Birring NDT Class 202, Ultrasonic Testing # 4, Angle Beam Shear Wave UT as per AWS D1.1

NDT Class 202. Birring NDE Center is a NDT school in Houston that provides NDT training as per SNT-TC-1A. For training info see www.nde.com

Пікірлер: 33

  • @bootygoblin784
    @bootygoblin7848 жыл бұрын

    I just left the school and spoke to him, seems like a great guy and the courses seem top notch. looking forward to starting class with you sir.

  • @vkotes
    @vkotes11 жыл бұрын

    Excellent! very clear, simple, comprehensive.....hats off sir

  • @renellharris3109
    @renellharris310911 жыл бұрын

    best video i seen in a while

  • @alexclarosfernandez8467
    @alexclarosfernandez84679 жыл бұрын

    I am learning an humungus bag of knowledge from your videos!!!. Great job Mr. Birring. Clear and precise explanations.

  • @awsali3859
    @awsali38599 жыл бұрын

    Very Good Anmol. Thanks. Aws Ali

  • @chandan2sinha
    @chandan2sinha3 жыл бұрын

    Thank You sir for such a nice explanation

  • @jonhouck4981
    @jonhouck49813 жыл бұрын

    This guy is fantastic

  • @multiBuhdda
    @multiBuhdda7 жыл бұрын

    thank you

  • @nagrajm7369
    @nagrajm73696 жыл бұрын

    excellent sir

  • @user-charlieccchong
    @user-charlieccchong10 жыл бұрын

    Thanks

  • @pizote4797
    @pizote47974 жыл бұрын

    Mr. Birring, thanks a lot. Thats very well explained. I am just curious if that calculated severity class A, B, C or D shall be mentioned in the UT report. Our NDT contractor issued an UT report where he did not fill in a, b, c and d and stated the testing is acceptable. Not sure whether this is okay.

  • @sudheeshkavalam
    @sudheeshkavalam3 жыл бұрын

    Can u show the settings of ultrasonic machine for doing various inspections

  • @sugarforres6947
    @sugarforres694711 жыл бұрын

    Sir, appreciate your basic NDT AWS D1.1 i just want to know how you will calulate the 2nd leg, for example we have 25mm thickness plates with Butt weld joints or T-joints joints, now the indication from top surface is 15mm what formula we are using for calculation to get the exact depth of indication...thank in advance for your answer..

  • @tanveerahmed6525
    @tanveerahmed65254 жыл бұрын

    Thanks a lot sir God bless you very Easy and Interesting Can you plz provide reference for reference Echo why we need to take 50 % of FSH Why not 80% of FSH . THANKS

  • @tuanbuihuynh6108
    @tuanbuihuynh61088 жыл бұрын

    Stunning training! however, could you explain more a bout the Notes accompanied with the Table 6.2 AWS D1.1? When do we apply these notes?

  • @Qualitytestinglaboratories

    @Qualitytestinglaboratories

    7 жыл бұрын

    Tuan Bui Huynh

  • @souravbohrays4189
    @souravbohrays41892 жыл бұрын

    Incredible

  • @anmolbirring6341

    @anmolbirring6341

    2 жыл бұрын

    Thanks

  • @hugovelez8673
    @hugovelez867310 жыл бұрын

    very good, the best video..

  • @anoojnarayananp6059
    @anoojnarayananp60593 жыл бұрын

    Sir, Excellent Presentations . Can we do UT on PJP weld joints , if can ,how one can make the difference between PJP and CJP by doing UT, AND do you conduct UT Certification for AWS D 1.1 and TKY joints

  • @johnochocooliver9833
    @johnochocooliver98334 жыл бұрын

    What if you are using mm?

  • @akashsain5294
    @akashsain52943 жыл бұрын

    Dear sir please explain about TVG WHAT IS AND HOE TO USED?

  • @Qualitytestinglaboratories
    @Qualitytestinglaboratories7 жыл бұрын

    good

  • @prajaktpathak4645
    @prajaktpathak46455 жыл бұрын

    Nice very nice

  • @hasirrangdhanu8905
    @hasirrangdhanu8905 Жыл бұрын

    If the metal path is 1" than C = 0. In this case what is the calculation?

  • @silambarasank3795
    @silambarasank37956 жыл бұрын

    Dear sir, as per was D1.1 mentioned sensitivity calibration required 80% but are telling 50% fsh .please clarify.need 80% fsh or 50%fsh.

  • @ranjeetsinghchauhan8153

    @ranjeetsinghchauhan8153

    3 жыл бұрын

    No bro code hv mention 40% to 60% on calibration

  • @chanthasavann
    @chanthasavann4 жыл бұрын

    hello teacher

  • @pramodk4292
    @pramodk42926 жыл бұрын

    Hello Sir Can we do UT of fillet joint???

  • @vysakh3894

    @vysakh3894

    5 жыл бұрын

    Can't do it

  • @PraveenKumar-gy1uw

    @PraveenKumar-gy1uw

    5 жыл бұрын

    Then how to inspect

  • @regrettoinformyou424

    @regrettoinformyou424

    3 жыл бұрын

    @@PraveenKumar-gy1uw Visual inspection / MT or PT

  • @tsundar9091
    @tsundar9091 Жыл бұрын

    a-b-c , should be changed (a shall be reference ,b shall be indication, c- atteniation) ,for eg., if MP from discontinuity dB is at 72 & reference dB is 58 & C -2, then it becomes +12, which is small discontinuity and become acceptable. But in actual it is large. So it shall be 58-72-2 = -16 , Hence it becomes Class A and reject straight away., which should be the right way of doing it. Conclusion, if the amplitude from indication is increasing ,it should end up as large discontinuity ,and no small discontinuity