Blower won’t shut off
Found blower running, even when thermostat is off the wall. Board wasn’t getting a call for anything. I go through the things I know that may bring on the blower, and found no reason for it to be on. Plus, I checked to see if it would operate normally without “fan” wire hooked up, and it wouldn’t.
#hvac
#rheem
#furnace
#repair
Пікірлер: 43
If you see this again, just pull the green wire off of the thermostat. If the fan goes off, it's the stat. If the fan stays on, its the board. Usually a stuck fan relay. Love you vids. Keep it up!!!
@OneManParade
2 жыл бұрын
Great tips! I have to remember that.
@guillemrivera3163
Жыл бұрын
Hi limit genius!!
@beginnertoexpertprohvac3676
Жыл бұрын
Just had this issue and it was the board...thanks for the shortcut
@carlosmatamoros4447
7 ай бұрын
What if it’s a ecm motor?does it work same way I disconnected the g wire and it still ran but those run off 110v the 24v kills it on and off so I’m kinda confused on that I’m still learning service can you recommend if it’s the same for all motors ?
If I was in your area I would try very hard to work for you. I respect your ethics, the way you treat your customers, and your work.
@HVACGUY
3 жыл бұрын
Thanks 🙏
1:54 that’s usually how i fix shit; stab at it until it works (or doesn’t)!
Had one last week, problem was a loose nut in front of the thermostat 🤣
You know you're in the south when there's a rifle in the closet you're working in and nobody bats an eye.
@FrankRuiz66
Жыл бұрын
Up in NYC a shotgun would mean a phone call to the local precinct and they'll deploy a swat team. Here in Tennessee, the officer comes to the door and asks if you have any firearms. My answer always is hell Yeah lol
Can someone please help me... my furnace won't cut off once reached desired temperature BUT when I blow the fuse it'll work normal for about 30 minutes then it runs until I turn breaker off!!! Help!!!
theres always a dog supervising
Contactor or limit switch, high or low.
How much to fix the board? Thanks!
Out of curiosity what would happen if the cooling fan terminal was energized at the same time?
@HVACGUY
3 жыл бұрын
If both were energized at the same time, it would burn up the motor.
Or like that one guy said, they could have it on fan only, instead of automatic on the thermostat.
@HVACGUY
3 жыл бұрын
Thermostat was on the floor
why am I getting full length commercials before the video starts.
can you l=hook up a hard start two wire on your next job sir? I would appreciate it
@HVACGUY
3 жыл бұрын
Next time I hook one up I’ll try and explain
Is that gas line galvanized? Black pipe only with our gas companies
@HVACGUY
3 жыл бұрын
I try to only use galvanized. Especially outside, underground black iron won’t pass code
Is that a ECM motor for the blower
@HVACGUY
3 жыл бұрын
No it’s psc
I’m a guessing all the dust and dirt played a part.
@HVACGUY
3 жыл бұрын
No, it was psc
I woulda bet that was going to be a limit
@justinbelleville1392
3 жыл бұрын
How so if you don’t mind me asking? New tech.
@97Napkins
3 жыл бұрын
@@justinbelleville1392 main limit switches break 24 volts and some circuit boards run the fan when this happens
@---RON----
Жыл бұрын
@@97Napkins when the limit switch resets will the blower shut off?.
@97Napkins
Жыл бұрын
@@---RON---- yup
@---RON----
Жыл бұрын
@@97Napkins thanks for your reply
What kind of rifle was that? Lol
@bill944
3 жыл бұрын
Loaded
@johngraves2968
3 жыл бұрын
DIDN'T SEE NOTHING.
Cool place to keep a rifle.
poor neglected rifle sitting in the corner collecting dust ,not even a gun sock on it
When in doubt throw it out!😐 Leave the subtitles up a little longer I'm a slowski!🤔 🥃🍺🥃🍺🍺🏌🍇 Stay safe. Retired(werk'n) keyboard super tech. Wear your safety glasses.
@HVACGUY
3 жыл бұрын
Im not sure I know how. I’ll look and see if there’s some kind of timer I can manipulate.
@cathleenbaldwinmaggi2252
2 жыл бұрын
You can change the speed the video plays to a slower speed and have more time to read. Click the 3 dots in the corner when on the video and change speed.
@toofabuloussixt.v.6730
Жыл бұрын
Or pause the video