Alaris 8120 PCA Training

This video provides training on the setup and many functions of the Alaris PCA Pump Module of the Alaris System. The training includes programming an infusion, viewing patient history, connecting modules to the PCU, bolus request cord profiles, programming a bolus dose, selecting the right patient profile and more.
--------------------------------------------------
SUBSCRIBE: bit.ly/3iJG9oS
Request a Quote: www.medonegroup.com/equipment...
--------------------------------------------------
Follow Us
Instagram: / medonegroup
LinkedIn: / med-one-group
Twitter: / medonegroup
Facebook: / medonegroup
Website: www.medonegroup.com/
Equipment Inventory: www.medonegroup.com/equipment
------------------ Video Chapters ------------------
0:00 Intro
0:38 Overview of Alaris 8015 PCU
1:48 IUI Connectors
2:00 Connect PCA Module to PCU
2:13 PCA Module Overview
3:05 Tubing/Disposable Overview
3:19 Syringe Options
3:54 Prime Tubing
4:10 Insert Syringe into PCA Module
5:06 Profiles Explained
5:49 Infusion Start-Up
7:20 Programming Infusion
9:07 Dose/Bolus Request Cord Overview
10:59 Patient History
12:33 Programming a Bolus Dose
14:28 Near End of Infusion Alarm
15:12 Syringe Empty Alarm
16:25 Turning Pump Off
17:10 End Screen and Disclaimers

Пікірлер: 24

  • @sheilafernandes397
    @sheilafernandes3972 жыл бұрын

    You should have shown how the saline is primed and how it is attached to the patient. thank you.

  • @getflared
    @getflared3 жыл бұрын

    As a nursing student who has limited prac time, this is highly helpful in knowing exactly how to operate this device once I qualify as a Registred Nurse

  • @MedOneGroup

    @MedOneGroup

    3 жыл бұрын

    Thanks for your comments! We are glad you found our training video helpful.

  • @annoommen7278
    @annoommen72782 жыл бұрын

    I don't know how much thankful I am for you and your video.👍 Keep sharing and help others.thanks a ton!!

  • @MedOneGroup

    @MedOneGroup

    2 жыл бұрын

    We are so glad to hear that it was helpful!

  • @tammeramiller8165
    @tammeramiller81653 жыл бұрын

    Awesome In-service. Thank You!

  • @MedOneGroup

    @MedOneGroup

    3 жыл бұрын

    Thanks for your comment!

  • @yadirasorcini4462
    @yadirasorcini44622 жыл бұрын

    thank you soooo much for making this video!

  • @joycerineer7688
    @joycerineer7688 Жыл бұрын

    Excellent Valuable Instruction. Thank you

  • @MedOneGroup

    @MedOneGroup

    Жыл бұрын

    Thanks for the feedback and that you found our training useful.

  • @japonicaferrell208
    @japonicaferrell2084 жыл бұрын

    Awesome thanks

  • @truthmarshall4512
    @truthmarshall45124 жыл бұрын

    great teacher !!! you took your time and did a great job

  • @nishey94
    @nishey942 жыл бұрын

    So informative and helpful!! Thank you!!

  • @MedOneGroup

    @MedOneGroup

    2 жыл бұрын

    Thanks for your comment. Make sure you subscribe for more informational training videos on medical equipment.

  • @nerlyb7032
    @nerlyb70322 жыл бұрын

    Excellent!!! God bless you well done 🙏🏽👏🏽👏🏽👏🏽👏🏽👏🏽

  • @MedOneGroup

    @MedOneGroup

    2 жыл бұрын

    Thanks for your comment! We are happy you enjoyed this training video.

  • @jamesdavies7199
    @jamesdavies71993 жыл бұрын

    So when we chart the patient history, there is no need to ‘clear history’ each time we do so? That’s what every nurse has shown me in practice, but it seems like using the zoom function is better as the history is not erased.

  • @mrstanskaggs1
    @mrstanskaggs12 жыл бұрын

    can you give information on using the 8120 as an epidural pump in function?

  • @MedOneGroup

    @MedOneGroup

    2 жыл бұрын

    You can use the 8120 module for epidural use, but you must specifically use yellow striped tubing. The maximum amount you can give is 60ml, which is the size of the largest syringe the PCA module will hold. Typically, clinicians do not use this module for epidural use due to that limitation. If you have any more questions, feel free to call us at Med One or reach out to the manufacturer for more information.

  • @yingru1301
    @yingru13013 жыл бұрын

    Is it OK for not using the pump to prime the tubing? Thanks.

  • @MedOneGroup

    @MedOneGroup

    3 жыл бұрын

    Hello, thanks for your comment. You can manually prime the tubing as well.

  • @bernaaguirre1916
    @bernaaguirre19165 жыл бұрын

    Berna

  • @eagle7757
    @eagle77572 жыл бұрын

    For God so loved the world, that he gave his only begotten Son, that whosoever believeth in him should not perish, but have everlasting life. John 3:16 KJV, Jesus Christ is the only way.....