6.17 Analyse the Structure and Check the Behaviour │ Design of RCC Building by ETABS │ Akshay Thakur
Lecture: 6.17 Analyse the Structure and Check the Behaviour
Download Attachment to the Lecture:
[Excel Sheets for Analysis Checks as per IS 456 and IS 1893 Part-1] drive.google.com/uc?export=do...
[Excel File: Design of RCC Building as per Indian Standard by ETABS] drive.google.com/uc?export=do...
[IS 456: 2000] drive.google.com/uc?export=do...
[IS 1893 (Part-1): 2016] drive.google.com/uc?export=do...
[Free] Course: Complete Design of G+3 Storey RCC Building as per IS Codes by ETABS
Course Instructor: Akshay Thakur
Watch Complete Course for Free on KZread: • [Free Course] Complete...
Download Course Brochure: drive.google.com/uc?export=do...
Course Description: In this course, you will learn how to plan structure with respect to architectural planning and as per codal provisions of Indian Standard codes then you will learn how to use IS Codes to calculate the loads on the structure and modelling and analysis of building structure in computer software ETABS, and most importantly you will go through the design procedure of each type of structural element manually as well as with the help of MS Excel Sheets and at last how to detail your structural sections and preparation of drawings for Construction-Site Execution purpose.
Download All Attachment Files [Resources] of Course: drive.google.com/drive/folder...
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
I hope you'll have a great time with my course and will learn a lot.
I'd be happy if you would give me some feedback about the course in the comment box.
Good reviews help others to find this course and enough positive energy will push me to create another course in future!
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Healthy Discussions and Queries are always Welcome inside Comment Section
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
You can also follow me on:
Blog: explorecivilsights.blogspot.com
Telegram: t.me/akshaythakur_civilengineer
KZread: bit.ly/youtube-akshaythakur
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Keep in Touch with me on this KZread Channel for, New Videos/Courses in Civil-Structural Engineering
Happy Learning,
Akshay Thakur
Пікірлер: 119
sorry for making some part as blur for lateral sway check.... the only things is you need to consider wind load cases for lateral sway check and compare with H/500 value..... hope you will not face any difficulty for that....
@AkshayThakur
3 жыл бұрын
@Arif Jamal thanks dear.
@nikhilkurtarkar427
3 жыл бұрын
Bro i do not get beam deflections in animations but get the slab deflections. Any idea why?
@AkshayThakur
3 жыл бұрын
@@nikhilkurtarkar427 check all the assign properties and loads over the beam, if it is still not showing then once reinstall software...
Very good information i get from this video 🙏
@AkshayThakur
4 жыл бұрын
happy learning ...
@AkshayThakur awesome.
@AkshayThakur
6 ай бұрын
thanks....
Very good 👍..will follow you
@AkshayThakur
3 жыл бұрын
Happy Learning!
thanks akshay sir for helping me out in my final year project.
@AkshayThakur
3 жыл бұрын
Welcome Dear!
awesome
@AkshayThakur
4 жыл бұрын
thank you, pranabesh sen
Thanks Akshay for your help. Can you tell check for shear force and bending moment as well like the way you did for torsional Irregularity.
@AkshayThakur
3 жыл бұрын
After Analysis Go to Option "Display" under which you can check All the forces for each member for any load/load combination/load combination envelope...
Epic
@AkshayThakur
4 жыл бұрын
thank you ... ezhil arasan
Hello again! I've used your method for analyzing a structure of my own design with Shear wall(I've also meshed the shear wall). While check model, i didn't get any error. But while running the analysis, my structure seems to have no error, but it says warning for some equations not solveable and lost accuracy. what does it mean? please explain. It says OK. in all required places though.
@AkshayThakur
3 жыл бұрын
is that you provide proper restraints to support, that might be the reason...
@arulselvan6768
3 жыл бұрын
Thank you for your reply, i rectified my mistake. I designed a multistorey single core structure with the help of your method. Ratio of max and min displacement was more on the shear wall side having openings. I reduced the opening sizes, and the structure got corrected and warnings as well as the ratio got satisfied.
@arulselvan6768
3 жыл бұрын
I read your comments to others as well, so using that i realised where to correct and corrected my mistake. I understood very well based on your teaching. Thank you for such a great course!
@AkshayThakur
3 жыл бұрын
@@arulselvan6768 thanks for the feedback...
Sir, won’t we check for story drift, torsional irregularity and lateral sway in negative x and negative y direction? Please do reply.
@AkshayThakur
3 жыл бұрын
here structure is symmetric so no need to check in negative direction so that I don't made that.... hope you get it! for irregular structures we need that one...
sir what are the other checks other than this we have applied if we are designing multistorey apartment
@AkshayThakur
3 жыл бұрын
there are a lot different checks if the building is high-rise and for such buildings you need to check for various paramenters for minimnum base shear, scaling response spectrum, number of modes, mininum frequency, p-delta, etc. as per IS.1893.1.2016 and IS.16700.2017
please upload tutorial on dynamic analysis of structure
@AkshayThakur
4 жыл бұрын
pranabeh sen, your suggestion i will take for future video creation.
Sir while checking torsionally irregularity u used eq load case .why u didn't use service load combination as done in case of drift and sway ?
@AkshayThakur
4 жыл бұрын
Read IS 1893 Clauses, Carefully ... you will got the things when to take Load and when to take Combinations ...
@AkshayThakur
4 жыл бұрын
in IS 1893.1-2016 Table 5 says consider Lateral Load and check displacement and it should not be more than max to min ratio of 1.5 & for storey drift Cl.7.11.1.1 states all loads need to be consider with 1.0 partial safety factor, where as as per IS 456 load combos with partial safety factor 1.5 and 1.2 are design load combination and 1.0 are serviceability load combinations & for Lateral Sway, here we not consider gust effect, and so that i take serviceability load combinations ... & basically serviceability load combinations are for check for deflection and crack .... Watch Video carefully ...then, no concept will miss ... Happy Learning!
@prashantkhanal246
4 жыл бұрын
@@AkshayThakur thank u sir 😊
@AkshayThakur
4 жыл бұрын
welcome, prashant ....
Hi sir I have a doubt that is for calculation of lateral sway we are taking service load combinations, we have 33 service load combinations. when we apply this all load in X direction then 33 deflections results should shown same thing will happen in Y direction. ie 33+33=66 sway deflections result should show but in your excel sheet only 34 deflections result shown. Please explain this.......
@AkshayThakur
3 жыл бұрын
for lateral sway use load case wind load not load combinations...
@harshalmore4437
3 жыл бұрын
Ok thanks
I v modelled the same structure and applied SIDL using brick wall ...after i run the analysis storey drift fr some combination z exceeding the limiting value..plz help.. 🤔
@AkshayThakur
Жыл бұрын
check the model - all properties, joint intersection points, earthquake load pattern details.... it should not happen because this is very small structure with good enough framing....
_If you complete the course, then I'd be happy If you give me the feedback of this course by just filling this google form_ _forms.gle/Q7gUW4untqbBszfs8_
At 4:18, when i go for filter option for story drift, I didn't get the Design & service load combination list ...In your video its showing 1 of 700 files in story drift but in mine it's only 54....but when i go for "Story max over avg displacement" than all the options of design and service load is coming in filter same like yours in the story drift filter....I don't know why it's happening in my latest verison of etab 20 file...Any solution Sir ?
@AkshayThakur
2 жыл бұрын
i'm haven't operate on the latest version of ETABS so that i'm unable to explain but upto version 18 they has the option availble as i shown in the video....
@sanguine6071
2 жыл бұрын
@@AkshayThakur Ok sir no problem...and thanks for providing such a knowledgeable content...hoping to see some more videos like these on other courses as well in near future...
sir I enable copy the data from table in etabs 18.2 which verson is best
@AkshayThakur
3 жыл бұрын
over the version ETABS 2015 (V.15) all have almost same interface... I suggest use latest version!
sir,i have done story check ,for some combinations the story drifts are failing , what to do now
@AkshayThakur
3 ай бұрын
add column/ shear walls or thicken the existing sizes in particular direction in which it fails.... adujst stiffness at storey where it fails...
sir we havent assign the windload on structrue..displacement table is not coming for wind load
@AkshayThakur
3 жыл бұрын
only for load cases and and combination respective directionwise displacement are calculated by etabs under option display -> tables
@misbahkhanam949
3 жыл бұрын
@@AkshayThakur ok sir ..thanks a lot
Hi Akshay Thakur I run the analysis But it is not showing the deformations after running the analysis but I can see the last analysis log
@AkshayThakur
3 жыл бұрын
it you click run analysis and if process is completed then you can go to option display under ribbon and check deformation for any load case or load combination, it will be display... if they are not showing then there may be a software problem or any other problem!
how do we know which load combination is to be used for which analysis?
@AkshayThakur
3 жыл бұрын
load combinations are depends on type of structure, soil type, building orientation (orthogonal/non-orthogonal) refer clause 6.3 of IS.1893.1.2016
@AkshayThakur
3 жыл бұрын
depending your conditions of building structure you need to prepare load combination by following set of rule in clause 6.3
How to correct if I get torsional irregularity is greater that the stipulated code of 1.5?
@AkshayThakur
Жыл бұрын
see the new amendment in which code modify value if it is less than 1.2 then no torsional irregularity, 1.2 to 1.4 torsional irregularity exists, more than 1.4 extreme torsional irregularity.
@AkshayThakur
Жыл бұрын
if you want to correct torsional irregularity then either you have to work on your modal analysis results or otherwise make the displacements at all corners in control by adding shear walls so no coupling torsional action will generate for seismic loads.... hope it helps...
what shall be done in case torsional irregularity fails for EARTHQUAKE IN Y DIRECTION + Eccentricity
@deveshjaiswal2711
Жыл бұрын
4 VALUES COMING AROUND 2.2 TO 2.9
@AkshayThakur
Жыл бұрын
means your modal analysis results are not upto the mark....
@AkshayThakur
Жыл бұрын
see then it is in earthquake+-eccentricity case then for small structure you can ignore it.... but, it must satisfy for general load pattern ELX and ELY
@AkshayThakur
Жыл бұрын
for particular direction your torsional irregularity fails means.... you have to check deflected shape in plan for that particular direction and see one of your end is twisting more so.... to avoid this twisting you have to make your building stiff to part where displacements are higher by doing change in column orientation or adding shear wall or resizing column etc.....
SIR IF OUR STRUCTURE IS TORSIONALLY IRREGULAR THAN WHAT TO DO.WHAT CHANGES SHOULD BE MADE
@AkshayThakur
3 жыл бұрын
then you have to maintain structure weight balace by adding or removing or reaggranging structual elements like beams, columns and shear walls, w.r.t. diaphragm centre as per your results of x & y co-ordinatates which are given by ETABS
what is the solution if the building fails in torsion irregularity check?
@AkshayThakur
3 жыл бұрын
change the arrangement of structural plan to make structure stable!
@argenkarmacharya2724
3 жыл бұрын
What if we just carry out the dynamic analysis(response spectrum) without changing the geometry?...Is it ok?
@AkshayThakur
3 жыл бұрын
No, then also it will fail... See, Dyanmic Analysis just give you some more refine Base Shear more over your earthquake force distribution from Diaphragm to all structural members is same as it before so, it may there produce same kind of displacements so it won't change your torsional irregularity!
sir in the analysis log, number of joints shown in your log is 945, whereas in my log it is showing 940, your with restraints shows 47, mine is showing 42, your with mass is showing 96, mine is showing 71 and so on.... what could be the mistake that I have made??
@AkshayThakur
Жыл бұрын
that thing does't matter.... wherever your slabs are break, frame elements end ponts there joint created by etabs
@AkshayThakur
Жыл бұрын
Restraints means supports
@AkshayThakur
Жыл бұрын
might be, there are two extra joints in your structure so thats happen...
SIR WIND LOAD CASE IS NOT COMING IN THE DISPLACEMENT TABLE OF ETABS.PLEASE HELP
@AkshayThakur
3 жыл бұрын
check under load cases table (define -> load cases) is there wind load case is prepared or not... and also check, is it you properly assign the wind load pattern under option load pattern if it is still not showing then, it may be a internal software repair issue so I recommend you to reinstall the software...
@misbahkhanam949
3 жыл бұрын
Thankyou sir
Sir Can i get the Excel Sheets for Analysis Checks Please....,
@AkshayThakur
Жыл бұрын
check the description box...
n what about base shear check sir?
@AkshayThakur
4 жыл бұрын
Scaling is made for Dynamic Analysis for scaling Response Sprectrum Function with static earthquake load cases ... not for Static Analysis ...
Sir after analysis I cannot see the deformed shape.. how to make it visible
@AkshayThakur
4 жыл бұрын
Go to Display and Click the Option Deformed Shape w.r.t. Load Case/Combo you can get the results *model should be analysed and locked otherwise results will not shown...
@vss27
4 жыл бұрын
I think the analysis is not run properly .. what might be the cause... Usually after modelling and analysis in every FE software... Deform shape is visible automatically
@vss27
4 жыл бұрын
@@AkshayThakur in the display there is no option
@AkshayThakur
4 жыл бұрын
Always Check Model for any modelling error before analysis through the option Check Model under Analyze Option in ETABS otherwise software will check model throughly after you start Analysis... Don't run to many software in background if your system has less configuarations...
@AkshayThakur
4 жыл бұрын
if you unlock the model after analysis then this option is not click-able...
Sir nice tutorial but you didn't show the deflection check for beam,
@AkshayThakur
3 жыл бұрын
Deflction Check is applied and it is satify in Preliminary Design... Video 3.2 in the same course....
@binayaksamanta863
3 жыл бұрын
@@AkshayThakur ok sir Thank you, did you show how to do member offset in any of those video?
@AkshayThakur
3 жыл бұрын
no, only basic tools for drawing are used for modelling... check video 6.8 in the same course...
@binayaksamanta863
3 жыл бұрын
@@AkshayThakur ok sir Thanks
What if the story drift check fails. It is exceeding 0.004.
@AkshayThakur
2 жыл бұрын
it means your diaplacement values are high as in consideration with your storey hight... to overcome the failed results do anything according to you which can decrease the displacement such as make some changes in the floor plan layout or increase the vertical section sizes, etc.
@harishjoshi1139
2 жыл бұрын
@@AkshayThakur I used 500×500mm column size already. Than I increased to 550×500mm. It goes down to 0.005 still greater than 0.004. Could you help.
@AkshayThakur
2 жыл бұрын
change some structural arrangement.... btw sorry i'm nowadays busy in my schedule so that i am unable to check your structure!
@harishjoshi1139
2 жыл бұрын
@@AkshayThakur Ok I will check. By the way it's very simple box structure. No secondary beam nothing just a simple box structure of 5 story. I don't knw wht I have done wrong.
@AkshayThakur
2 жыл бұрын
sometimes secondary beams tie the floor system in an effective manner and so that those are helpful in many cases...
Hey bro.. i cant find the reosult table Display/show tables/analysis/ then the result is miissing Kindly help me where did i go wrong
@AkshayThakur
4 жыл бұрын
Results are shown only to the Locked Model [Analysed Model], Sometime because of time-out results may not shown so again view by refeshing the window ...
@AkshayThakur
4 жыл бұрын
Analyse Model by Run Analysis, then Check ....
plz upload the excel sheet of storey drift
@AkshayThakur
Жыл бұрын
all those sheets are there in description box... named analysis checks
@civilviews5336
Жыл бұрын
@@AkshayThakur sir error dikha rha hai
@civilviews5336
Жыл бұрын
That's a not a big deal sir we make own self, but thanku so much sir for this effort. No one can uploaded a full design video on any project but your are also provide excel sheet as well. Salute you sir
@AkshayThakur
Жыл бұрын
@@civilviews5336 where are you saying an error appearing?? please let me know!
@civilviews5336
Жыл бұрын
@@AkshayThakur sir showing 403 that an error