hooked to a 1500 watt inverter, and a trickle charger, on a cart, which I can plug in to for quick emergencies. (20 ampere inlet.) The battery will run my hot water heating boiler, thermostat, pump, and valves for three days, which is longer than my generator runs on one tank of fuel. 💙 T.E.N.

  • @eosme
    @eosme3 ай бұрын

    what if my Main is located at the lower right hand side of the MPU? is there another interlock kit that would work?

  • @arunprasath4139
    @arunprasath41394 ай бұрын

    We use a 3phase changeover switch for mains and the generator.

  • @badjuju6563
    @badjuju65635 ай бұрын

    What changes are needed if you have a grid tied solar array on your home... any difference? With the grid tied systems they will not operate if AC is not present.... now we have AC from the generator. Will this damage your inverter or tour generator?

  • @diverm2371
    @diverm23714 ай бұрын

    Well done

  • @hardlashslentertainment5896
    @hardlashslentertainment589625 күн бұрын

    Nice video I’m trying to find the interlock kit but the link to the main feeding from the middle my main is on the opposite side of urs do I just move on the orther side and move break down like what u did

  • @brain_segfault
    @brain_segfault5 ай бұрын

    Great video. You should compare the eco flow battery to the new anchor households battery.

  • @SilverCymbal

    @SilverCymbal

    5 ай бұрын

    Thank you, yes I will have upcomign videos on the new Ecoflow and Anker as well. These systems have advanced so much in the past year

  • @BigBrotherIsTooBig
    @BigBrotherIsTooBig5 ай бұрын

    I just did this a few months back when a power line snapped from a pole and caught the pole on fire. We were without power for 1.5 days. I installed mine on the outside though.

  • @wubster100
    @wubster1004 ай бұрын

    Don't you need a breaker tiedown on the 30amp breaker like the 100amp has?

  • @michaeldidomenico6312
    @michaeldidomenico6312Ай бұрын

    Everyone is forgetting one item. By the electrical meter there should be a sign or label. Stating a secondary power source, for firemen or the power company. Check out article 702 i believe.

  • @Lettylemonade
    @Lettylemonade5 ай бұрын

    saving a lot of money

  • @NeilPBrooks
    @NeilPBrooks5 ай бұрын

    Yep, I agree. Overly complicated generator transfer switches are more expensive and don’t allow whole house connectivity.

  • @SilverCymbal

    @SilverCymbal

    5 ай бұрын

    Yes, I like the smart home panels but they are good for automatic stuff, but I am totally fine controlling what things I want on etc and as you said, its simple and cheap and very reliable.

  • @donh6416

    @donh6416

    5 ай бұрын

    The reason transfer switches are superior is that most generators can not supply a whole house. In this example you are supplying 30 amps thru the emergency breaker. You can easily overload this breaker, especially if the home is all electric. With a transfer switch, you select certain circuits to use during a utility outage. So, for safety, a transfer switch is the way to go

  • @michaellewis6569

    @michaellewis6569

    5 ай бұрын

    ​@@donh6416with this setup you can choose to turn on only the select circuits that you want to use. Maybe you want to use your stovetop to cook something so you turn off all the outlet circuits including fridge/freezer for an hour. Maybe you install a soft start kit on your air conditioner and choose to run that during the summer but in the winter you have the option of keeping something else on. Using a transfer switch just means you have to have made the decisions before hand and don't have any flexibility during an outage.

  • @mattlitton8066

    @mattlitton8066

    4 ай бұрын

    Transfer switches are good for folks who have no idea what they're looking at when opening a panel. I have a simple interlock setup, for the very reason you mention... i can run any circuit i want. but the Transfer switch is something I would choose for my mother in law, as she has no clue what is going on in her walls.@@michaellewis6569

  • @howtodoitdude1662

    @howtodoitdude1662

    4 ай бұрын

    I prefer a transfer switch because you are not using your main panel as the distribution. The transfer switch isolates itself from the main panel, bypassing it and feeding the individual breakers selected directly.

  • @judsimonson9087
    @judsimonson908711 күн бұрын

    Question about bonding neutrals. Since most inverter generators come with bonded neutrals and GFCI outlets, won't the transfer switch connect the bonded generator with the already bonded main panel and thus not be up to code?

  • @Kdawg101
    @Kdawg10118 күн бұрын

    Will adding generator power to one side of the panel only supply power to one side of panel only and not both?

  • @Kdawg101
    @Kdawg10117 күн бұрын

    Is this how you power both sides of the panel?

  • @silentvoiceinthedark5665
    @silentvoiceinthedark56654 ай бұрын

    The risk of and duration of power outage you have is directly proportional to the amount of money you spend on your back up system. If you wash your car it will rain, if you buy a snow blower it will not snow. BTW I have 2 manual GE knife throw switches $200 each. It is a simple one arm bandit style switch that lets you select between two sources of power.

  • @osiris055
    @osiris0555 ай бұрын

    Great video! I noticed grounds and commons going to the same bar and the bonding screw is installed. Is that a sub panel to your main panel? If so, you should consider removing the bond and separating your grounds and commons in the sub panel, otherwise it can lead to amperage on your ground.

  • @roscoe9988

    @roscoe9988

    2 күн бұрын

    I’m wiring an off grid cabin to be powered by a small Bluetti power station( 30 amp) and also gas generator (50 amp) as an alternative. Do I use a sub panel with a 50 amp breaker and a 30 amp breaker with interlock kit so I can keep the neutrals and grounds seperated ?

  • @itzNickyJayBeats
    @itzNickyJayBeats5 ай бұрын

    I am curious as to why you installed the plug on the inside as opposed to the outside of the house...?

  • @SilverCymbal

    @SilverCymbal

    5 ай бұрын

    I will be using this with battery 240v systems more than gas generators, they can't be outside, but I can always use a longer cord for gas models.

  • @RayLacks
    @RayLacks27 күн бұрын

    made it look easy!

  • @Let_em_know
    @Let_em_knowАй бұрын

    I'm kinda confused. So by moving the other circuit breakers down and putting the double pole generator breaker under the main, that makes it so the other breakers underneath will get power when flipped on?

  • @Zenkai76
    @Zenkai764 ай бұрын

    I wonder what I would have to do differently because I am backfeed through solar.

  • @LEONDELASIERRA1
    @LEONDELASIERRA19 күн бұрын

    All my plugs run on 120v except my dryer plug, canni still wire it loke this video or will it burn my appliances?

  • @JamesSmith-bj9vk
    @JamesSmith-bj9vk17 күн бұрын

    Can I convert that plug to receive a standard home appliance plug and just use a small 2K inverter?

  • @johnvillalovos
    @johnvillalovos5 ай бұрын

    That panel almost looks like a subpanel. If there is a disconnect upstream of that panel then the neutrals and grounds should be separated from each other and brought together at the main shutoff panel. If it is the main panel then it is good.

  • @SilverCymbal

    @SilverCymbal

    5 ай бұрын

    Yes, very good eagle eyes! This is a sub-panel but setup identically to a main panel. So it works great for what I did in the video and future stuff as I can stop messing with my main. But is it illegal or against code as we have all been taught despite not being the first point of disconnect. No. Why? Because it was built in 1993. The bonding changes to subpanels came in around 1999-2003. This structure is setup just as a main panel with it's own grounding system, etc.

  • @johnvillalovos

    @johnvillalovos

    5 ай бұрын

    @@SilverCymbal Thanks for the reply! And yes it remains legal if it was legal when first done 👍. Otherwise I would need to be installing GFCIs and AFCIs on almost everything in my house with the code changes 😂.

  • @TomCee53

    @TomCee53

    5 ай бұрын

    There are very real reasons why ground and neutral should be separated in sub panels and in the generator. Will it work, yes, but it’s much better to separate them. There are several good KZread videos on why this should be done. Your description seemed like you were separating them, but I could see both neutral and ground in each bus bar. It’s not hard to just remove the green bonding screw after moving each wire to the proper bar. As usual, it’s best to check with a pro if you’re not sure.

  • @TomCee53

    @TomCee53

    5 ай бұрын

    Actually,if you are adding an inlet, you may need to update. Each local authority sets their own rules, and can force you to get a permit and make changes . At the very least, it would have to pass inspection when you sell or rent the house.

  • @donm1547

    @donm1547

    5 ай бұрын

    SC, the power should have been isolated at the MAIN PANEL'S sub-feed breaker for this panel, the feeders coming from the bottom of this panel and the lugs at this main breaker were still HOT and exposed. Also, regardless of the 'grandfather clause' it would be in your best interest to isolate the neutrals in this sub-panel, there is a very specific reason the NEC added this requirement. Please do it. 😊

  • @utz716
    @utz7165 ай бұрын

    How about setting up an inlet inside and outside? I only have one outside and it's the best thing ever but inside would be great for me to use my ecoflow setup.

  • @SilverCymbal

    @SilverCymbal

    5 ай бұрын

    This one was installed inside my workshop. But I did exactly what you are asking for in my house, but to do it legally, you need to use a switchbox and it's very expensive despite the fact its just a simple switch. You can see that setup here: kzread.info/dash/bejne/q4J2uqdsctbgdbA.html

  • @utz716

    @utz716

    5 ай бұрын

    @@SilverCymbal Awesome thank you

  • @kennethsilvey6003
    @kennethsilvey60035 ай бұрын

    Well done. Where is the Predator 9500?

  • @Taylexwow
    @Taylexwow5 ай бұрын

    Cant speak for everywhere but the utility compaby I work for asks that you notify that a generator is wired to the panel. May not still apply that was before solar took off.

  • @TheMatthewDMerrill
    @TheMatthewDMerrill5 ай бұрын

    Solar generator is a term I've never thought I'd hear

  • @projectswithjw

    @projectswithjw

    4 ай бұрын

    The term shouldn't exist. Generators convert kinetic energy into electrical energy. Solar cells don't operator on kinetic energy so they are not generators.

  • @donm1547
    @donm15475 ай бұрын

    SC, the power should have been isolated at the MAIN PANEL'S sub-feed breaker for this panel, the feeders coming from the bottom of this panel and the lugs at this main breaker were still HOT and exposed. Also, regardless of the 'grandfather clause' it would be in your best interest to isolate the neutrals in this sub-panel, there is a very specific reason the NEC added this requirement. Please do it.

  • @SilverCymbal

    @SilverCymbal

    5 ай бұрын

    All good points. After further digging into the code and consulting with a few folks, the code for separating neutrals and grounds (in separate structures came out even after the 1999 main dwelling code)it came into effect in 2008 so it is fairly recent. The issue is this building was designed to be this way and is 200 feet from the house and has no ground back wire to the house (since having one would have been against the code at the time) but if I make changes I will address it at a future time.

  • @donm1547

    @donm1547

    5 ай бұрын

    @@SilverCymbal makes sense but keep in mind that the Utility transformer secondary's are grounded which is also where the single phase power derives the Main neutral from. If you lose your neutral(s), any ground path, including the soil and devices can become energized. Have a Merry Christmas SC.

  • @moobox
    @moobox5 ай бұрын

    I wish that these were legal in Canada. Instead we are forced to pay thousands for GenerLink or move half our circuits over to a sub-panel. This would be so easy.

  • @SilverCymbal

    @SilverCymbal

    5 ай бұрын

    Wow I didnt know that. Its funny I called generlink a few years back thinkng there solution was awesome, but they are crazy expensive as you said. It seemed lke just sell them through the power company for like $5/month and everyone would get them. But I guess they are greedy. Sad!

  • @moobox

    @moobox

    5 ай бұрын

    @@SilverCymbal in case you are curious I believe the reasoning for these interlocks not being legal is because they can be defeated by removing the cover on your electrical panel. So strange.

  • @brittblanton8342

    @brittblanton8342

    5 ай бұрын

    In February of 2022 I purchased the Generlink 30 -75KA with surge protection and that included a 20 foot 30 amp locking cord for 653 dollars and my utility company installed it for 20 dollars here in South Central Kentucky. I purchased it from North American Power Products dab Global Power Products 225 Arnold Road, Lawrenceville, Ga. 30044. I love it so safe and easy to use all they did on the install was pull the meter head off push the generator link in opening then push the meter head in the opening in the Generlink and you are ready it’s basically a automatic transfer switch and approved by most utility companies.

  • @ahtesamulhaque7507
    @ahtesamulhaque75075 ай бұрын

    My panel box is full. What can I do in this case? I’m pretty sure my previous electrician didn’t do a good job and I have a lot of unnecessary breakers. Is there something you recommend I can do to check if I can make more room/space to add the needed breakers for my generator?

  • @jamesborton9237

    @jamesborton9237

    4 ай бұрын

    Unnecessary breakers ? Can you consolidate enough circuits to free up a DP (Double Pole) breaker closest to the main breaker ? If you double up any , start with lighting circuits first. With LED lights now, the norm that should be possible. How old is your current electrical box, maybe it is time to upgrade to bigger amperage box with more slots. Another choice might be a transfer switch. Maybe consult your local career center or college and convince the instructor to use your house as a 'field trip' location for students. Promote net working by having refreshments for the class.

  • @MrJpiarull
    @MrJpiarull5 ай бұрын

    Do you also have a Generac or Kohler direct automatic start up or you only have a portable one? My parents have a Generac and it was a godsend during last couple early fall hurricanes and extreme snow blizzards

  • @SilverCymbal

    @SilverCymbal

    5 ай бұрын

    I don't have any automatic system, since they run on nat gas propane. We have a propane tank for heat but running on generator would be depleted it in about 3-4 days. Gasoline is more work but I can run for about 5-7 days & I have a chance to get more if a crisis happens where propane I am restricted due to my rural location that a delivery might not happen. My rural spot does add some complications.

  • @htran5vn
    @htran5vn11 күн бұрын

    My AC has 70amp breaker but my generator can only do 50amp. Can i still do this? Thank you.

  • @americannumber2
    @americannumber25 ай бұрын

    is this your sub-panel? looks like the green screw attached and the neutral bonded?

  • @SilverCymbal

    @SilverCymbal

    5 ай бұрын

    Yes, very good eagle eyes! This is a sub-panel but setup identically to a main panel. So it works great for what I did in the video and future stuff as I can stop messing with my main. But is it illegal or against code as we have all been taught despite not being the first point of disconnect. No. Why? Because it was built in 1993. The bonding changes to subpanels came in around 1999-2003. This structure is setup just as a main panel with it's own grounding system, etc.

  • @diverbob8
    @diverbob8Ай бұрын

    Great idea....except the code now has the main outside with the meter.

  • @dfloyd888
    @dfloyd8885 ай бұрын

    Would it help to install ferrules on the end of the wires?

  • @SilverCymbal

    @SilverCymbal

    5 ай бұрын

    Not for solid wire I would only use the solid conductors directly

  • @luke_fabis
    @luke_fabis5 ай бұрын

    Rather than a manual interlock, is there any kind of relay or automatic switch that can disconnect your house off and activate the generator in the event of a power outage?

  • @bikeny

    @bikeny

    5 ай бұрын

    I'm not an electrician or any sort of contractor person, but in the previous house I was living in, the landlord bought a whole-house generator and an automatic transfer switch. And as you might expect, there were 3 different people involved with the installation: electrician, propane person, and certified vendor representative. As a result, if the power went out, the sensors waited about 10 seconds before turning on the generator (propane-powered btw). No one had to go outside to power on anything. For the kind of generator he is using I am guessing (and it's a very uneducated one at that) that there is no automatic way to have it kick on, say, at 2am, when your power goes out. I would love it if there was an automatic way to have such automation with a gas generator. The automatic option is certainly a good way to go especially if you're in say a cold-weather environment and if the power goes out at that 2am time during a January snowstorm but you're sleeping. You wake up and the house is cold and with no automation now you've got to go out and turn things on. It's not a fun thing even if you discover the outage at 2am. This was my landlord's concern and during the last winter, they did kick on a couple of times. I'm sure the chickens i the house appreciated the power coming back on right away to power the heaters. Yeah, it wasn't just us people he was trying to keep toasty. He had about 20 chickens.

  • @karicallegra8194

    @karicallegra8194

    5 ай бұрын

    Kind of. It is usually two different things that do what you are asking. First to auto disconnect the your house from the grid they are called Automatic Transfer Switches (ATS). They sense when the grid power drops below a certain point, and then they switch over to the other input (assumidly your generator). Often they have built in sensors to ensure that the source that is being switched to is stable enough before making the switch. The other part is usually built into the generator itself. It monitors for a loss of power, in this case from the grid, and then once that is detected, starts the ignition sequence. For my home it takes approximately 10-20 seconds (less in the winter since no A/C drawing power) to be fully back up and running on my generator power. So anything critical (like my servers, computers, cameras, etc) I just have to make sure have enough UPS battry to last at least that long.

  • @axeami1354
    @axeami13544 ай бұрын

    I see a lot of backup generator video from the US, are power cuts a common thing across the us or do you guy just like to be prepared just in case ?

  • @SilverCymbal

    @SilverCymbal

    4 ай бұрын

    Depends where you live. In the NE US ther big problem is lack of power means no heat, so you can't go long without it.

  • @axeami1354

    @axeami1354

    4 ай бұрын

    @@SilverCymbal ahh I see, most people have gas heating here but I can see why people would want a back up just in case when you use electric.

  • @kidsalex13
    @kidsalex134 ай бұрын

    hi, just wondering if you or anyone has a suggestion if my panel is already full? It was that way when i bought the house

  • @mattlitton8066

    @mattlitton8066

    4 ай бұрын

    You would need to add a sub panel, or purchase and install a larger service panel.

  • @projectswithjw

    @projectswithjw

    4 ай бұрын

    Some panels can be fitted with tandem breakers. 2 circuits fit into a breaker that takes a single slot. Check your panel tag to see if its allowed.

  • @EdFilips
    @EdFilips3 ай бұрын

    I don’t believe this passes the NEC, as the neutral isn’t isolated to the home. This setup can send current to the street through the neutral. Neutral carries the unbalanced load.

  • @dolfinwriter5389
    @dolfinwriter53894 ай бұрын

    Are you just running your generator output cable through an open door? I don't have that option. I'm going to have to go through the wall of my house and into my basement utility area.

  • @SilverCymbal

    @SilverCymbal

    4 ай бұрын

    You can do that, I have done it through windows, obviously if its gas and their is exhaust you must make sure its far enough away. But I also use battery systems too and having it indoors is the only option for them, so you can do it whatever way suits your generator location best

  • @abecoulter8550
    @abecoulter85505 ай бұрын

    genrally with high current AC cable its not a good idea to leave a big pile of the cable coiled up, best to have about 8feet max more than what is needed, or it can act inductive under heavy loads,

  • @BillyBobDingledorf
    @BillyBobDingledorf5 ай бұрын

    Can you talk about what those of us with 120V generators would do? This solution appears to assume 240V. I believe most solar generators are also 120V.

  • @TomCee53

    @TomCee53

    5 ай бұрын

    Excellent point. You can only run one half of the panel on a 110v generator. He left out a lot of planning information.

  • @SilverCymbal

    @SilverCymbal

    5 ай бұрын

    Hang in there on this one. I will be showing you in an upcomign video how a 120v only generator can work with this same setup. There are some tradeoffs but you still gain a lot.

  • @jstins

    @jstins

    3 ай бұрын

    Looking forward to your 120v genny vid. @@SilverCymbal

  • @attribute-4677
    @attribute-46775 ай бұрын

    Unless you plan on running your generator inside, I’d recommend putting the outlet outside.

  • @TomCee53

    @TomCee53

    5 ай бұрын

    You should never run a generator inside, even in a garage. The carbon monoxide is nothing to mess with. There is really no difference between 25 feet of extension cord or 25 feet from panel to inlet. And yes it’s called an inlet.

  • @alfonso704

    @alfonso704

    5 ай бұрын

    You can always get a long generator extension cord. 30-50ft just keep out of the garage

  • @SilverCymbal

    @SilverCymbal

    5 ай бұрын

    Yes, except for me I plan to use this for battery systems 240v so I will end up using them in side. but yes absolutely if you only intend to use gasoline outside is just as easy.

  • @Flowing23
    @Flowing235 ай бұрын

    👍👍

  • @carlschiel4754
    @carlschiel47545 ай бұрын

    Do you need to screw down the generator breaker?

  • @snakeinthegrass7443

    @snakeinthegrass7443

    4 ай бұрын

    Yes he does

  • @tomnorman457

    @tomnorman457

    4 ай бұрын

    Curious why there’s a screw dead-center of the 100 amp main breaker? That can’t be a good thing.

  • @snakeinthegrass7443

    @snakeinthegrass7443

    4 ай бұрын

    @@tomnorman457 If it's a back-fed breaker - meaning the power comes into the breaker from the screw terminals and goes into the buss bar - (such as a main breaker or in this case, the generator breaker), then it has to be screwed down into place. If not, then if the breaker ever comes out, for whatever reason, you would be holding a breaker in your hand that is energized and that can make for a bad day.

  • @jstins

    @jstins

    3 ай бұрын

    @@snakeinthegrass7443 how do you screw it down? Can I use zip ties?

  • @snakeinthegrass7443

    @snakeinthegrass7443

    3 ай бұрын

    @@jstins If it's a fairly modern panel then there is already a threaded hole in the body of the panel for that screw. (Possibly only in the top few spaces so you may have to remove the top two breakers to find it). I don't think back-fed is the proper name for it but when you buy the breaker, make sure there is a hole in it for the screw that's specifically designed for this application. It may possibly be called a hold-down screw. (DON'T USE A DRYWALL SCREW, PEOPLE) I don't think you'll find these at Depot or Lowes so just go to an electrical supplier in your area and tell them what your doing. All you should need for them is the panel type and model, if applicable. Take a pic of any label you can find if you're still unsure. And if you use a zip tie, you won't be able to get the cover back on properly. Side note here. I do recall using a different type of "bracket" to hold down the breaker before. It was a piece of metal bent to go over the breaker and attach somehow to the box. But I haven't seen that in a long time and I can't remember the details of it. It was most likely in an older panel. So if your panel is ancient, there still may be hope. The electrical counter folks should be able to tell you if what you have can accommodate what you're trying to do. If not, than it's probably time to modernize your service. Hope that helps.

  • @asterixky
    @asterixky5 ай бұрын

    Breakers have to be brand specific and matching the panel.

  • @SilverCymbal

    @SilverCymbal

    5 ай бұрын

    Yes. that is a very good point. I made a more detailed breaker replacement video that might be helpful: kzread.info/dash/bejne/ppVkpdiug6q3l7w.html

  • @njgrplr2007
    @njgrplr20073 ай бұрын

    Why not go with a 50 amp inlet and use an adapter to connect your 30 amp line? That way you won't have to change anything if you upgrade your generator.

  • @kenfused
    @kenfused5 ай бұрын

    How come your Rachio is still lit up ? I thought power was off

  • @SilverCymbal

    @SilverCymbal

    5 ай бұрын

    Its plugged into an outlet splitter along with my light (for the video) and of course those were plugged into a little Ecoflow: amzn.to/41xZGwJ

  • @CheaddakerT.Snodgrass
    @CheaddakerT.Snodgrass5 ай бұрын

    What is the purpose of the screw between the two main breakers?

  • @SilverCymbal

    @SilverCymbal

    5 ай бұрын

    Some manufacturers do this on convertible panels, where you may not need a main breaker. It's just a physical holddown so the breaker is never accidentally pulled out. It looks like a homeowner just shovewd a wood screw in there but it is from Eaton or Cutler Hammer as they were known when this panel was made.

  • @CheaddakerT.Snodgrass

    @CheaddakerT.Snodgrass

    5 ай бұрын

    @@SilverCymbalThank you, I suspected it was something like that. I think the only thing setup is missing is a visual indicator of the power coming back on. Obviously that would be a much more complex connection; if you happen to create it I'll take 20% of profits as a finders fee.

  • @ig_foobar

    @ig_foobar

    5 ай бұрын

    @@SilverCymbal @CheaddakerT.Snodgrass A hold down is also needed on the generator breaker. If your panel will accept another breaker with the screw in the middle, that's probably the best way to go. Sometimes there is a hold down kit available from the panel manufacturer. 408.36 Overcurrent Protection. (D) Back-Fed Devices. Plug-in-type overcurrent protection devices or plug-in type main lug assemblies that are backfed and used to terminate field-installed ungrounded supply conductors shall be secured in place by an additional fastener that requires other than a pull to release the device from the mounting means on the panel.

  • @neilbrookins8428

    @neilbrookins8428

    5 ай бұрын

    @@CheaddakerT.SnodgrassI have the reliance controls power back alarm. It gives me a signal when the power from the utility returns. It’s from the same company as the inlet box he shows.

  • @CheaddakerT.Snodgrass

    @CheaddakerT.Snodgrass

    5 ай бұрын

    ​​@@neilbrookins8428Drats! My millions have been foiled! Thanks for letting me know though. But does it work when the generator is running and hooked into the house panel?

  • @95dodgev10
    @95dodgev105 ай бұрын

    I wish my breakers were only $12. My panels are out dated and only one company still makes breakers for them. They've ran me anywhere between $50 and $100 for double pole breakers.

  • @snakeinthegrass7443

    @snakeinthegrass7443

    4 ай бұрын

    It's not a Federal Pacific, is it?

  • @95dodgev10

    @95dodgev10

    4 ай бұрын

    @@snakeinthegrass7443 no the name starts with a W but it's not Westinghouse. Can't remember the name and i don't feel like walking down there at the moment lol

  • @snakeinthegrass7443

    @snakeinthegrass7443

    4 ай бұрын

    @@95dodgev10 You got me stumped, then.

  • @frankazevedo7983
    @frankazevedo7983Ай бұрын

    Canadian here, not legal in Ontario, Canada

  • @222branflakes
    @222branflakes5 ай бұрын

    If you're going to advise people to use this as a guide, you should probably start using some test equipment to confirm circuits are dead.

  • @SilverCymbal

    @SilverCymbal

    5 ай бұрын

    Certainly good advice for sure

  • @MatthewMoss644

    @MatthewMoss644

    4 ай бұрын

    Sending a long screw through the plywood to poke the wires is not good. @3:22

  • @Ironmuffins308

    @Ironmuffins308

    4 ай бұрын

    This should not be used as a guide, you would want a transfer switch on the incoming power. If you need a guide like this then you wont understand how to sync synchronous ac power and should not be back feeding your power. It’s very easy to not open your incoming power and cause a short resulting in a fire if you don’t understand what you are doing.

  • @TheMopar97

    @TheMopar97

    4 ай бұрын

    @@Ironmuffins308 please explain how this set up is not valid. Literally thousands of videos if professionally installed set ups just like this one.

  • @conqueringlion420

    @conqueringlion420

    3 ай бұрын

    Those people are already dead

  • @paulinedavis8734
    @paulinedavis87344 ай бұрын

    Curious to know if you considered Gener link... before the installation of a transfer switch ? Not many people are skilled or comfortable with electricity especially 240Volts

  • @SilverCymbal

    @SilverCymbal

    4 ай бұрын

    I would love to get one of them, but something is weird about their company. They seem to always be out of stock and don't reply to customer inquiries that I have seen and I honestly thought they were out of business. An electrician told me once the problem with them is that most customers don't have their meter where they want their generator. But I did like the concept. popwer companies shoudl rent them for like $5/mo they would make a fortune

  • @paulinedavis8734

    @paulinedavis8734

    4 ай бұрын

    @@SilverCymbal Where I am located in New Brunswick, Canada, the New Brunswick Power Company will install one free on your meter for a fee of $23 a month. I just went through a 6 day power outage Dec18-23, 2023 after a rain & 100km hour winds storm. I am considering getting Generlink and a larger 8000-10000 watt generator.

  • @SilverCymbal

    @SilverCymbal

    4 ай бұрын

    @@paulinedavis8734 I would absolutely do that, especially with their support. If the meter is a good spot for the generator hookup I can't see any downside. Must be that they are not well established maybe in the US. Lucky that you can get one!

  • @paulinedavis8734

    @paulinedavis8734

    4 ай бұрын

    @@SilverCymbal House & Garage are separate & detached ....I hope a I will be able to run a long 50 amp cord from the meter on one side of my house to a generator near my garage on the opposite side ????

  • @fritzrobinson6064
    @fritzrobinson60644 ай бұрын

    Please note that certain countries do not allow you to install interlocks.

  • @stuffoflardohfortheloveof
    @stuffoflardohfortheloveof5 ай бұрын

    Anyone care to explain what 'backfeeding' actually is? And why it's dangerous? 👍

  • @SilverCymbal

    @SilverCymbal

    5 ай бұрын

    Right here: kzread.info/dash/bejne/a5-e0rVqpsmtmdI.html

  • @jameskoehler4939
    @jameskoehler49393 ай бұрын

    I'm an electrical contractor and I install many of these set-ups. I will NEVER install the inlet inside of a building or garage. I will only install those on outside walls. You might be smart enough to never run the generator inside the garage, but you may sell the house to some idiot who decides to buy the shortest cord for their generator, then runs the generator in the garage, and ends up killing their family. Carbon monoxide poisoning kills more people that you would believe, and I will do my best to prevent that from happening.

  • @echohotel1094

    @echohotel1094

    3 ай бұрын

    Carbon monoxide is CO, not CO2. Just saying...

  • @jameskoehler4939

    @jameskoehler4939

    3 ай бұрын

    @@echohotel1094 You are correct sir. I edited. Not sure how that brainworm got in.

  • @SaketIyer
    @SaketIyer5 ай бұрын

    I dont know why auto changeovers aren't so talked about in US. It's cheap and automatic

  • @SilverCymbal

    @SilverCymbal

    5 ай бұрын

    They do exist for RV's and for houses but our problem is that we can't switch our mains off which means auto switches need to wired into our main leads which makes a retrofit installation much more complicated and in some cases our electric codes won't allow it. I really don't mind it being manual since when we lose power its storm related and I don't want to use up fuel or battery life automatically since my run time will be limited so if I came home from work and the power was out my AC could have depleted the batteries or gas completely.

  • @SaketIyer

    @SaketIyer

    5 ай бұрын

    @@SilverCymbal That makes sense. Coming from a place where powercuts are common, we have separate circuits for all the low power appliances and are run on UPS and the higher powers on raw power. The UPS kicks in automatically, and the auto transfer switches kick in when the diesel generators start and take it to DG power, charging the UPS and running the house. Basically three different power sources. The transfer switches are smart enough to switch back to mains power even if it is getting two power sources at a time.

  • @avvarutheja
    @avvarutheja5 ай бұрын

    I have done the same, but instead of generator, I am using my electric vehicle as source. This way during power outage, my EV provides power to home.

  • @bmir89
    @bmir893 ай бұрын

    Beware Canadians, Interlock kits are illegal in Canada.

  • @TomGreene
    @TomGreene5 ай бұрын

    Come on. You did a video on Wago and you use a Menards connect in your panel. Pick a lane.

  • @SilverCymbal

    @SilverCymbal

    5 ай бұрын

    Those aren't from me. In fact if you watch close at the start of the video there were two double tapped (with wire nuts) on the left side, I yanked them out and installed 2 new breakers to clean things up a bit. The remaining 3 wirenuts on the left will be changed to Wagos at some point.

  • @wankerswaterwerks8108
    @wankerswaterwerks81083 ай бұрын

    30 amps won't power your whole house. Most AC condensers require 25-40 amps alone.

  • @steverefer
    @steverefer3 ай бұрын

    Don't have a generator any more but ,on the cheap, I thought if during a power outage, I could pull the main breaker then connect the generator to an exterior outlet I would have whole house power. ..Opinions??...

Келесі