This is the best felicity battery capacity test I have ever seen. Please keep on the good work.
@Tranquilitarian Жыл бұрын
When you consider that a 3.2V lifepo4 cell is considered fully charged at 3.6V and empty at 2.5V the shutoff voltage of 48.1V is protecting the cells and discharging to 44,8V or 44V might give you the full 5Kwh.
@prosperityokechukwu15037 ай бұрын
Wow thank u so so much. This is indeed the best battery capacity test ive seen on felecity
@Engineerizo10 ай бұрын
Thank you so much for this test is what I've been wanting you gave me the reality I was looking for thank you plz 😊🙏🙏
@DicksonAntoineKoalick-ke2jl Жыл бұрын
Thank you for the explanation i appreciated it helps me a lote
@MarkSmith-Uzor Жыл бұрын
Wow I am very pleased and so impressed that you could go all the way to show this very rear and highly anticipated research for we Nigerians to see!! Thanks alot and I am so subscribed for more updates on felicity lithium batteries!!
@diyfalke
Жыл бұрын
Thank you, I'm glad you like it.
@peterakoh3432
Жыл бұрын
What's the model of this inverter, is it IVPS5048 or IVPM5048?
@diyfalke
Жыл бұрын
@@peterakoh3432 IVPL5048
@peterakoh3432
Жыл бұрын
@@diyfalke okay, can you please do a video on IVPS3524 or/and IVPM3548?
@JamesT655 ай бұрын
Thank you my friend I am looking at this type of battery here in the philippines.
@DrEnockNorthVoltageEngineering Жыл бұрын
86%...The DOD mostly is around 80%...I had a chat with Felicity Engineers. So 86% of capacity is good for use. When one designs a system, a service factor of 1.25 is recommended. 25% of capacity should be left to increase the life of batteries (LiFePO4).
@ESEROGHENE2 ай бұрын
Great job
@tundeolaniran62597 ай бұрын
Well done💯👍 engineer
@davidniquot6423 Жыл бұрын
CATL FFH3D3 inside = 86Ah, 16x = 4.4kWh not 5kWh.
@godswilleni881510 ай бұрын
Try to Charge the battery to its full capacity and drain it fully again so that you can unlock the capacity more as it may have been sitting idle for too long and needs a few circles to unlock its maximum capacity.
@ekwevugbebonus7642 Жыл бұрын
Nic job bro
@diyfalke
Жыл бұрын
Thank you so much 😀
@bimmers323ci Жыл бұрын
Way 2 go
@Leo-cl1xq Жыл бұрын
What felicity solar tell you about this they will refund part of the money ?
@vroor32 Жыл бұрын
My friend.... I have a 24v240Ah lifepo4 battery and im using the same battery monitor. Its not showing the SOC meter for some reason. Its driving me crazy. I've watched all connection instruction videos and everything it correct. The soc meter was working with my 12v lead acid battery 😡
@victorsolomon4277 Жыл бұрын
Hello sir please is EG4 available in Nigeria? if yes where can l get EG4 in nigeria.
@xtremeideaz4 ай бұрын
Hello, where can i get this battery monitor? please does it have bluetooth or wifi for remote monitoring ?
@agirifrancisabraham1211 Жыл бұрын
Hello! I am a Solar Energy Engineer and Installer, living in Abuja. How do work with you?
@VinayJhinkoe Жыл бұрын
I believe in a previous video one of the qr stickers says 276wh right, so thats 86ah. The total capacity would bd 4.41kwh, so it is close enough. Felicity is not honest with their claims. My 300ah tower battery can only do 271ah instead of 300
@diyfalke
Жыл бұрын
Yes, they are not honest with their claim of 5kwh, but for the price I think it's still a good deal.
@davidniquot6423
Жыл бұрын
@@diyfalke Do not know how much you payed for it, i bought 16x CATL FFH3D3 (same cells that are in your Felicity) and paeyd 590€. Add over this a BMS (100€ = 2A active balancing) => 690€.
@muky05 Жыл бұрын
This is a very good job Hamidu. Many thanks for your efforts to let us understand how these batteries are. Can I have your number for consultancy purposes? I will appreciate it. Na Gode.
@diyfalke
Жыл бұрын
I'm glad you like it, Check out my WhatsApp link in the about tab of my channel. Na gode.
@potsandmiguelplayground9799 Жыл бұрын
Im using the 5kw felicity powerwall batt with 2pcs x 1hp inverter acs. 1double doors dual inverter ref and lights and it could last 5 to 5 n half hours. Is it good enough or should it be doing better?
@diyfalke
Жыл бұрын
I'm not sure about the ambient temperature in your location, as it relates to you AirCon power consumption, but I think 5hours is really good. In my location, it runs 1.5hp Aircon, TV and some lights for about 4hrs give or take.
@potsandmiguelplayground9799 Жыл бұрын
Please what is your bulk voltage, float voltage and low voltage cut off voltage? Thanks. Good video
@diyfalke
Жыл бұрын
Hi, I set my bulk and float voltages to 56.4v, Low cut off voltage to 48.8v.
@potsandmiguelplayground9799
Жыл бұрын
@@diyfalke Nice. Thank you sir for the video
@kujirasami376 Жыл бұрын
I always say it. Felicity Solar are not honest with their battery rating. This is broad day rubbery and they need to be honest. 4.4K rated for 5k is bad.
@paaata1494
Жыл бұрын
What's wrong with you
@Jorgerowland Жыл бұрын
Please can you use 1hp Air-condition as the load? I want to see how long it can take it
@diyfalke
Жыл бұрын
Let's say 1hp consumes average of 920w each hour, the actual capacity of the battery is 4400Wh, at 80% DOD, the usable capacity is 3520Wh, this means, when fully charged this battery can safely run 1hp Air-condition for 4 hours. The battery can deliver 2200W continuously (@0.5c) and a surge of 4400W (@1C) for few seconds.
@victoradeogo8244 Жыл бұрын
Please how do you calculate load with respect to the required battery capacity
@diyfalke
Жыл бұрын
Check out this video by Will Prowse on sizing your solar system kzread.info/dash/bejne/hn52qcSulsjedbA.html
@officialnewgistpc9605 Жыл бұрын
Our inverter is displaying fault and its not charging as well he power doesn't last at all
@LifeOfScope10 ай бұрын
I would actually prefer to buy the LifePo4 cell myself and build a better power bank
@fredrickolowojesiku64199 ай бұрын
was your watt meter configure well. i mean the shunt current capacity set to the rated value?
@diyfalke
8 ай бұрын
Sure, why?
@knowledge_seeker80 Жыл бұрын
anybody has felicity battery & deye inverter I am planing to make independent mobile app to monitor felicity battery over internet
@famousosado7661 Жыл бұрын
Please, How many of 200AH dry cell battery is this 5KWA 48V felicity lithium battery equivalent to?
@diyfalke
Жыл бұрын
You are recommended to discharge dry cell battery to 50% DOD to get the most cycles out of it, so A 5KWH lithium battery discharge to 80% DOD is equivalent to 3.3NR of 200ah Lead Acid battery discharge to 50% DOD.
@laurabarnes3295
Жыл бұрын
800ah because you are taking 50% of dry cell which 400ah is 4kw so to get 4kw you get 800ah dry cell and get 4kw from it ,4kw in the sense that the 5kw is to be taking out 4kw from it
@marketingtherapyoffcial Жыл бұрын
Do you have teardown video for LPBA 48170 ? they say it is A+ cells but in fact it is not
@diyfalke
Жыл бұрын
I have not, I'm hoping to get my hand on one soon. How can one tell grade A cells from B? The only information I heard is A+ cells passes all the test required to be used in EV.
@marketingtherapyoffcial
Жыл бұрын
@@diyfalke I opened one yesterday and I found a barcode with B letter , send your email I send you the picture
@marketingtherapyoffcial
Жыл бұрын
@@diyfalke the LPBA84170 is the biggest lie in 2022 . it is not A+
@diyfalke
Жыл бұрын
@@marketingtherapyoffcial diyfalke@gmail.com
@odeywilliams7596 Жыл бұрын
Do a tear down and show use the kind of cells felicity is using
@diyfalke
Жыл бұрын
kzread.info/dash/bejne/kWtn0tySiqfTqNo.html
@odeywilliams7596
Жыл бұрын
@@diyfalke thank you ive seen the video
@odeywilliams7596
Жыл бұрын
I think buying battery from Alibaba is cheaper than buying in Nigeria here
@diyfalke
Жыл бұрын
@@odeywilliams7596 not necessarily, this $700 on Alibaba without shipping, it will defend on how much dollar exchange and how you get it.
@odeywilliams7596
Жыл бұрын
@@diyfalke ok
@kukupulus2949 Жыл бұрын
4.3/5.0 x 100%= 86%. Not bad but could have been better. Any reason for not being able to set the highest charging voltage(floating/absorption) to the recommended 57.6v or even to 55.2v? Probably, you could have gotten a higher capacity than the 4.3Ah if you started draining from the higher floating voltage. Well done Sir for the review..
@diyfalke
Жыл бұрын
I attempted to charge the pack to 57.6v, but as the voltage hit 57 sometimes jump to even 60v, the charge controller will cut off with an error 04, which means battery voltage too high. Then it will reconnect and attempt to charge to 57.6v again. The only two logical explanation i have are either the MPPT is not good or 57.6v is too high for the packe.
@diyfalke
Жыл бұрын
I tried 2 other MPPT (both Felicity) reduce the charging voltage to 56.8, 56.4v, 56v, 55.6v, and even 55.2v, the same thing happened. Until I assume the pack is 15s, and take the Max for cell to 3.65v which gives 54.75v, the battery charge in a typical way, and the soc bar indicates fully charge. So until I open the inside, I think the battery is 15s, and you can only charge 16s to 57.6v i.e 3.6v per cell.
@davidniquot6423
Жыл бұрын
@@diyfalke One cell is rising faster then the others, triggering the BMS single cell overvoltage.
@DrEnockNorthVoltageEngineering
Жыл бұрын
@@diyfalke Being too long at the peak voltage or lower voltage is something the BMS will not allow. Also, it could be the software aspect. We did one installation last year we had error 04 for the 5 kW Inverter (IVEM) and the 170 Ah / 48V at panel voltages higher than 270 V (for 450 V maximum). We reported and were sent a software upgrade for the Inverters. Once we upgraded the software, the error was no longer there. I see it as a good move for the BMS regulation as you can still build charge at the other voltages.
@mexossai7982 Жыл бұрын
Using a must 5kva inverter, it has inbuilt mppt. Using a generator to charge my felicity 7.2kwh lithium battery. Is there a device I can use to make the gen charge the battery easier. I use a 5kva generator. Thanks in advance
@diyfalke
Жыл бұрын
I assumed the inverter doesn't have inbuilt AC charger, or the AC charger current of the inverter is small. you can consider buying a 48v AC charger, check out these video by Will Prowse. kzread.info/dash/bejne/l4Wt2rVxZtuymMo.html
@mexossai7982
Жыл бұрын
@@diyfalke thank you so much
@mexossai7982
Жыл бұрын
@DIY Solar Power with Falke Amazing. Thank you very much. Pls quick question, how would I connect it so I do not need to unplug my current inverter to the battery. Thanks once again
@diyfalke
Жыл бұрын
@@mexossai7982 I'm afraid you must disconnect the inverter, the chargeverter comes with Seamless Crimp (SC) Lug. What worries you about disconnecting the inverter? You can chat me up, my WhatsApp is on the about tab.
@caniceonuoha Жыл бұрын
What is the reliability of Felicity batteries and the grade of the batteries cells?
@diyfalke
Жыл бұрын
I have had this for only 10 weeks, so far there no single issue, the main issue many had with Felicity batteries is the overrated capacity. They have another series made for European customers, these could definitely have greater build quality, more accurate capacity rating and probably better BMS due to the low temperature in the winter.
@caniceonuoha
Жыл бұрын
@@diyfalke given your experience, would you advise someone to go with Felicity for a 75KVA buildout or look elsewhere for other batteries
@diyfalke
Жыл бұрын
@@caniceonuoha I take it you mean 75KWH battery bank. If so, I will say it depends on the budget and location of use. Compared to other brands like Pylontech, EG4, and BattleBorn etc, Felicity cost a fraction of these brands, the Felicity LPBF series have greater value for money, I will hardly recommend the LPBR series to anyone. The LPBA series are in the same league with EG4 in the price range, amongst the two, I will always go for EG4. Even the Felicity LPBF series have two or more class, one promising >=3000 cycle, the other 6000 Cycle.
@caniceonuoha
Жыл бұрын
@@diyfalke thank you. I didn’t know that EG4 is available in Nigeria.
@caniceonuoha
Жыл бұрын
@@diyfalke hi I sent you mail
@officialnewgistpc9605 Жыл бұрын
I need a contact to one of your professionals
@diyfalke
Жыл бұрын
I'm sorry you are having difficulty with your setup, however I do not work with Felicity solar, nor in anyway affiliated to them. But i will be more than happy to help you in any way I can.
@laurabarnes3295 Жыл бұрын
My inverter stop reading pv and dosent supply current but wen I put on my Account charge the inverter will supply current
@diyfalke
Жыл бұрын
sorry, your question is not clear.
@laurabarnes3295
Жыл бұрын
Inverter goes off when you put it on. It goes of after a minute even wen de is no load ,and if you put panel it dose not show either
@Jorgerowland Жыл бұрын
How long can this battery serve ?
@diyfalke
Жыл бұрын
It can serve you upto 3000 cycles @80% DOD before the capacity decays to 80%
@davidniquot6423
Жыл бұрын
@@diyfalke They are given for 2000 cycles and aging give 80% capacity after 11 years. (CATL FFH3D3)
@diyfalke
Жыл бұрын
@@davidniquot6423 I believe if a manufacturer can lie about the capacity, they can be lying about other things, and I only see the datasheet of CATL FFH3DS, which has >=3500 cycle life.
@chuksobi593
Жыл бұрын
@@diyfalke trust me if they use catl cells in those, it will cost way more
@victorsolomon4277 Жыл бұрын
Hello bros, how many hours backup time will Felicity 5KWH/24V LITHIUM BATTERY power 550watt load.
@diyfalke
Жыл бұрын
To calculate backup time for 5KWH battery, you first decide the depth of discharge (or usable capacity) say Felicity recommend 80% DOD, which means the usable capacity is 5000Wh * 0.8 = 4000Wh. This means you can run a load of 4000w for an hour. 2. If the load of 550w is including the inverter no load consumption fine, else add the no load power consumption to the load. This can be found in the inverter manual, or you can measure it with clamp meter. 3. Divide the total load(including no load consumption) by the efficiency of the inverter. Assuming 90% efficiency, that is 550w/0.9 = 611w. 4. Divide the usable capacity of the battery by the the load result calcilated in 3 above. That is 4000Wh/611w = 6.55h or 6h 33minutes. Summary. The Felicity 5KWH battery can safely run a load of 550w for 6h33min.
@imaditani29888 ай бұрын
Felicity is a waste of money. Used old cells inside. No guarantee no maintenance even at Felicity service center
Пікірлер: 95
This is the best felicity battery capacity test I have ever seen. Please keep on the good work.
When you consider that a 3.2V lifepo4 cell is considered fully charged at 3.6V and empty at 2.5V the shutoff voltage of 48.1V is protecting the cells and discharging to 44,8V or 44V might give you the full 5Kwh.
Wow thank u so so much. This is indeed the best battery capacity test ive seen on felecity
Thank you so much for this test is what I've been wanting you gave me the reality I was looking for thank you plz 😊🙏🙏
Thank you for the explanation i appreciated it helps me a lote
Wow I am very pleased and so impressed that you could go all the way to show this very rear and highly anticipated research for we Nigerians to see!! Thanks alot and I am so subscribed for more updates on felicity lithium batteries!!
@diyfalke
Жыл бұрын
Thank you, I'm glad you like it.
@peterakoh3432
Жыл бұрын
What's the model of this inverter, is it IVPS5048 or IVPM5048?
@diyfalke
Жыл бұрын
@@peterakoh3432 IVPL5048
@peterakoh3432
Жыл бұрын
@@diyfalke okay, can you please do a video on IVPS3524 or/and IVPM3548?
Thank you my friend I am looking at this type of battery here in the philippines.
86%...The DOD mostly is around 80%...I had a chat with Felicity Engineers. So 86% of capacity is good for use. When one designs a system, a service factor of 1.25 is recommended. 25% of capacity should be left to increase the life of batteries (LiFePO4).
Great job
Well done💯👍 engineer
CATL FFH3D3 inside = 86Ah, 16x = 4.4kWh not 5kWh.
Try to Charge the battery to its full capacity and drain it fully again so that you can unlock the capacity more as it may have been sitting idle for too long and needs a few circles to unlock its maximum capacity.
Nic job bro
@diyfalke
Жыл бұрын
Thank you so much 😀
Way 2 go
What felicity solar tell you about this they will refund part of the money ?
My friend.... I have a 24v240Ah lifepo4 battery and im using the same battery monitor. Its not showing the SOC meter for some reason. Its driving me crazy. I've watched all connection instruction videos and everything it correct. The soc meter was working with my 12v lead acid battery 😡
Hello sir please is EG4 available in Nigeria? if yes where can l get EG4 in nigeria.
Hello, where can i get this battery monitor? please does it have bluetooth or wifi for remote monitoring ?
Hello! I am a Solar Energy Engineer and Installer, living in Abuja. How do work with you?
I believe in a previous video one of the qr stickers says 276wh right, so thats 86ah. The total capacity would bd 4.41kwh, so it is close enough. Felicity is not honest with their claims. My 300ah tower battery can only do 271ah instead of 300
@diyfalke
Жыл бұрын
Yes, they are not honest with their claim of 5kwh, but for the price I think it's still a good deal.
@davidniquot6423
Жыл бұрын
@@diyfalke Do not know how much you payed for it, i bought 16x CATL FFH3D3 (same cells that are in your Felicity) and paeyd 590€. Add over this a BMS (100€ = 2A active balancing) => 690€.
This is a very good job Hamidu. Many thanks for your efforts to let us understand how these batteries are. Can I have your number for consultancy purposes? I will appreciate it. Na Gode.
@diyfalke
Жыл бұрын
I'm glad you like it, Check out my WhatsApp link in the about tab of my channel. Na gode.
Im using the 5kw felicity powerwall batt with 2pcs x 1hp inverter acs. 1double doors dual inverter ref and lights and it could last 5 to 5 n half hours. Is it good enough or should it be doing better?
@diyfalke
Жыл бұрын
I'm not sure about the ambient temperature in your location, as it relates to you AirCon power consumption, but I think 5hours is really good. In my location, it runs 1.5hp Aircon, TV and some lights for about 4hrs give or take.
Please what is your bulk voltage, float voltage and low voltage cut off voltage? Thanks. Good video
@diyfalke
Жыл бұрын
Hi, I set my bulk and float voltages to 56.4v, Low cut off voltage to 48.8v.
@potsandmiguelplayground9799
Жыл бұрын
@@diyfalke Nice. Thank you sir for the video
I always say it. Felicity Solar are not honest with their battery rating. This is broad day rubbery and they need to be honest. 4.4K rated for 5k is bad.
@paaata1494
Жыл бұрын
What's wrong with you
Please can you use 1hp Air-condition as the load? I want to see how long it can take it
@diyfalke
Жыл бұрын
Let's say 1hp consumes average of 920w each hour, the actual capacity of the battery is 4400Wh, at 80% DOD, the usable capacity is 3520Wh, this means, when fully charged this battery can safely run 1hp Air-condition for 4 hours. The battery can deliver 2200W continuously (@0.5c) and a surge of 4400W (@1C) for few seconds.
Please how do you calculate load with respect to the required battery capacity
@diyfalke
Жыл бұрын
Check out this video by Will Prowse on sizing your solar system kzread.info/dash/bejne/hn52qcSulsjedbA.html
Our inverter is displaying fault and its not charging as well he power doesn't last at all
I would actually prefer to buy the LifePo4 cell myself and build a better power bank
was your watt meter configure well. i mean the shunt current capacity set to the rated value?
@diyfalke
8 ай бұрын
Sure, why?
anybody has felicity battery & deye inverter I am planing to make independent mobile app to monitor felicity battery over internet
Please, How many of 200AH dry cell battery is this 5KWA 48V felicity lithium battery equivalent to?
@diyfalke
Жыл бұрын
You are recommended to discharge dry cell battery to 50% DOD to get the most cycles out of it, so A 5KWH lithium battery discharge to 80% DOD is equivalent to 3.3NR of 200ah Lead Acid battery discharge to 50% DOD.
@laurabarnes3295
Жыл бұрын
800ah because you are taking 50% of dry cell which 400ah is 4kw so to get 4kw you get 800ah dry cell and get 4kw from it ,4kw in the sense that the 5kw is to be taking out 4kw from it
Do you have teardown video for LPBA 48170 ? they say it is A+ cells but in fact it is not
@diyfalke
Жыл бұрын
I have not, I'm hoping to get my hand on one soon. How can one tell grade A cells from B? The only information I heard is A+ cells passes all the test required to be used in EV.
@marketingtherapyoffcial
Жыл бұрын
@@diyfalke I opened one yesterday and I found a barcode with B letter , send your email I send you the picture
@marketingtherapyoffcial
Жыл бұрын
@@diyfalke the LPBA84170 is the biggest lie in 2022 . it is not A+
@diyfalke
Жыл бұрын
@@marketingtherapyoffcial diyfalke@gmail.com
Do a tear down and show use the kind of cells felicity is using
@diyfalke
Жыл бұрын
kzread.info/dash/bejne/kWtn0tySiqfTqNo.html
@odeywilliams7596
Жыл бұрын
@@diyfalke thank you ive seen the video
@odeywilliams7596
Жыл бұрын
I think buying battery from Alibaba is cheaper than buying in Nigeria here
@diyfalke
Жыл бұрын
@@odeywilliams7596 not necessarily, this $700 on Alibaba without shipping, it will defend on how much dollar exchange and how you get it.
@odeywilliams7596
Жыл бұрын
@@diyfalke ok
4.3/5.0 x 100%= 86%. Not bad but could have been better. Any reason for not being able to set the highest charging voltage(floating/absorption) to the recommended 57.6v or even to 55.2v? Probably, you could have gotten a higher capacity than the 4.3Ah if you started draining from the higher floating voltage. Well done Sir for the review..
@diyfalke
Жыл бұрын
I attempted to charge the pack to 57.6v, but as the voltage hit 57 sometimes jump to even 60v, the charge controller will cut off with an error 04, which means battery voltage too high. Then it will reconnect and attempt to charge to 57.6v again. The only two logical explanation i have are either the MPPT is not good or 57.6v is too high for the packe.
@diyfalke
Жыл бұрын
I tried 2 other MPPT (both Felicity) reduce the charging voltage to 56.8, 56.4v, 56v, 55.6v, and even 55.2v, the same thing happened. Until I assume the pack is 15s, and take the Max for cell to 3.65v which gives 54.75v, the battery charge in a typical way, and the soc bar indicates fully charge. So until I open the inside, I think the battery is 15s, and you can only charge 16s to 57.6v i.e 3.6v per cell.
@davidniquot6423
Жыл бұрын
@@diyfalke One cell is rising faster then the others, triggering the BMS single cell overvoltage.
@DrEnockNorthVoltageEngineering
Жыл бұрын
@@diyfalke Being too long at the peak voltage or lower voltage is something the BMS will not allow. Also, it could be the software aspect. We did one installation last year we had error 04 for the 5 kW Inverter (IVEM) and the 170 Ah / 48V at panel voltages higher than 270 V (for 450 V maximum). We reported and were sent a software upgrade for the Inverters. Once we upgraded the software, the error was no longer there. I see it as a good move for the BMS regulation as you can still build charge at the other voltages.
Using a must 5kva inverter, it has inbuilt mppt. Using a generator to charge my felicity 7.2kwh lithium battery. Is there a device I can use to make the gen charge the battery easier. I use a 5kva generator. Thanks in advance
@diyfalke
Жыл бұрын
I assumed the inverter doesn't have inbuilt AC charger, or the AC charger current of the inverter is small. you can consider buying a 48v AC charger, check out these video by Will Prowse. kzread.info/dash/bejne/l4Wt2rVxZtuymMo.html
@mexossai7982
Жыл бұрын
@@diyfalke thank you so much
@mexossai7982
Жыл бұрын
@DIY Solar Power with Falke Amazing. Thank you very much. Pls quick question, how would I connect it so I do not need to unplug my current inverter to the battery. Thanks once again
@diyfalke
Жыл бұрын
@@mexossai7982 I'm afraid you must disconnect the inverter, the chargeverter comes with Seamless Crimp (SC) Lug. What worries you about disconnecting the inverter? You can chat me up, my WhatsApp is on the about tab.
What is the reliability of Felicity batteries and the grade of the batteries cells?
@diyfalke
Жыл бұрын
I have had this for only 10 weeks, so far there no single issue, the main issue many had with Felicity batteries is the overrated capacity. They have another series made for European customers, these could definitely have greater build quality, more accurate capacity rating and probably better BMS due to the low temperature in the winter.
@caniceonuoha
Жыл бұрын
@@diyfalke given your experience, would you advise someone to go with Felicity for a 75KVA buildout or look elsewhere for other batteries
@diyfalke
Жыл бұрын
@@caniceonuoha I take it you mean 75KWH battery bank. If so, I will say it depends on the budget and location of use. Compared to other brands like Pylontech, EG4, and BattleBorn etc, Felicity cost a fraction of these brands, the Felicity LPBF series have greater value for money, I will hardly recommend the LPBR series to anyone. The LPBA series are in the same league with EG4 in the price range, amongst the two, I will always go for EG4. Even the Felicity LPBF series have two or more class, one promising >=3000 cycle, the other 6000 Cycle.
@caniceonuoha
Жыл бұрын
@@diyfalke thank you. I didn’t know that EG4 is available in Nigeria.
@caniceonuoha
Жыл бұрын
@@diyfalke hi I sent you mail
I need a contact to one of your professionals
@diyfalke
Жыл бұрын
I'm sorry you are having difficulty with your setup, however I do not work with Felicity solar, nor in anyway affiliated to them. But i will be more than happy to help you in any way I can.
My inverter stop reading pv and dosent supply current but wen I put on my Account charge the inverter will supply current
@diyfalke
Жыл бұрын
sorry, your question is not clear.
@laurabarnes3295
Жыл бұрын
Inverter goes off when you put it on. It goes of after a minute even wen de is no load ,and if you put panel it dose not show either
How long can this battery serve ?
@diyfalke
Жыл бұрын
It can serve you upto 3000 cycles @80% DOD before the capacity decays to 80%
@davidniquot6423
Жыл бұрын
@@diyfalke They are given for 2000 cycles and aging give 80% capacity after 11 years. (CATL FFH3D3)
@diyfalke
Жыл бұрын
@@davidniquot6423 I believe if a manufacturer can lie about the capacity, they can be lying about other things, and I only see the datasheet of CATL FFH3DS, which has >=3500 cycle life.
@chuksobi593
Жыл бұрын
@@diyfalke trust me if they use catl cells in those, it will cost way more
Hello bros, how many hours backup time will Felicity 5KWH/24V LITHIUM BATTERY power 550watt load.
@diyfalke
Жыл бұрын
To calculate backup time for 5KWH battery, you first decide the depth of discharge (or usable capacity) say Felicity recommend 80% DOD, which means the usable capacity is 5000Wh * 0.8 = 4000Wh. This means you can run a load of 4000w for an hour. 2. If the load of 550w is including the inverter no load consumption fine, else add the no load power consumption to the load. This can be found in the inverter manual, or you can measure it with clamp meter. 3. Divide the total load(including no load consumption) by the efficiency of the inverter. Assuming 90% efficiency, that is 550w/0.9 = 611w. 4. Divide the usable capacity of the battery by the the load result calcilated in 3 above. That is 4000Wh/611w = 6.55h or 6h 33minutes. Summary. The Felicity 5KWH battery can safely run a load of 550w for 6h33min.
Felicity is a waste of money. Used old cells inside. No guarantee no maintenance even at Felicity service center
how do I contact you
@diyfalke
6 ай бұрын
My contact is on my about page