No video

BIGGEST DIY Mistakes with Downlights

Common mistakes DIYers make with downlights in homes.
Amazon Affliate links for great electrical tools:
- Wera insulated screwdriver - amzn.to/3Ezk06L
- Knipex Cable Shears (uninsulated) - amzn.to/3GeG0nC
- Stanley FatMax Automatic Wire Strippers - amzn.to/3Z9pRbB
- Draper Expert Insulated Side Cutters - amzn.to/3Cns6y8
- WAGO 221 regular - amzn.to/3wnnaGe
- WAGO 221 straight - amzn.to/3wjREZG
- IDEAL SpliceLine In-Line Connectors - amzn.to/3HndL7K

Пікірлер: 95

  • @muhammadsalah2063
    @muhammadsalah20636 ай бұрын

    Thanks buddy for all the videos. I really enjoy the tips and advice. Very thorough and eloquently explained. Thanks again.

  • @TheDiligentDIYer1759

    @TheDiligentDIYer1759

    6 ай бұрын

    Glad you like them! Thanks for watching!

  • @pb871
    @pb871 Жыл бұрын

    Another great video George. Concise and simply explained without excessive waffle!

  • @TheDiligentDIYer1759

    @TheDiligentDIYer1759

    Жыл бұрын

    Glad you enjoyed it!

  • @_tmmy_
    @_tmmy_ Жыл бұрын

    We had an electrician / bathroom fitter in to do our bathroom 6 years ago and I can honestly say as a DIY electrician the wiring for the spots was absolutely appalling - single cores exposed and junctions made without any kind of enclosures and insulation tape used rod the earth wires. It’s surprising how many rogue electricians you get these days and then people instantly blame the DIYer for being responsible

  • @TheDiligentDIYer1759

    @TheDiligentDIYer1759

    Жыл бұрын

    Yep you are absolutely right, plenty of ‘professionals’ out there making the same mistakes

  • @williamdgmartin

    @williamdgmartin

    Жыл бұрын

    Why didn't you do it yourself?

  • @chrisardern4594

    @chrisardern4594

    Жыл бұрын

    I wish I was a kitchen fitter the things I would tell people I could do better then a qualified tradesman would astounded them. But I'll have to stick with being a Electrician and having to go around fixing kitchen fitter electrical cockups. 😂😂😂

  • @cuebj

    @cuebj

    Жыл бұрын

    That trumps my experiences. All registered professional recommended electricians I've used have been sloppy with terminations working loose, exposed wires, etc, but none as bad as you describe... hang on, just remembered a good one from 1989 and a really bad error from 2018. Always have to check their work and, usually, have to fix it

  • @Innateintelligence

    @Innateintelligence

    10 ай бұрын

    Does the downlight for bathrooms need to be just fire rated or ip65 rated?

  • @PraiseandWorship205
    @PraiseandWorship2052 ай бұрын

    Thanks for this video and the clear explanation. I have the exact same lights in my bathroom, the IP65. I've been struggling trying to get the bulb out, but no luck. I ended up giving up as 2 needs changing. What l didn't realise is that l need to change the whole unit. I can't thank you enough. Finally, I'll get those lights changed. Thanks alot

  • @TheDiligentDIYer1759

    @TheDiligentDIYer1759

    2 ай бұрын

    Glad it helped! Thanks for watching!

  • @markgb9227

    @markgb9227

    11 күн бұрын

    Hi I have two blown Saxby 73787 ShieldECO IP65 spot lights, I have bought replacements from amazon, they have the whole unit and black part, can I just swap these out without turning off all the power to the flat, they are push connectors. Thank you.

  • @gerryslater4297
    @gerryslater4297 Жыл бұрын

    Excellent video. Always remember; Lamps glow, bulbs grow. 😊

  • @TheDiligentDIYer1759

    @TheDiligentDIYer1759

    Жыл бұрын

    Yes! Thank you!

  • @6panel300

    @6panel300

    Жыл бұрын

    Light Bulb is also the name of what only electricians call a lamp. The word light is put in front so electricians don't get confused. Everyone else is happy to just say bulb as they know what they mean. If you go in many diy shops etc they are labelled as bulbs as are many of the packs that the said bulbs come in.

  • @gerryslater4297

    @gerryslater4297

    Жыл бұрын

    @@6panel300 That’s a rather snotty reply, winkle. Many things have an incorrect generic name… but that doesn’t make those names correct. It was a light-hearted response to someone who has made video on an electrical subject. You, are most definitely the type of person I get caught behind in an electrical wholesaler. Asking for ‘double plugs’, ‘wire’, ‘fuses’ and ‘bulbs’. That little knowing look you get from your server, is the look that you shouldn’t be there and will get charged through the nose for your naivity Sniggers all round from trained people who you are holding up in the queue. Please don’t ever buy a ‘fuse box’ you’ll bring the house down. Stick to DIY, son and lighten up.

  • @briwire138

    @briwire138

    Жыл бұрын

    Years ago in the factory where I worked, I took a blunt drill to our machine shop and asked the turner if he could sharpen it for me. He said he couldn't and made a big deal about it saying he could grind it, telling me that you sharpen a pencil and grind a drill. Not long after the same fella came to me for a bulb for his lathe light. You can imagine the fun I had putting him straight. Initially I told him to go to a garden centre for his bulb.

  • @errolmagill1611
    @errolmagill1611 Жыл бұрын

    As always a very useful explaination, thanks for taking the time; without knowing you will be saving people much grief.

  • @TheDiligentDIYer1759

    @TheDiligentDIYer1759

    Жыл бұрын

    Thank you!!

  • @MarcusT86
    @MarcusT86 Жыл бұрын

    Good channel buddy. Hope you keep making vids!

  • @TheDiligentDIYer1759

    @TheDiligentDIYer1759

    Жыл бұрын

    Thanks, will do!

  • @johnriggs4929
    @johnriggs4929 Жыл бұрын

    Thanks for this... not sure about our bathroom downlights - they're all 12v but not IP rated in any way.

  • @TheDiligentDIYer1759

    @TheDiligentDIYer1759

    Жыл бұрын

    Thanks for watching! If they’re 12V, i dont think the IP rating rules apply

  • @MarkUKInsects

    @MarkUKInsects

    Жыл бұрын

    @@TheDiligentDIYer1759 Correct. But personally I wouldn't want to mix electricity and water at low voltage, may be safe, but it will soon look a horrible gungy mess

  • @markgb9227
    @markgb922711 күн бұрын

    Hi I have two blown Saxby 73787 ShieldECO IP65 spot lights, I have bought replacements from amazon, they have the whole unit and black part, can I just swap these out without turning off all the power to the flat, they are push connectors. Thanks you.

  • @TheDiligentDIYer1759

    @TheDiligentDIYer1759

    8 күн бұрын

    I can’t say without seeing it really. I would advise against trying to change fittings without turning off the power. Thanks for watching!

  • @glenmiles6279
    @glenmiles62794 ай бұрын

    Thank you mr beckham👍

  • @TheDiligentDIYer1759

    @TheDiligentDIYer1759

    4 ай бұрын

    Not sure I get the joke haha, but thanks for watching!

  • @pjmorgan
    @pjmorgan Жыл бұрын

    Great video. Worth pointing out that the CPC is generally always single insulated.

  • @TheDiligentDIYer1759

    @TheDiligentDIYer1759

    Жыл бұрын

    Good point! Thanks for watching!

  • @TheOvenCook

    @TheOvenCook

    Жыл бұрын

    Not for long, thankfully! New regs next year

  • @pjmorgan

    @pjmorgan

    Жыл бұрын

    @@TheOvenCook just for England and Wales. I hear Scotland are going mineral insulated of all things. Northern Ireland looks like it'll take up the same LSOH regs as Rep of Ireland.

  • @dazfrench
    @dazfrench8 ай бұрын

    I've got these exact lights in my living room (ip65) 4 of them, however when switched on the last light on the run takes two to three seconds later to light up than the others, hopefully someone can explain what's going on.

  • @TheDiligentDIYer1759

    @TheDiligentDIYer1759

    8 ай бұрын

    That sounds like a fault with the light unit rather than the wiring. If you’ve still got the receipt I’d try take it back and get another. Thanks for watching!

  • @acespark1
    @acespark1 Жыл бұрын

    The earth or CPC carries current under fault conditions. One of the first tests carried out when electrical testing , is continuity of the CPC. So never cut it off always connect it. In the end it's your house and you do as you see fit. But if you want to sell it, the electrical system must comply with building regs and BS7671

  • @TheDiligentDIYer1759

    @TheDiligentDIYer1759

    Жыл бұрын

    Yes good point. Thanks for watching

  • @lawrenceogden3736
    @lawrenceogden3736 Жыл бұрын

    Great channel glad I found it

  • @TheDiligentDIYer1759

    @TheDiligentDIYer1759

    Жыл бұрын

    Welcome aboard!

  • @fodayconteh9281
    @fodayconteh9281 Жыл бұрын

    Thanks for your explanation

  • @TheDiligentDIYer1759

    @TheDiligentDIYer1759

    Жыл бұрын

    Thanks for watching!

  • @gibberingidiot
    @gibberingidiot Жыл бұрын

    As an electrician, I'd like to say well done for covering a lot of stuff that even other electricians get wrong! Only thing that you maybe could have added is the issue of insulation over downlights, which used to cause any number of melted fittings in the past. It's mostly solved now with modern LED fittings that are built to allow insulation directly over the top, but not all are so something to check. The fire rating thing is not quite as simple as having a habitable room above either, since its related to the fire resistance of the ceiling you are fitting to - and in most houses the downstairs ceiling is not considered a fire barrier. However, it's always safer as you say to fit fire rated ones, and the vast majority are now, so no real reason not to use them these days.

  • @TheDiligentDIYer1759

    @TheDiligentDIYer1759

    Жыл бұрын

    Thank you, very appreciated from a professional! Thanks for the info on the fire ratings

  • @tellitasyouseeit7555

    @tellitasyouseeit7555

    Жыл бұрын

    And the building standards are different in Scotland.

  • @tellitasyouseeit7555
    @tellitasyouseeit7555 Жыл бұрын

    George, you mentioned all downlights in ceiling above shower or bath should be a minimum of IP44. However zone 1 and 2 heights are 2.25m which is lower than most ceilings of 2.4m. which means the lights are out of zones, therefore do not need to be IP rated.

  • @TheDiligentDIYer1759

    @TheDiligentDIYer1759

    Жыл бұрын

    True, but most baths and showers aren’t floor level, they are usually raised off the floor, so you’ll lose some height to that anyway, which could easily be 15mm. So safest to just use IP rated anyway, in my opinion.

  • @tellitasyouseeit7555

    @tellitasyouseeit7555

    Жыл бұрын

    @@TheDiligentDIYer1759 It wasn't your opinion that you were stating in your blog, you stated the zones tell you to use IP44 or IP65 which is not correct. So your 15mm will bring you closer to ceiling but that still gives you 135mm away from the requirement to use IP rated lights.

  • @jameshansing5396

    @jameshansing5396

    3 ай бұрын

    IPX4

  • @tellitasyouseeit7555

    @tellitasyouseeit7555

    3 ай бұрын

    @@jameshansing5396 Do you know what IPX4 is? Ok

  • @jameshansing5396

    @jameshansing5396

    3 ай бұрын

    @@tellitasyouseeit7555 yeh I do, hence it's IPX4

  • @reecehorner3736
    @reecehorner3736 Жыл бұрын

    Good Video, the big question is should people be attempting electrical work if not competent, When as a competent and registered electrician I conduct an EICR, I absolutely dread seeing down lights within the property because I know through experience there is a 90% chance they will of been installed but someone who isn't trained or competent, It works so it must be safe, 😅

  • @TheDiligentDIYer1759

    @TheDiligentDIYer1759

    Жыл бұрын

    Thanks for watching!

  • @reecehorner3736

    @reecehorner3736

    Жыл бұрын

    ​@@TheDiligentDIYer1759 It's great you put this out there, I appreciate you are showing this in simple terms

  • @kingofthetrowel1725

    @kingofthetrowel1725

    Жыл бұрын

    Reece I thought DIYers are not allowed to touch any electrical work , as how can they issue a minor works certificate or EIC 🤷‍♂️ but everybody just fits there own stuff. I darent touch any electrical things now (although I am confident) don’t get me wrong I wouldn’t know a good Zs or PFC if it smacked me in the face, but I could wire up a light fitting. But as said I’ve always been told not allowed to touch so there fore I pay an electrician to do everything, even changing a socket as same again I could do it myself but I can not test or issue a certifiacate. Annoyingly I have employed a registered spark in the past that was terrible with the job and never gave any paperwork and he was a registered qualified electrician 🤔

  • @reecehorner3736

    @reecehorner3736

    Жыл бұрын

    King Of the trowel, Diyers can do electrical work and no certification is required providing the circuit hasn't been altered, Bit of a grey area that one. Generally considered like for like replacements or simple repairs. Part P or Minor works can still be carried out providing certification is issued, as I understand the local council can arrange this for a fee, Obviously a registered Spark can self certify so saves that hassle, But you can't police anyone in there own home and people who want to will do.

  • @kingofthetrowel1725

    @kingofthetrowel1725

    Жыл бұрын

    @@reecehorner3736 yea that’s what I thought, so am I right I thinking that an eicr would test and check everything anyway as in for eg I’ve fitted my own decorative light fitting replacements and socket fronts , even tho I don’t have any minor works certificates will it all be checked in an eicr

  • @stuarthancock2206
    @stuarthancock2206 Жыл бұрын

    Lamps in fittings bulbs in the ground👍🙄

  • @TheDiligentDIYer1759

    @TheDiligentDIYer1759

    Жыл бұрын

    Not a spark, go easy on me!

  • @bartokglasgow

    @bartokglasgow

    Жыл бұрын

    Lamps glow, bulbs grow!

  • @TheGhost-gx5vd
    @TheGhost-gx5vd11 ай бұрын

    I'm a retired spark those push fit down lights i find are absolute rubbish the wires won't stay in what is wrong with the screw terminals or wago type

  • @TheDiligentDIYer1759

    @TheDiligentDIYer1759

    11 ай бұрын

    I haven’t had any problems with these, but I do agree they aren’t a good terminal type. Thanks for watching!

  • @jameshansing5396

    @jameshansing5396

    3 ай бұрын

    Push em in properly then, maybe that's why you're retired. Never had an issue with push fit...

  • @pjmorgan
    @pjmorgan Жыл бұрын

    I wonder how many building control offices have ever been notified about work in zones one or two? 😂

  • @TheDiligentDIYer1759

    @TheDiligentDIYer1759

    Жыл бұрын

    Hahaha good point, I doubt it is frequent

  • @snaplove7931
    @snaplove79315 ай бұрын

    so is a IP65 ok over a shower

  • @TheDiligentDIYer1759

    @TheDiligentDIYer1759

    5 ай бұрын

    Yep it is

  • @michaelprosperity3420
    @michaelprosperity3420 Жыл бұрын

    I use cans either remodeling or new construction. These new lights are dangerous and the bulbs aren't replaceable

  • @TheDiligentDIYer1759

    @TheDiligentDIYer1759

    Жыл бұрын

    Thanks for watching

  • @mountain01able
    @mountain01able10 ай бұрын

    Much better to connect twin and earth into a joint box and wire downlights in heat proof flex

  • @TheDiligentDIYer1759

    @TheDiligentDIYer1759

    10 ай бұрын

    I think it depends on the terminations the light comes with, if only a tiny block, then I absolutely agree, but if they have substantial terminals for two cables, I think it would be unnecessary. Thanks for watching!

  • @TheChipmunk2008
    @TheChipmunk2008 Жыл бұрын

    That diagram is incorrect... There is no zone around a hand basin

  • @TheDiligentDIYer1759

    @TheDiligentDIYer1759

    Жыл бұрын

    Whether there is it isn’t a zone around a hand basin, it would still be a silly place to put anything electrical that wasn’t IP rated

  • @TheChipmunk2008

    @TheChipmunk2008

    Жыл бұрын

    shaver sockets are often put within that fictional area

  • @mb63
    @mb63 Жыл бұрын

    Ip DOES NOT STAND FOR INGRESS PROTECTION. IT STANDS FOR “INTERNATIONAL PROTECTION”.

  • @TheDiligentDIYer1759

    @TheDiligentDIYer1759

    Жыл бұрын

    In the context of water protection, it is ingress protection

  • @tellitasyouseeit7555

    @tellitasyouseeit7555

    Жыл бұрын

    @@TheDiligentDIYer1759 yes this is correct in Europe and uk

  • @markwilliams1650
    @markwilliams1650 Жыл бұрын

    Please stop encouraging DIYers to carry out their own electrical work.

  • @TheDiligentDIYer1759

    @TheDiligentDIYer1759

    Жыл бұрын

    Remember to like and subscribe!

  • @jameshansing5396

    @jameshansing5396

    3 ай бұрын

    Nah let em fuck it up so we can charge more for an emergency callout and repair when it goes wrong. f*ck em! ;)

  • @prav1976

    @prav1976

    2 ай бұрын

    Please stop encouraging humans to do anything on their own

  • @MrManningata

    @MrManningata

    Ай бұрын

    On a simple job like this, it is fine to do your own electrical work. If you watch video tutorials such as this one, and read up on it, I don't see why you should have to hire an unreliable sparky who may or may not do the work to a good standard.

  • @openquote
    @openquote Жыл бұрын

    Hi George - what's the best way to reach you. I'm the founder of OpenQuote and I'd love to chat. (We're building software to try and improve the process of providing job information to tradesmen). Happy to explain more.

  • @TheDiligentDIYer1759

    @TheDiligentDIYer1759

    Жыл бұрын

    Hi, sorry for the delay, I needed to create an email address. I've added it to my bio. thediligentdiyer@outlook.com

  • @rogerdavid3297
    @rogerdavid3297 Жыл бұрын

    if you are really are a time served spark, as i was.then you would never call a lamp a bulb. that is the talk of a diy spark for me. apart from that your video was good.

  • @TheOvenCook

    @TheOvenCook

    Жыл бұрын

    Big up yourself

  • @TheDiligentDIYer1759

    @TheDiligentDIYer1759

    Жыл бұрын

    Thank you. I’m not a spark, just an over enthusiastic DIYer

  • @tellitasyouseeit7555

    @tellitasyouseeit7555

    Жыл бұрын

    @@TheDiligentDIYer1759 which can be dangerous posting videos with incorrect information.

  • @StuartCarolyn

    @StuartCarolyn

    Жыл бұрын

    Clearly not a spark, and you should make that clear because there are a few things badly explained (and wrong) that could be dangerous followed. CPC = Circuit Protective Conductor so it DOES carry current under a fault or leakage. Also. what you're saying at 2.43 is nonsense. It's not a "much higher risk of shock" and if you knew why, you wouldn't be saying this.