AC में थोडी देर बाद कूलिंग क्यों बंध हो जाती है ? AC stops cooling after sometime?
Ғылым және технология
AC stop cooling after some time
App Link
play.google.com/store/apps/de...
Join this channel to get access to perks:
/ @actechpro
My accessories
Camera - amzn.to/30EgcNK
Mic - amzn.to/3nAZx7A
Tripod - amzn.to/2GByxUB
Laptop - amzn.to/3ddN30L
Bluetooth Speaker - amzn.to/3lnbImA
Headphones - amzn.to/30H0i5g
Drill Machine - amzn.to/3dxItKO
Multi meter - amzn.to/3fKH2dr
KZread Channel
/ actechpro
follow our facebook page
/ actechshekhawat
Пікірлер: 294
please make a video of How VRF unit working principle?
Too good video.
Air in system....if not purged properly or vaccumed properly while charging refrigerant can also result in frequent high pressure trip of ac ...as air wil not liquify like refrigerant and wil put excess load on compressor...this usually happens on big central ac systems ... 12 th point ..nice video ...covered all technical points
@ACTechpro
2 жыл бұрын
Good added point ravi
Thnks bhai
Very nice 👍🌹
Super duper sirji
मेरा 1.5टन का वोल्टास का स्पलिनट ए सी है जो हमेशा ही जून के महीने मे कम्प़ैशर बार बार बन्द होता है
@statusbyjaggi8893
Ай бұрын
Same problem bro same ac
@akashgoyal2636
Ай бұрын
Same problem
@sandeepsinghyam7223
Ай бұрын
Seme ac seam problem
Sir compressor ki registance kitni honi chaya 1ton ac and 1.5 ton split ac
## outdoor unit me fan capacitor change Kiya ho to same value kaa Karna prega for example Samsung ke outdoor unit me 2.5mfd Ka capacitor change krke 3 ya 3.5 mfd Ka dalnese kuchh ser baad compressor band hojati he
Good videos 😊
## compressor Ka pumping agar Kam hota he tab bhi thodi Der me band hojata he. For example aap khali system me compressor chalate ho agar usme Aapka pumping 300 se 400 tak aata he to ok he warna isse Kam ho or back pressure speed se down hota he tab bhi Aapka pumping low he
Thanks sir
@ACTechpro
2 жыл бұрын
Your welcome
Zyada heat wala area jaha sun light direct ho ya fir zyada garmi ke sizen me for example march, April, may tab bhi compressor thodi Der heat hokar trip ho jate he
@Jyotichaudhary-0777
Ай бұрын
Eska koi upaay nahi hai jisse hamara ac cooling kre
Bro caarier ac main indoor unit chalta h Or compressure m chalta h. Kuchh time 10 minute chalta h. Indoor unit autometic off ho jata h indoor unit display light blinking hota h continue 1 minute.fir 1 minute k baad light blinking off ho jata h fir indoor chalta h.or pcb new lagaya. Gas thik h. Jaisa timer set ki tarah hota h.
Good teacher
@ACTechpro
Жыл бұрын
Thank you! 😃
## outdoor unit ka upper side Ka top laga hua naa ho, wo open ho tab bhi compressor thodi Der baad bnd hota he ese case me compressor khrab hone ke chances zyada hota he
Llyod 2 ton contractor wiring E3 eroor code kya reasion ho sakta h
Mana ki compressor me ⛽⛽ r 32 ki jagha pe r22 koyi dala ho to
Asha test me koin koin se sawal puchhte hai plz ek full video banaye sir ji
Sir aaj he ac lagwaaya aur ac chalte chalte cool nho kr rha fir thoodi dher baad coolong kr rha outer bnd ho jaa rha fir start ho jaa rha log bol rhe. Voltage ki dikkat hai bt main circuit me staplizer laga hai 250 volt aa rha fir kyu aisa ho rha
Sir evopretion kise kahete hai
## remote me agar aap temperature celcius ki jagah par ferenheat rakhoge tab bhi compressor thodi Der me temperature aane se band hojata he
Bhai,unit start hone time compressor normal hoga,kuch time chalne ke bad, discharge pressure perfect hoga,Lekin suction reed problem se wo proper refrigerant suck karnehi payega,phir wo proper refrigerant discharge karega nehin, naturally cooling stop ho jayega,ampre below hote jayega . Reply jarur Dena bhai.
Mera mitsubishi heavy duty srk18yvs w6 split ac hai. Chalne ke 10-15 minute baad cooling band ho jati hai aur green led light 6 times blink kane lagti hai. Kya reason ho sakta hai.
Compressor me oil Kaisa dalenge
## Purane models me ek case paya tha ki jab swing flapper motor jam Hoti he tab blower motor ki speed bhi Kam kardeti he uski Bina se coil thandi hokr sensor se compressor trip karwati he. Swing flapper motor kaa socket Nikal dene se compressor ok chalta he, reason wohi tha ki swing motor purani hone se jyada load le rahi thi.
@ravikantgadge260
Жыл бұрын
Sat 1 ton ac suruvat me 5 minit thand kar rahi hae. Fir nahi. Aur A 5 se .A 2.5 ho raha hae.. Plz .solution bataen
## inverter AC ke outdoor unit me condenser Pura clean he magar PCB area me kachra yaa rust laga ho ya Kisi ne wiring box khula rakha ho jisse kabutar ya Kisi birds ya insects ne kachra jama Kiya ho tab bhi 2 se 5 minutes compreeser chal Kar band kardega
## outdoor unit ka fan jiska wiring kisine Ulta Kiya ho for example motor se fan garam hawa bahar fekne ki bajay andar fek raha ho tab bhi compressor thodi Der heat hokar trip karta he
Hitachi window AC works fine with fan Speed medium and low but trips at fan speed High. Any solution?
Sir samsung ka ac hai uska 60 se automatic 120 hota hai candensor bhi saf kiya to bhi pressure badh ta hai Kay problem ho sakta hai
My samsung ac temperature not goes done below 25 c room temperature what will be the issue refill the gas after vaccum 2 times problem not solved
## outdoor unit Ka fan ya motor dusri yaa jugaad Kar ke lagaya ho or uska heat fekne ki design yaa shape alag hojati he tab bhi compressor thodi Der heat hokar trip karta he.
E 1 se bhi aise problem hoti h kyaa
Nice
@ACTechpro
Жыл бұрын
Thankyou
## outdoor unit me agar motor ki shaft ghumti he magar outdoor kaa fan Nahi gumta he yaa outdoor ki motor or fan Ka shaft free yaa rouse hota he tab bhi compressor thodi Der heat hokar trip karta he
Ampere ki deflection hote hai garm hava dena shuru kar deta hai A. C. Plz tell me how to rectify it
Our Hitachi 1.5 ton window ac 3 star after 2 or 3 hours it becomes jaam, then we stop and restart after 20 minutes, it works again. But it jaams again after 3 or 4 hours. What is this.
Sir mera ac Hitachi ka hi duphar me garam hawa phekta hi new liya hi esa kyu 2 tun ka hi kya kami hi abhi 10 din bhi nh hue hi liyewe
Mere Blue star 1.25T window ac ka temp. 28 se neeche nahi horaha hai...gas poor hai kahin leakage nahi hai
## indoor unit Ka blower motor kharab ho ya jaam ho yaa shaft uski rouse ho chuki ho yaa blower se zyada motor gumti ho tabhi ye dikkat Hoti he coile thandi hokar sensor se compressor trip karwata he
Mera 1 ton ka AC hai Panasonic company ka AC chalu karne ke bad thodi bar cooling hota hai aur bad mein uska jo temperature ka indicator hai usmein se Lal light blinking hoti hai aur bad mein aisi automatic band hota hai iska kya problem hai aap bata sakte hain kya dhanyvad
Mera bindow a/c hai, ye ese chalta hai, lekin dopahar ko sound aata hai orculing band ho jati hai, night main chalta hai condensor bhi change kiya tha
Sir batatye kya Kiya jaye
Hitachi inverter split AC ka compressor din me bar bar (20-25 sec bad) tip kar raha hai, or kuch der bad outdoor and indoor dono bandh ho raha hai 4 time blink ke saath. lekin raat me bilkul sahi chal raha hai. Iss ka Karan kaya hai...
## indoor unit Ka blower Kisi ne alag design Ka Kiya ho tab bhi cooling thodi Der baad bnd ho jata he.
3minute split AC chalne ke bad start hona,Punha start challah kya Karan hai,bataye
Sir meri AC panasonic ki hai aur vo kuch der chalti hai aur kuch der cooling karti hai phir band ho jati asa baar baar par karti hai mai kiya karu
11tr ki r407 gass me h or suction pipe pr ice aa rha h
Sir 5mint chlna Ka bad compressor band ho jata h new capater bi dak Ka dik liya liki problem solve ni Hua?????
Sir ac kabhi cooling kar rahi hai kabhi nahi kar rahi hai is topic ke upar video bana do or sir ac ki caplary or ac ki pipe kahi par bhi moisture choking ya oil choking ho to kaese findout kare ki ac me choking ki problum hai is topic par bhi video bana do plz sir - My name is Mohammad Adil
Piping distance long hone se bhi normal 1 ton AC ke compressor kam Nahi Kar pate.
## outdoor unite me compressor 5-10 minutes chalne par suction line par return proper aata hoga magar after 5-10 minutes compreeser ke piston ya michenism me kharabi ki wajah se awaaj karke band hota he or sirf fan on rehta he or suction line garam hojati he
@deepakmittal7736
2 жыл бұрын
Same condition...plz reasion btao
@KahkashanAnsari2000
2 жыл бұрын
Same problem
## inverter AC me outdoor unit ke sensor Kisi Tarah se kharab ho ya kisine kutar diye ho tab bhi compressor humming leke bnd hota yaa start Nahi ho pata he error dekar.
Ac ko dobara chlane k baad hot mode me chla jata h 4-5 baar reset krne pr cooling dene lag jata jaise hi supply jati h hot air dene lag jata please reply split ac duel inverter h
Sir ak sharp eco inverter ac hain o 4ams leka 5min Chalke compressor band ho ja raha hain ??plzz tell me sir ..
@ACTechpro
2 жыл бұрын
Check error code on display and if not showing any error code on display check ODU PCB light blink error
Sar mera ek hi voltage 1.5 tan hai usmein ice a jata hai filter aur capillary change Kiya Hai Uske bavjud Fir se Ab Kya Karen
Sir hamara ac 2 ton ka h to Jab lae the tab to first day ko bahuthi Acha cooling ki this but uske second day se hi cooling kam hogai or jisse liyatha vo man hi nahi raha hai ki ac me koi khrabi h .
Voltas window AC h 14 ampeir pe chal Raha hai cooling kam h kya kare
Mere ghar me carrier sprit a.c hai wo din me chalte chalte band ho jata p6 likha ke ata hai lekin raat me bade aram se chalta hai esa kyo hota hai
Ager outdoor pura sistem sahi hai conteckter dabane par chlta hai chod dene par band ho jata hai kya problem ho sakta hai
Sir ji mera split Ac ka pankha pehle se kam chal raha hai,or cooling bhi jyada nahi deta please batayein
Bhai ac thik h outdoor khrab ho gya koe dusra outdoor lga skte h.. Plz bhai reply
Okay I got it. Technician ko bulana hoga
Please solve 🙏🏻 my problem
plz sir btye... ac chlte chlte mode lg jata hai .. automatically jiss se cooling nhi hoti fan fan chlta hai plz sir btye kya kre
Sir problem ko sol krne ke liye koi whatsapp group h kya?
Sir out for bar bar me bnd ho rha h eska kya solution h
Sensor problem sa outdoor on nahi hora agar blower motor kharab hogi thabi bhee outdoor work nahi karaga deepbtahoo transfarmar kharab hoga tbee outdoor on nahi hoga
Sir panasonic ka ac h Or vo evening ke 6 pm se le ker morning ke 9 am tak badiya chalta h But afternoon me vo chalta tho h but hot air detha h Ac wale ko dikhaya tho vo stabilizer change kerne ko bol reha h Aap ke points mughe ache lege Tho kya aap mughe iska reason betha sakthe ho
@lokeshzindgijeelo8308
2 ай бұрын
Same problem
Cassette AC hai uska main sab kuchh ok gas bhi ok hai condenser heating bhi achcha Nikal Raha Hai per cooling nahin kar raha hai to kya problem ho sakta hai please batao bhai
## inverter AC me mostly Panasonic me 10 minutes chalne ke baad " df" defrost me system deta he jisme pcb regarding issue rehta he agar dusri pcb replacement yaa repair karwani padti he
@toshikazone6394
2 жыл бұрын
K8
Sir Hitachi 1.5 ton inverter hai par temperature pura hone pe cat nahi hota
Hmara Daikin ka ac h ampr shi h or compressor tirp ho rha h 2 gante bd outdoor fan chal rha h lekin compressor on nhi ho rha h
Mera ac 1.5 ton hai uska out dore thodider cooling karta hai aur badme turant band hota hai our uska picheka fan aur Indore ka fan bhi slow chalta hai please madat kijiye
Bhaiya ji Hamare ISI mein बार-बार ch41 likha hua a raha hai aur calling cut rahi hai ham Kya Karen bataiye
## indoor unit me nut jaha se tight hota he Jo hissa spring se lipti pipe yaa fir kahi or Kisi piping se pinch ya pipe dab chuki ho to aap meter guage se pata krne par kanta up and down hota rahega stand by Nahi rahega tab bhi compressor thodi Der me band hojata he
@bachokaislam7283
2 жыл бұрын
Asslam alikumm sir Mera Kenwood AC h 10.mnt chlta h phir just hwa deny lgta coling khtm ho jati phir 10mnt bad coming start ho jati bht preshan main 1,5 daidh tun AC h Mera 23 hzar bil Aya h es bar plz help me
@bachokaislam7283
2 жыл бұрын
Jo Msla h bta dein
Mera Ac Raat me sahi chalta din me baat baat trip hota hai, outdoor pe dhup bhi nhi padti fir bhi,aisa to nhi ki voltage ki wajah se ho rha hai raat me voltage achhi aati ho din me nhi is wajah se trip hota ho,212-213 ampere voltage aata hai
must reply
Mera 1.5 ton ac h .. hardly 2 min chalta h uske baad garam hwa deta h .. uska kya reason ho skta h
16-6-23 ko technician ne aakar mera voltas 1.5 ton AC ko re install aur service kiya lekin ab cooling thik se nhi ho rahi hai, kya kru
Split ac k indoor unit me ice smoke ya grill se pani ata hai kiyon?Jabki suctii oressure discharge pressure ampere rating sab thik hai..?
@ACTechpro
2 жыл бұрын
Clean indoor coil & check blower speed
sir ek split ac h...panasonic company ka...usme ac chalta hai sahi cooling karta hai aur amp vo sahi le raha.5-6amp h ..Gas vgera sb ok hai magar 30mint chalne k bd...ac cooling dena band kar deta hai lekin compresure band nh hota...compressure or fan dono hi chal rahe hote hai....aur amp jo hai 2.5amp ho jaate hai..fr uske bd amp badhte nh hai or dono ac ke suction or discharge pipe garam ho jaate hai mtlb normally garam...hote h.....or fr 30mint baad ac ko off kr ke chalate hai to fr ac thk thaak chalne lagta hai aur amp bhi 5-6 aajate hai..to esme kia dikkat aa rh h...ki compresure k amp 2.5 amp ho jate h mgr cooling b bnd ho jaati h mgr compressure chalta rehta h btaye sir
@dushyant1159
Ай бұрын
Kya problem thi aapke AC m
Aadha ghnta Ac sahi chlta h fer outdoor band ho jata h coil sensor badal dia ac service bhi krw di capacitor bhi badal diye fer bhi same issue h kya kare sir
1.5 ton ac h 2 min outdoor fan chlega band ho jayega or fir ni chlega cooling bhi ni hoti h kya kiya jaye
ek help chaihiye thi mere yeha light bar bar chali jati hai kabhi aati hai kabhi chali jati hai aur air conditioner remote se on hota hai jaise ki raat ke 3 baj rahe hai light chli gyi fir mujhe remote se hi on karna padega kya yrr chahe mei soo raha hu khud Automatic on nahi ho sakti hai kya
Back to back outdoor unit installation
@ACTechpro
2 жыл бұрын
Very good khan bhai.
Windo Panasonic ac aoto chalu bandh kyu nahi hota hea
Mere ek bar e6 error aya tha Electrolux
Kha se ho bhai aap
सर जो ऐप आप बनाए हैं उसको इंग्लिश टू हिंदी ट्रांसलेट करें कृपया
Bhaiya mera new Ac h lyod ka Ac kam nahi kar rha h jese hi cooling start hoti h band ho jata ha apne Aap
Sir refrigerant pressure zyada hone se bhi thodi der baad Compressor trip kar jata hai
@entrepreneur172
2 жыл бұрын
Good
@ACTechpro
2 жыл бұрын
Point no 12 .Very good
The current is directly proportional to the voltage and inversely proportional to the resistance. This means that increasing the voltage will cause the current to increase. Ek baar ye b dekh lena bhai 2:28 par aapne bola ki voltage decrease hone par ampere increase hoga 2:28 .
Pcb mins display me
Ductbal ac ushaka compressor chall leaking cooling nahi hota hai
Pcv me compresser sign show karta hai lekin kabhi kabhi cooling nahi hoti, aisa kyu
Sir मेँ आपका app, ac, tech डावनलोड कर रख्खा हैं पर उसमे daikin कैसेट ac के बारे मेँ कोई एरर नहीं हैं 2टन का कैसेट ac है15मिनट चलने के बाद coling बंद हो जती हैं
1.5ton LA window at hi chalta hi cooling karta hi kuch der ke Bad ex horable sound keep sath Band ho jata hi air tine keep Bad fir so suru hota hi
Sir hvac ki videos milegi ky???
@ACTechpro
2 жыл бұрын
See videos on my channel
Sir ac thodi der chalne k baad usme df ata hai or ac chalta rehta hai or cooling nhi hoti