All About Shelly RGBW2

Ойын-сауық

Rob Tait tells everything we want to know about Shelly RGBW2

Пікірлер: 31

  • @wwolfram33
    @wwolfram33 Жыл бұрын

    Very helpful. Thanks Rob!

  • @richardrostecky189
    @richardrostecky189 Жыл бұрын

    Does exist some possibility of connecting CCT led strip with the control channel (to control the temperature of white)?

  • @adogonasidecar1262
    @adogonasidecar12623 ай бұрын

    good video

  • @mauricioandrade5667
    @mauricioandrade5667 Жыл бұрын

    With RGBW 2 you can configure lighting scenes where the same LED strips change color for each scene and if I use different RGBW circuits, can I group them into scenes with different colors for each LED strip...?

  • @GlenKroese
    @GlenKroese Жыл бұрын

    I want to have the switch input act as an input signal instead of a master control. Is it possible to use the physical switch to act in this way? Nevermind, figured it out after rewatching the video (edge setting for button).

  • @shadow.banned
    @shadow.banned Жыл бұрын

    I now have a PhD in electrical engineering.

  • @Shelly_IoT

    @Shelly_IoT

    Жыл бұрын

    Rob doesn't play around when it is time to teach!

  • @JbVest

    @JbVest

    2 ай бұрын

    ​@@Shelly_IoT then can you PLEASE teach us how to use the RGBW2 to control CW WW with color temp? ive seen people do it but no tutorial on how to get it done

  • @allan.adimoolah
    @allan.adimoolah Жыл бұрын

    I bought this and it a black piece of wire that has a heat-shrunk hardware that is very small with a red and black wire at one end and 2 black wires at the other end... how does this connect and does it connect directly to 110v AC, the reason I am asking is because the wiring diagram has AC 110v connecting to the heat-shrunk hardware?

  • @uro7219
    @uro7219 Жыл бұрын

    Can you combine shelly rgbw2 with the physical PIR and how to to bind?

  • @andyh8239
    @andyh8239 Жыл бұрын

    Any option for two white channels (warm/cool) FiveSpect 5-in-1 LED Strip Lights

  • @danielsingh7211
    @danielsingh7211 Жыл бұрын

    I want to use an AC 230v light switch to control the lights . Where can I get the Adapter from ?

  • @adrie9236
    @adrie923610 күн бұрын

    If I want to have a physical dimmer, can I use a potmeter or does it have to be pwm?

  • @nikoaiello
    @nikoaiello10 ай бұрын

    I have a white stripe with touch on/off integrate it, from the led stripe inonly have 2 cables (-) (+) how can i configure this? Thanks

  • @donameti9052
    @donameti9052 Жыл бұрын

    It is necessary to connect all of the 4 LED single color strips or can it be use with two Cob LED 24v using only 2 channels?

  • @ha_tinkerer1191

    @ha_tinkerer1191

    Жыл бұрын

    You don’t need to use every channel.

  • @danielcourt7455
    @danielcourt74559 ай бұрын

    do shelly have any SPI Addressable Controllers

  • @danielpaulsen5945
    @danielpaulsen5945 Жыл бұрын

    If you are replacing an existing light can you switch the mains input to the power supply?

  • @andrewfidel2220

    @andrewfidel2220

    7 ай бұрын

    No, the RGBW2 is DC only.

  • @paulhimle
    @paulhimle Жыл бұрын

    … It’s Rob!!

  • @dmrservicegsmconstanta990
    @dmrservicegsmconstanta9903 ай бұрын

    good bro

  • @Scheremet
    @Scheremet Жыл бұрын

    becomes a shelly controller for addressable leds ???

  • @-willem

    @-willem

    Жыл бұрын

    Unfortunately not. Rob tells about it at 1:50

  • @JordanHaisley

    @JordanHaisley

    Жыл бұрын

    I think it could be done if someone wrote firmware for it, almost all of the addressable strips use SPI interface.

  • @fredericomachado4116
    @fredericomachado4116 Жыл бұрын

    I was under the impression that you could dim the lights via the push switch

  • @andrewfidel2220

    @andrewfidel2220

    7 ай бұрын

    You can if using a momentary switch instead of a toggle switch, long press can then dim or brighten.

  • @sintor887
    @sintor887 Жыл бұрын

    Bitte passt auf, Shelly hat wegen "smoother dimming" die maximale helligkeit auf 90% reduziert! Das heisst das bei 100% einstellung am Shelly rg w2 trotzdem PWM auf 90% verwendet wird. Dies ist ab version 1.7 so. Leider kein downgrade mehr möglich und kein licht ohne PWM. Shelly Support nicht hilfreich. Selber messen. Bin draufgekommen weil mein LEDsteifen am labornetzteil 196W aufnahm, und am shelly auf 100% nurmehr 157W.

  • @alifarhat300
    @alifarhat300 Жыл бұрын

    You should try supporting apple home kit and siri this way will increase your sales

  • @Raj-yy7xx

    @Raj-yy7xx

    21 күн бұрын

    HomeAssistant is far better and open.

  • @singhVarunVikram
    @singhVarunVikram7 ай бұрын

    dude this is horrible as a youtube channel but good if you were taking a class. Instead of talking schematics, much more sense to ACTUALLY have a PHYSICAL DC supply and wire and DO as you go along so people can understand what you are saying. HOrrendous teaching and tutorial skills. Think about it like this, if a surgeon who is renowned for his skills on a living body, showed you body schematics and explained what vein/artery goes where and the handed you a scalpel to do actual surgery, won't that be astronomically stupid ?

  • @Raj-yy7xx

    @Raj-yy7xx

    21 күн бұрын

    This really depends on your level of electrical knowledge. I thought it was a fantastic video, albeit I have intermediate electrical skill..the diagrams and usage cases were very clearly explained and much much better than the instructions that come with Shelly.