Atlas copco |GA 160| Unloder valve

How to service GA 160 unloader valve

Пікірлер: 9

  • @neimarsantossantos200
    @neimarsantossantos2002 жыл бұрын

    Demostração desta desmontagem muito boa.

  • @mnairengineering1985
    @mnairengineering1985 Жыл бұрын

    Nice

  • @tuananhvo7744
    @tuananhvo77442 жыл бұрын

    hi guys, i dont understand how unloader valve (UV) working, and when we build a new compressor, the pressure of Oil Separator is Zero, and how the plunger of Unloder Valve can move down without pressure, thank you very much

  • @aliali-hp1wj

    @aliali-hp1wj

    2 жыл бұрын

    i will explain it to you i read it before . there is air pipe coming from receiver and enter the solenoid valve when the receiver maximum pressure the air solenoid valve open the air pass throw blow off valve and open it . and then to unloader .that air will push up the piston of unloader .when the piston up it will prevent air to enter element . the plunger can move down by element vacuum .

  • @ansarihameed5813
    @ansarihameed58134 жыл бұрын

    Ga160 compressor problem . compressor showing load but not buildup pressure.running 2 minutes after going shut dowm

  • @srpneumaticservices1918

    @srpneumaticservices1918

    3 жыл бұрын

    Please check the solenoid valve and coil,....

  • @tenkteonkic9299
    @tenkteonkic9299 Жыл бұрын

    I need partnumber for bushing tools,can anyone please help me.

  • @global-tech3203
    @global-tech32032 жыл бұрын

    Hello

  • @Aircompressor6064

    @Aircompressor6064

    Жыл бұрын

    Yes