400 Feet borewell karwane se le kar submersible lagwane ka pura kharch || easy fit

Тәжірибелік нұсқаулар және стиль

Mail : - easyfit512@gmail.com
Contact :- 6201150992
Hello dosto aaj ki video me humne aapko borewell karwane se le kar submersible pump lagwane me kitna ka kharch aata hai uski jaankari di hain ummid karte hai aapko ye video pasand aaye gi
#Texmo2hp_submersible_pump
#Best_submersible_for_400feet_borewell
#Borewell_drilling_rate_per_feet
#submersible_pump_installation_video_hindi
#Ms_casing_pipe_rate
#easyfit

Пікірлер: 108

  • @Chikku771
    @Chikku771Ай бұрын

    Great❤❤

  • @bhartsahu6931
    @bhartsahu693118 күн бұрын

    Chhatisgarh bhilai Driling .. 80 rupay par fit Kesing .. 350 rupar par fit No. Extra dip charg Texmo motar 1.5hp 21 stej 14500 900000 me 400 fit complete ✅

  • @HariShankar-kr7ns
    @HariShankar-kr7ns16 күн бұрын

    JFS O15s + JRF A/16 ye h kya

  • @SiddhantPatil-ls8nj
    @SiddhantPatil-ls8njАй бұрын

    भाई मै महाराष्ट्र भिवंडी से हु हमारे इधर 94rs per feet Driling cost आता है.और Policab का 4mm 3core Wire 128rs per meter का रेट है.मै भि बोरिंग का काम करता हु.

  • @Easy_fit

    @Easy_fit

    Ай бұрын

    Great 👍

  • @abhishek5042
    @abhishek5042Ай бұрын

    Bhia drilling krate samye gover kur dalte ha

  • @sandeepkumar-ej9dg
    @sandeepkumar-ej9dg24 күн бұрын

    HDPE roll pipe kyon use nahi karte ho?? Column pipe se 50 % less price me mil jata hai..

  • @Easy_fit

    @Easy_fit

    23 күн бұрын

    Hamare ya use nahi karte log

  • @HemantKushwah-ms7yf
    @HemantKushwah-ms7yfАй бұрын

    Bhaiya 400 ft pr idol moter 3hp 35 stage single phase dalein hai lakin 50 feet paani main moter hai pressur se paani nhi de rhi kya kre.. Bataiye please

  • @Easy_fit

    @Easy_fit

    Ай бұрын

    Submersible ko 50 feet me rakhe hai to pressure kaha se dega or waise bhi aapka 3 hp 35 stage yeah jyda neeche se pani uthane ke liye hai na ke jyda pressure ke liye

  • @HemantKushwah-ms7yf

    @HemantKushwah-ms7yf

    Ай бұрын

    @@Easy_fit moter paani mai kitni feet ander rahni chaiye jese ki pressur de sake..

  • @HemantKushwah-ms7yf

    @HemantKushwah-ms7yf

    Ай бұрын

    @@Easy_fit Pressure ke liye kya karain kya moter change kre ya Or neeche 450 feet pr daal de abhi moter 400 feet pr dalain hain 450 feet dalne ke baad 100 feet paani main chali jaygi moter..... 2 ho texmo moter daalni chaiye ya nhi?? please reply

  • @niloyislam4777
    @niloyislam4777Ай бұрын

    Vai itna piam dena ka ke jororot he moje nahi samaj aia motor ki shat 7/8 pic paip dalnahi kafi ta vai ap 40 pic paip kis lia ditaho vai

  • @adityapandey5180
    @adityapandey5180Ай бұрын

    Bhaiya ksb pump try kariye..

  • @Easy_fit

    @Easy_fit

    Ай бұрын

    Jarur bhai hum bhi kosis me hai

  • @royalriya16
    @royalriya16Ай бұрын

    Mene aj hi li h lekin me लोरिंग ka wait kar Raha hun

  • @Easy_fit

    @Easy_fit

    Ай бұрын

    yahi pump ??

  • @user-rv5ch4is8h
    @user-rv5ch4is8h23 күн бұрын

    Jharkhand, ranchi se ho kya bhai

  • @Easy_fit

    @Easy_fit

    23 күн бұрын

    Yes bhai

  • @mjmunnamastivlog57

    @mjmunnamastivlog57

    12 күн бұрын

    ​@@Easy_fit apka dukan kha hai

  • @mjmunnamastivlog57

    @mjmunnamastivlog57

    12 күн бұрын

    Hmko 500 feet ke andar motor lgana h total bajat btaye

  • @Easy_fit

    @Easy_fit

    12 күн бұрын

    @@mjmunnamastivlog57 Instagram me msg kar dijiye bta denge

  • @bablokhatik7487
    @bablokhatik7487Ай бұрын

    Sar khet me bor kiya hai 7inch ka 350fit pe motor dalna hai awr2inch owt pot chahiye thibak ki paip lain me 3hp ka kambjit wala kaonsa motar dalna chahiye

  • @Easy_fit

    @Easy_fit

    Ай бұрын

    Sorry par jara clearly bataiye kuch samjhe or kuch nhi samjhe

  • @gjk7764
    @gjk7764Ай бұрын

    Balsiring Tupudana mein 190 feet ka boring hai r layer hai 4 inch toh sir kitne HP ka submersible lgana chahiye kindly jankari dijiyega

  • @Easy_fit

    @Easy_fit

    Ай бұрын

    1 hp 10 stage ghar ke liye hai tab

  • @PRAKASHKUMAR-cs1od
    @PRAKASHKUMAR-cs1odАй бұрын

    Mera borwell total 120 h kitna par motor dalna chahiye aur kon sa cri ka zuno 10 stege ya kiloskar ka 60 1008 jalraj 8 stege ka kon sa bhetar pani deja ye dono mera yaha 12500 ka set de raha h

  • @Easy_fit

    @Easy_fit

    Ай бұрын

    Bhai dono hi sahi hai koi sa bhi le lijiye

  • @santanudan6398
    @santanudan6398Ай бұрын

    Pump ke sath hi starter include rehta hai ya alagse lena parta hai 👈

  • @Easy_fit

    @Easy_fit

    Ай бұрын

    Starter included hai par starter ka price bhi included hota hai

  • @raaaj405
    @raaaj405Ай бұрын

    Bhaiya single phes me 3hp hai kya submersible moter

  • @Easy_fit

    @Easy_fit

    Ай бұрын

    Brand ??

  • @digambarmunda5848
    @digambarmunda5848Ай бұрын

    CRI pump 15 stage ka 230 feet me dala tha ek bar kuch der k liye Thoda pani nikla tha aur band ho gya sath me statar se pump me gya wire bhi garm ho raha tha iska kya karan ho sakta hai,

  • @Easy_fit

    @Easy_fit

    Ай бұрын

    Kitna hp ka submersible tha ? Kitna mm ka submersible wire use kiye hai ? Service wire kitna mm ka hai ??

  • @lalitsinghchouhan822
    @lalitsinghchouhan822Ай бұрын

    Texmo main 10 ya 11stage ki 2hp ki motor aati hai kya jiska outlet 2inch ka ho

  • @Easy_fit

    @Easy_fit

    Ай бұрын

    2 hp 10 stage agriculture submersible pump me aata hai

  • @sudhirkumarsingh9910
    @sudhirkumarsingh9910Ай бұрын

    भाई साहब मैं बिहार से हूं हमें सिंचाई के लिए 300 फिट बोर करवाना है और पानी 2,5 इंच मोटा आउटपुट चाहिए इसमें बोर कितना इंच मोटा करवाना चाहिए और मोटर कितना एचपी का लगेगा जानकारी दे

  • @Easy_fit

    @Easy_fit

    Ай бұрын

    6 inch se upper wala karwaiye tab v6 submersible lagega use bad agar pani mila borewell tab to pani hi pani

  • @sudhirkumarsingh9910

    @sudhirkumarsingh9910

    Ай бұрын

    इस पर भी एक वीडियो बनाए जिसमें संपूर्ण जानकारी मिले

  • @Arlofi-mix62
    @Arlofi-mix62Ай бұрын

    Bhai oil filled motor kya thik rahega

  • @Easy_fit

    @Easy_fit

    Ай бұрын

    Thik rehta hai low voltage ke liye jiske liye full video channel me upload hai aaap dekh ke sath sakte hai

  • @ramjanaksaket5899
    @ramjanaksaket589923 күн бұрын

    Bhai mai 2hp 20 stage ka pump lagava diya water pressure bahut kam hai 250 fit force ka pump hai kya karein

  • @Easy_fit

    @Easy_fit

    23 күн бұрын

    Kitna feet borewell hai ?? Ghar ke liye tha ya kheti ke liye ?? Kis brand ka submersible hai ??

  • @vinodrathor2151
    @vinodrathor2151Ай бұрын

    Mujhe boring krbani h 320 feet kasta ka casing pipe shi rahega kya or texmo ki motor ????

  • @Easy_fit

    @Easy_fit

    Ай бұрын

    Casing ki aapko alg se video mil jaye gi baki texmo ka pump best hai voltage sahi hona chahiye

  • @banjarafishers6615
    @banjarafishers6615Ай бұрын

    Bhai2 hp single phase me 400 ft ke liye motor kaun si achchi rahegi jo ghar Aur kheti mein kaam aa jaye borwell ki gahraai 800 ft hai

  • @Easy_fit

    @Easy_fit

    Ай бұрын

    Esi pump ko le lijiye 400 feet me kaam kare ga 1.5 inch ka outlet rahe ga

  • @jeetuchauhan5694
    @jeetuchauhan5694Ай бұрын

    Jinhone bhi esko dalvaya hai.. kitne beegha kheti sichayi karenge

  • @bharatpanchal7492
    @bharatpanchal7492Ай бұрын

    Bhai sahab ji mene borrwell krwaya h 500 feet ka pani thik thak h to muje single phase me kitne hp ka motor lagana chahiye or konse compony ka 450feet tk voltege180 se190 aata h

  • @Easy_fit

    @Easy_fit

    Ай бұрын

    Falcon 2 HP 25 stage le lijiye iski video bhi apko mil jaye gi channel me

  • @Easy_fit

    @Easy_fit

    Ай бұрын

    2 hp 30 stage submersible Agar stabiliser me kharcha kar lijiye ga to water cool lijiye Warna oil cool lijiye 450-470 feet pe install kijiye

  • @bharatpanchal7492

    @bharatpanchal7492

    Ай бұрын

    @@Easy_fit bhai sahab ji ye falcon wali moter kitne minimum voltege se pani nikal degi

  • @Easy_fit

    @Easy_fit

    Ай бұрын

    @@bharatpanchal7492 180-190 voltage me chalu ho jata ai falcon UTEE model sirf Hum install kiye the wala 170 voltage me bhi chal raha tha

  • @aryamansinghpundir
    @aryamansinghpundirАй бұрын

    Hello sir Agriculture borewell karana hai Humare yaha 350 feet pr paani hai usme kitne hp or konsi stage ki motor lagani chahiye.

  • @Easy_fit

    @Easy_fit

    Ай бұрын

    Video me jo pump hai vo 2 hp ka hai 1.50 mm outlate k sath ata hai chota kheti hai to isse achha koi pump nhi hai

  • @patelbhavanapatelbhavana1494
    @patelbhavanapatelbhavana1494Ай бұрын

    2 hector jamin ke liye kitna hp Pump chahiye 300 feet per

  • @Easy_fit

    @Easy_fit

    Ай бұрын

    V4 me ya V6 me lena hai

  • @tribaltrader750

    @tribaltrader750

    Ай бұрын

    V4 me

  • @Easy_fit

    @Easy_fit

    Ай бұрын

    @@tribaltrader750 jo video me aap comment kiye hai yahi submersible ko lga dijiye best hai

  • @shubhamsolanki4445
    @shubhamsolanki4445Ай бұрын

    Bhai kitne stage ki hai

  • @Easy_fit

    @Easy_fit

    Ай бұрын

    16 stage

  • @abhigyando
    @abhigyandoАй бұрын

    150 feet borewell me kitna hp aur kon sa summersible dale taki 3 ekad kheti me use ho sake

  • @Easy_fit

    @Easy_fit

    Ай бұрын

    Kitna inch wala borewell hai aur pani kaisa hai mila hai

  • @user-kk7qw6xw9c
    @user-kk7qw6xw9cАй бұрын

    kitna voltage chahiye eske liye ??

  • @Easy_fit

    @Easy_fit

    Ай бұрын

    210 se 230 minimum hona chahiye

  • @PanchamsinghUeriti
    @PanchamsinghUeriti29 күн бұрын

    Kitne phase ka he pump

  • @Easy_fit

    @Easy_fit

    29 күн бұрын

    Single phase hai !!

  • @DevendraSingh-or4nk
    @DevendraSingh-or4nkАй бұрын

    Bhai esme hdpe pipe use kyu nhi kiya

  • @Easy_fit

    @Easy_fit

    Ай бұрын

    Hamare area me HDPE pipe use nahi karte

  • @devishankarkatre2539
    @devishankarkatre2539Ай бұрын

    BhAi aap kuch alag types se costumer se jyada hi khrcha kr wate ho

  • @Easy_fit

    @Easy_fit

    Ай бұрын

    parso ek video aaye gi usme 1hp ke pump se kaam chal jata par costume ko 1.5hp hi chahiye jab ki uki jaurat hi nhi thi humare samjhne ke bad bhi unko 1.5 hi chahiye ab batao hum kya kare galt kaam karte hai to har roj motor sale nhi kar pate

  • @sonugari989
    @sonugari989Ай бұрын

    Kitna inch borewell hai

  • @Easy_fit

    @Easy_fit

    Ай бұрын

    8inch

  • @HumanBeing-ux1pi
    @HumanBeing-ux1piАй бұрын

    Apne kabhi 700 or 750 fit hang kiya hai ki nahi

  • @Easy_fit

    @Easy_fit

    Ай бұрын

    700

  • @HumanBeing-ux1pi

    @HumanBeing-ux1pi

    Ай бұрын

    @@Easy_fit koun sa pipe or motor best rahega

  • @Easy_fit

    @Easy_fit

    Ай бұрын

    @@HumanBeing-ux1pi ghar ke liye ya kheti ke liye??

  • @HumanBeing-ux1pi

    @HumanBeing-ux1pi

    Ай бұрын

    @@Easy_fit gher ke liye

  • @sunilkumar-yv7id
    @sunilkumar-yv7idАй бұрын

    ❤ ye pump 4 inch borbel me dal sakte hi

  • @Easy_fit

    @Easy_fit

    Ай бұрын

    Nhi

  • @sauravsanyal4397

    @sauravsanyal4397

    Ай бұрын

    4 inch me v3 lagega

  • @sunilkumar-yv7id

    @sunilkumar-yv7id

    Ай бұрын

    @@Easy_fit to koe acha taxmo ka agriculture ke liye bataa dijiye

  • @Easy_fit

    @Easy_fit

    Ай бұрын

    Aaram se v3 lagega Or agriculture ke liye kitna feet ka borewell hai or kitna phad wali motor chahiye

  • @sunilkumar-yv7id

    @sunilkumar-yv7id

    Ай бұрын

    @@Easy_fit 150 fir borbel hii 20 fit se Pani suru hii acha Pani bala pump cahyee

  • @playboynaksh3219
    @playboynaksh3219Ай бұрын

    4inchi borewell 210 foot krwana h ghr ke liye konsi motor lu 1.5 hp mein kitni stage ki v3, ya v4 or starter pannel , wire kitne mm lu light ki koi problem ni h plz rply fast

  • @Easy_fit

    @Easy_fit

    Ай бұрын

    v3 pump dalna pade ga 1.5hp 18stage

  • @playboynaksh3219

    @playboynaksh3219

    Ай бұрын

    @@Easy_fit v4 ni lga skte kya 4inch boring mein 15 stage 1.5hp

  • @Easy_fit

    @Easy_fit

    Ай бұрын

    Lag to jaye ga par risk bhi rhe ga pump fasne ka

  • @playboynaksh3219

    @playboynaksh3219

    Ай бұрын

    @@Easy_fit bhaiya 5inch lgwane ka koi benefit h ghr use me to btao aap kirloskar oil wali 1.5 hp 18 stage lu to shi Kam kregi kya jung to ni lgega usme

  • @Easy_fit

    @Easy_fit

    Ай бұрын

    @@playboynaksh3219 sahi hai lga sakte hai

  • @DevendraSingh-or4nk
    @DevendraSingh-or4nkАй бұрын

    Column pipe to mahanga padta hai

  • @Easy_fit

    @Easy_fit

    Ай бұрын

    Humlog column pipe hi use karte hai HDPE pipe yaha use nahi hota submersible me

  • @anilshinde8079
    @anilshinde8079Ай бұрын

    1.5 hp ka Kitana kimat hai

  • @Easy_fit

    @Easy_fit

    Ай бұрын

    1.5 hp 15 stage 16000 ka ata h

  • @sauravkumar-fw4qf
    @sauravkumar-fw4qfАй бұрын

    Kitna inch ke pipe dala hai 400 ft tak?

  • @Easy_fit

    @Easy_fit

    Ай бұрын

    1.5 ka outlet h 1.25 ka pipe

  • @sauravkumar-fw4qf

    @sauravkumar-fw4qf

    Ай бұрын

    @@Easy_fit Sir borewell pipe ka puch raha , jisme submersible pump dala hai ?

  • @Easy_fit

    @Easy_fit

    Ай бұрын

    Oo 8 inch ka hai

  • @AbhishekKumar-yi9ww
    @AbhishekKumar-yi9wwАй бұрын

    Texmo v6 3hp सिंगल फेज कास्टिंग पंप 4 स्टेज से ज्यादा का भी आता है क्या

  • @AbhishekKumar-yi9ww

    @AbhishekKumar-yi9ww

    Ай бұрын

    कितने कितने स्टेज का आता है

  • @Easy_fit

    @Easy_fit

    Ай бұрын

    Apko kitna stage ka chahiye

  • @AbhishekKumar-yi9ww

    @AbhishekKumar-yi9ww

    Ай бұрын

    150 से 200 फिट के बीच लटकाना है भैया जी तो 3hp v6 कितने स्टेज का लेना होगा सिंगल फेज

  • @AbhishekKumar-yi9ww

    @AbhishekKumar-yi9ww

    Ай бұрын

    केसिंग पाइप 7" है।

  • @Easy_fit

    @Easy_fit

    Ай бұрын

    5 se 6 stage plane body me

  • @sauravsanyal4397
    @sauravsanyal4397Ай бұрын

    Yar tum 4000 feet pe lgao

  • @Karan-xi7mm
    @Karan-xi7mmАй бұрын

    Bhai Check karne ke liye jab On Karoge Toh Pump me Current aata Hai Kya!! Body me jo Touch karne se current lage!!😅

  • @RANJEETBOSS150
    @RANJEETBOSS15026 күн бұрын

    Rasi ke jagah tochan wire kyo nahi use karte ho

Келесі