Aggregate Impact Value Test in Hindi || Impact Value (Crushing value) test in Site Laboratory
Aggregate Impact Value Test in Hindi || Impact Value (Crushing value) test in Site Laboratory
in this in this video I am telling about how to do the aggregate impact value test inside laboratory the whole process of aggregate impact value test will be explained in this video...
in simple and easy Language.
#impact_value,
#Aggregate_impact_value,
#Crusing_Value
Пікірлер: 103
8mm ki rod se tamping karte h sir esko ham
@CivilEngineerShubhamGupta
4 ай бұрын
Sorry I know this is a mistake.
@gautamkashyap5718
4 ай бұрын
@@CivilEngineerShubhamGupta koi nhi sir jo kaam karta h use se mistake' hoti jo nhi karta use kbi mistake nhi Hoti
Big Respect sir ap ny jis tarha step by step samjya hai aur formula lagna sikhya hai kya bat hai sir apki ❤❤
@CivilEngineerShubhamGupta
12 күн бұрын
Thank you 😊👍
very simple and easy explained .........thank u so much sir
Mere ko ye test malum nahi tha aapka video dekh ke aaj malum chala kaise karte hai ❤
Bhaiya apki calculation samjane ka tarika bahut accha hai
Aapko bahut bahut dhanyawad sir
Dhanyawad sir ji 🙏
Knowledge full video thanks
Thank you Nice explanation
Tq very helpful
Thank you Sir & respect your assistant ❤❤❤❤
@CivilEngineerShubhamGupta
5 ай бұрын
So nice of you
Very very nice 👍
Shukriya😇
Thank you sir lab work s
Thank u sir ❤
Sir jo 12.5 mm se pass 10 mm se retain ho usko oven me 4 hours ke liye dry hone ke liye rakhte hai sir
Thanks you sir
Grate post sir
Gajab sir
Thanks 🙏
Wao very nice sir🤔🤔🤔
Ty
Thanks bro
Helpful ..
Thik hai💯
Thik hai sir ...
Good sir💐💐👌
Mast bata rahe hai sir
Sir Very informative But i Have One Question... Sir 3 Trials K liay Jo Cement Sample Lena Wo 3 Alag Bags Mein Sy Lena Ha Ya 1 E Bag Mein Sy?
❤
Good 👍
Good sir
Good knowledge thank you sir
@CivilEngineerShubhamGupta
15 күн бұрын
So nice of you
excellent .Good job man
Mould ka size kya rahega
is code kaun sa hai aggregate k liye?
Sir sare test 10 mm aggregate ke liye hi karte h 20 mm ke liye impact test karke dikhaye plz
Civing kase karte hai
ये टेम्पिंग रॉड हम aiv में यूज नही करते सर आप बनाते रहिए वीडियो सही है भाई साहब 👍👍
@CivilEngineerShubhamGupta
2 жыл бұрын
I know but mere paas yhi available tha
@CivilEngineerShubhamGupta
2 жыл бұрын
Thanks for your feedback
@birendramishra5676
2 жыл бұрын
@@CivilEngineerShubhamGupta ya I know
Yeh to cube casting ka tamping rad he sir
Note 👉 Tamping road should be used as per is code 2386 part 4 clause 4.2 d which is written as below •Tamping Rod-A straight metal tamping rod of circular cross-section 10 mm in diameter and 230 mm long, rounded at one end. •The use of this small tamping road is to exert air from the cup and prevent aggregates coming out from the mould which is small in dimension.
@CivilEngineerShubhamGupta
Ай бұрын
Yes it's was a mistake.
Bhai mould kahte hai ese
Ek course nikaliye low fees me sir 😊
Thank you sir ❤❤❤❤❤😂
Iska is code kya hoga
Sir 10mm ka Kabhi test Hota hai
Name of instrument pls
Use correct tamping rod.. as per is code this tamping rod not acceptable..... Is code says the wait of sample min 350 to 370 gm
Nice video But 2386(p-4) ke according tamping rod ki size - 230mm long & 10mm dia hogi. Aapne crushing ka tamping rod use kiya hai & balance 0.1 g accuracy ka use hoga
Oven me dried nhi kiya 4 ghante ke liye
@mdsuhel1252
4 ай бұрын
Oven mai drai thab hota h jab aggregate gila ho
Empati 😀😄😁😁
15
16mm ki tamping rod impact value test me use Nahi Hoti Hai.
@CivilEngineerShubhamGupta
Жыл бұрын
Right i know but I don't have any other
@ravishkumarfanvlog
Жыл бұрын
@@CivilEngineerShubhamGupta right sir is ky lyea alag hota hai tamping rod 16 mm ki rod concrete or slmp
Iska tamping rood dusra aata hai Bhai ji
@CivilEngineerShubhamGupta
8 ай бұрын
Right
sir soil test ka bhi video dalo sir and cement test ka bhi Quality ke sare test video dalo sir
Ye jo test kiya tha aggregate 10 mm thi ya 20 mm
@chetanmanik7770
Жыл бұрын
20 mm
Sir What is the IS code
@akhileshsingh7897
Жыл бұрын
Is code 2386 part 4
Ye wrong method h aiv ka temping rod alag hota hai...cube bharne Wale se temp kar rahe hai...
@CivilEngineerShubhamGupta
8 ай бұрын
Right. Bro it was a great.
Tamping gat kiya gya hai sir
Yarr taymping rod kitna mm ka hai
@irfanshaikh-mx1qy
2 күн бұрын
16mm
Ap to golt dekhaya sir ji
Your tamping rod is wrong side
Bhai galat temping rod use kar rahe ho.
You used a wrong tamping rod
@CivilEngineerShubhamGupta
Ай бұрын
Yes
Sir but what's the main purpose for doing this test and sir what's the difference between sieve analysis test and impact value test
@CivilEngineerShubhamGupta
2 жыл бұрын
Sieve analysis for checking size of agg, an एग्रीगेट impact value for checking strength of aggregate
@alizainkazmi4372
Жыл бұрын
@@CivilEngineerShubhamGupta thank you sir
Temping hi galat hai 10mm chahiye
Temping ko sidha pakdo
Very nice 🙂
Tamping nai hota he bhai
@AbhikashyapKashyap-iv4qs
4 ай бұрын
Kaise bhai
Hhj
Tamping Galt h
Bhai glt mt batao jo tum taping glt hai
Is code no. Bataye
@shubhmmishra9956
Жыл бұрын
IS 2386 part 5
@dheerajmishara1551
Жыл бұрын
@@shubhmmishra9956 hiii
@shubhmmishra9956
Жыл бұрын
@@dheerajmishara1551 yes
@dheerajmishara1551
Жыл бұрын
sir Lab technician ka information dijiye please sir.......
@shubhmmishra9956
Жыл бұрын
Dear @@dheerajmishara1551 You should have 1:- Good Knowledge about testing (Construction Material:- concrete technology, Cement, Reinforcement, Aggregate-Fine & course Brick, Soil, Earth resistivity Etc.) 2:- good knowledge about lab testing equipment & formates. Regards Shubham Mishra Asst. Manager-civil(QA/QC)
16mm
Sir apka mobile number mil skta hai kya
Good 👍