APFC Panel wiring diagram in Hindi //How to do Wiring of Auto Power Factor Correction Panel ?
Ғылым және технология
APFC Panel wiring diagram in Hindi //How to do Wiring of Auto Power Factor Correction Panel ?
This video is about APFC panne wiring diagram detail explanation. I hope you will like this video qnd you will get some useful knowledge about automatic power factor control system.
Our othervideos :
• godown wiring in hindi...
• what is air circuit br...
• Street Light panel का ...
Our facebook page :
/ jigyasaelectricals
We are on instagram also :
/ jigyasaelectrials
Topic shows in this video :
apfc panel
how to do wiring of apfc panel
apfc panel wiring diagram
apfc panel working
apfc panel control wiring diagram
power factor
what is power factor
power factor explained
apfc panel in hindi
working of apfc panel
capacitor panel
apfc panel wiring
power factor improvement
apfc panel circuit diagram
power factor improvement in hindi
APFC Panel Wiring Explained in detail
How to do Wiring of Auto Power Factor Correction Panel
Jigyasa electricals
#APFC
#Powerfactor
#Jigyasaelectricals
Пікірлер: 101
Veri veri good sir aise hi sir sapot karte rahe thanks sir
Brother your hindi explain is superb. I don't know hindi, but fully understand the everything.. Best wishes for keep up your good work..
Yutube per bahut se log control wiring diagram banakar dikha to dete hai lekin apke jaise Samjha nahi pate hai. Thank you very much 🙏
Beautiful sir🎉thanks for explaining
Vv nice bro
nice videos and good presentation keep up the good work make a more videos..
Supper clear voice and 100% very nice video.sir up ko hum 100000 like dediya
Wow!! So nice presentation
Very nice video sir
@JigyasaElectricals
11 ай бұрын
Thank you
Very nicely Explained 💯💯💯
Thenks. Appka. Bidio. Bahut. Acha. Laga
Very good presentation thank you sir
Good daigaram
Bhai aap ke jaisa vedio koi nahi banata Or v alalg alag type ke pannel ka wiring digram bato sir thnaks
Thank you sir. You are the mentor of us.
Excellent
Sir apne digram banakar bahut Achche tarike se samjhaya hai ki power supply kaise Kaise jayegi jiske karan Sara confusion dur ho gaya
Very good
Very good explanation
Superb one keep on explaining such concept which will clear our doubts easily
Thank you for valuable information..
Very clear good job well done
Clear Cut presentation...thank you.
Baah! Baah! You explained very nicely. Anyone can understand that. That's why, I demand to you a video on APFC Panel in where Thyristor is used. Please do that with 2d drawing and practically. Please please.
@JigyasaElectricals
2 жыл бұрын
Ok
Thanks 🙏
keep it up very nicely present the control wiring and actual display of APFC panle. Please make vdo on how to calculate the KVAr rating for PF from 0.5 to 0.99 to design APFC panel
@JigyasaElectricals
2 жыл бұрын
Ok I ll do very soon
@sunilsahu2525
2 жыл бұрын
Kvar = KW (tan@1-tan@2) Suppose pf1= .80 ansPf2=.0.98 Kvar = 100kw×{.060} = 60 kvar capacitor
@sumitsinghsumitsingh5724
8 ай бұрын
@@sunilsahu2525qqqqq
Very nice bro
Very nice
Sir Ek simocode based BDOL starter ki pawer and control wiring par video banaiye
@JigyasaElectricals
2 жыл бұрын
Ok bro
Good vedio very nice
Super bhai
Good explanation
Well explained
Nice sir
Kindly make a video of APFC program
Sir isme reactor ka use kyu kiya hai Uski kya jarur hai Pls uspe ak video banaaye
nice video... One thing that is missing ,auto contactor and manual contactor . In circuit diagram it is mentioned but in the real presentation of APFC it is missing.
Sir hamare yaha 20 kvar reactor lagaya he aur out put me 20 kvar L & Tsuper heavy duty 480 capacitor lagaya he hya. Kya me L &T ke jagah koi dusra 480 v ya 525 volt capacitor laga sakte he kyu ki L & T ka capacitor mil nahi Raha he kya me epcos ka use kar sakta hu??? Pls reply
Why capacitor duty contactor 3phase looping with add on block
@JigyasaElectricals
2 жыл бұрын
Ise demping resistor kahte hai. Smooth switching karane ke liye ham log iska istemal karte hain Kyunki Jab capacitor start hota hai to Jyada current leta hai aise Mein capacitor aur contactor donon ko hi damage hone ka khata rahata hai. Ye ek heavy duty contactar hai jo ki bhut costly aata hai. Isliye jab contactor me jyada current paas karta hai us samay ye current ko resistor karta hai jisase contactar jyada current flow hone par kharab hone se bach jata hai
1200 k v r ke bar me 1 video bano sir ji
@JigyasaElectricals
2 жыл бұрын
Sure
Sir app jo dekhayea power wiring samjgya... Control wiring practically samjhao
sir, 5 stage may work krayangay to kaya auto contactor ek hi denay say work kar kayayga
Sir Ghar k lea use kr sakta hai 7kva k load k lea .
Good
What if I have 4 capacitors how will I loop the A1 and A2 if the Mc and CDC Auxiliary
Nice
Sir power control panel ka video banayiye na please please please please please
@JigyasaElectricals
2 жыл бұрын
Ok I ll make
automatic mode pe relay se CDC ke A1 terminal pe direct connection nhi ho skti? qki CDC bhi contactor ke jesa hi to work karta h? agr hm capacitor bank lgate h to jis number ka relay on hoga us number ka CDC?
Bhut.khoob.sir.aap.kaha.work.karte.hai.
@JigyasaElectricals
3 жыл бұрын
Hyderabad,😊😊
sir jee mai electrician hu. bahut jagaha mai dekh raha hu. capacitor sehi hai, but reactor bahut heat hai. 1.reactor kiu heat hota hai 2.reactor se kiu sound ata hai 3.reactor test karneka prossess keya hai please sir KZread mai bahut search kiya nehi mila. mughe janna hai?
Please sir
Sir I have a question, capacitor is connected between the source and final load. How is it connecting to the final load
All circuit right but normally contactor besd. it mince. this work normal riley efinitely working ok. So auto an manual function opreting. this contractor very wrong.....
Mujeeb electric
Agar isme reactor nai lagaye ge to kya hoga???
Hello sir
@JigyasaElectricals
2 жыл бұрын
Hello
11kv power distribution system
PLC and cancer k bary me samja do
Neutral not connected with rely?
@JigyasaElectricals
2 жыл бұрын
Not required
Sr Copasitor panel to LV panel 2core ka wire kyu use hota hai kisakeliye
@JigyasaElectricals
Жыл бұрын
Good question . LT panel ke busbar ke CT se APFC relay ko connect karna parta hai.
@rajeshmahato4461
Жыл бұрын
@@JigyasaElectricals s1 s2
@rajeshmahato4461
Жыл бұрын
Thank you sr
Reactor k control wire ke bare mai nahi bole
Zakkkaaaaasssssss bossssss
Bhai aapse baat kaise karein?
O k
🙏🙏🙏🙏👍✅👌👌👌👌👌🖥️
Why CDC use...any special reason..why we cant use normal contactor
@JigyasaElectricals
2 жыл бұрын
It's damping inrush current of capacitor। मतलब जब capicitor स्टार्ट होता है उस समय वह अधिक मात्रा में करंट लेता है जिससे capicitor और normal कॉन्टैक्टर जल्द ही खराब हो जाता है। cdc में damping resistor होता है जो inrush करंट को रोकता है जिससे capicitor और कॉन्टैक्टर कि लाइफ ज्यादा दिन तक रहती है।
Hi
@JigyasaElectricals
Жыл бұрын
Hello
1. Jo humne input liya he MCB me , wo khaan se liya he aur Main supply se kaise connect krte he? Please sir clear this doubt .
@JigyasaElectricals
2 жыл бұрын
1 ans : apfc panel ka jo main incomer hai uske mccb ke output ke kisi bhi ek phase se MCB ka input. Le sakte ho.
@JigyasaElectricals
2 жыл бұрын
Ans 2 : main electric panel ke output se apfc panel ko supply jata hai
@zeeshanahmad7070
2 жыл бұрын
@@JigyasaElectricals iska matlab ki Capacitor directly main line se attached hoote he ( Via MCB and contactor )
@JigyasaElectricals
2 жыл бұрын
Main panel ke common busbar se ek feeder banao aur waha se cable ke through apfc panel ko le jaya jata hai
@zeeshanahmad7070
2 жыл бұрын
@@JigyasaElectricals Thanku very much sir U r the 1st one who replied
Mene " selec apfc 346 " relay use ki he ON krne prr fault aa rha he ' capacitor bank is not connected ' Iska kya meaning he ? Please Reply
@JigyasaElectricals
2 жыл бұрын
Ek baar wiring check kar ke dekho. Kahi per bhul connection hoga. .Full load ka kam se kam 20% load rahne per hi capacitor bank automatically start hota hai
@zeeshanahmad7070
2 жыл бұрын
@@JigyasaElectricals Sir Syd yahi problem he . Mera apfc panel 15 kw ka he aur me testing kr rha hu total 3 motor ( total 3 kw ) at no load , Meri apfc relay sahi work kr rhi he But thodi der baad "CURR: Phase current error " likha aa jata he
@zeeshanahmad7070
2 жыл бұрын
@@JigyasaElectricals Sir , Mene 30 kw ke apfc panel ko 5 kw ke load prr test kiya Power factor " 0.6 " se upar nhi jaa rha he aur all capacitor ON hoo gae What is the problem ? Please Reply
Manual Contecotar connection wrong
Menula me wiring rong hai
ek he phase wire se 2 supply pass out karwa rahe ho bhai ye nhi samjha aya 😂
@JigyasaElectricals
11 ай бұрын
Video time mention Karo please
Veri veri good sir aise hi sir sapot karte rahe thanks sir