4 Concrete Test Live Practical | Slump Test | Cube test | Temperature Test | Rebound hammer Test
15 Mistake in House construction
• 15 Biggest Mistakes du...
15 Technical Term for civil Engineers
• 15 Technical Every civ...
Official Website Civil Site Visit
civilsitevisit.com
Daily New Job Links
civilsitevisit.com/recruitment/
WHATSAPP GROUP
chat.whatsapp.com/Kvn5i0GGzjp...
( TELEGRAM GROUP FOR CIVIL ENGINEERS )
t.me/joinchat/i84Oy3K0wqgzMjU1
t.me/joinchat/zwE9MYXIdgY5OWY1
( TELEGRAM GROUP FOR JOB UPDTAE )
t.me/joinchat/AzzpD2BS3qhmZjZl
( OUR OTHER KZread CHANNEL )
1. For Job Update
/ @civilsitevisitjobsupd...
2. For Business Idea
/ @businesskaadda12
3.Civil Engineer Sharma Ji ( Basic of civil Engineering )
/ @civilsitengineer
4.Pareeksha ( Job & Exam Preparation )
/ @civilengineerintervie...
10 Most watched Video of ( CIVIL SITE VISIT )
1. Tile or marble Flooring
• मार्बल लगाये या टाइल |...
2.How to decrease construction cost of House
• घर बनाते समय इन 5 बातो...
3.Construction Cost of 1000 Sqft House
• Construction cost of 1...
4.Parapet Wall Cheap & Best Design
• Parapet wall two Best ...
5.Wall Dampness Treatment
• Wall Dampness Treatmen...
6.Marble or Tile Flooring
• Marble or Tile ? which...
7.Cracks in wall repair
• घर की दीवारों में क्रे...
8.Mistake in House Construction
• घर बनाते समय इन 8 बातो...
9.1000 sqft House Material Quantity
• 1000 sqft का घर बनाने ...
10.ACC Block Vs Red Brick
• 1000 sqft का घर बनाने ...
CONTACT DETAILS
✔Email Id for Business Enquiry - rs140565@gmail.com
✔Twitter: VisitCivil?s=09
✔Facebook Page: / 100041543491213
✔ LinkedIn: / rahul-sharma-66324a215
✔Instagram: / civil_site_visit
✔Tumblr: / civilsitevisit
For Business Enquiry
7006672812 (Note :- Only WhatsApp )
Disclaimer - This video is for educational purpose only. Copyright
Disclaimer Under Section 107 of the Copyright Act 1976, allowance is
made for "fair use" for purposes such as criticism, comment, news
reporting, teaching, scholarship, and research. Fair use is a use
permitted by copyright statute that might otherwise be infringing.
Non-profit, educational or personal use tips the balance in favor of
fair use .
#ConcretetestLivepracticl #FreepracticalTrainin
Пікірлер: 404
Very nice
Tremendous job you are doing sir .... Keep it sir
Amazing video sir, most knowledgeable I can guarantee. Thank you so much. Keep providing us such valuable content. Thank you sir.
Very nice sir prectical video dekh kr bhut kuch sekhne ko mila Again Thank you so much🙏
Thank you brothet for giving practical information👍🏻🤝🏻🙂
Very nicely carried out practical concrete various tests and explained to understand even dull student. Best video
@pilotgaming8739
11 ай бұрын
F uk v
Very nice u r sharing greatful knowledge
Nice Explain & very informative video 👌
Explained very nicely. Slump test is done to test water cement ratio which has direct impact on the design strength of concrete. The reduction in height after the cone is removed depends on the type of concrete vis a vis design strength. For example concrete of M20, M25, M30 etc have different reductions in height after the cone is removed.
best valuable civil engg site technical knowledge
Great effort sir... 🙏🙏
Thanks For The Awesome Content Appreciate From Pakistan
Bhut hi badia video h Sir G.👍
Thnks for this type of video sir👍
Very informative video sir
MASS Scientific Sales Mr. Mahipat is very good work
Very helpfull question
amazing video...very interesting
Most useful video 👍
Thankyu so much sir ji👏👌👌Mene to apke ye test ke video pahle dekhe the aek aek krke lekin aaj fir se revision ho gaya sirjii superb plz sir or video banao jisse hame pura knowledge mil ske 🥰🥰👌👌👌🌷🌷🌷
@devrajsinghmarwadi4679
2 жыл бұрын
1 sariya Fitter+ 1 helper = _____ Kg. 1 Carpenter+ 1 Helper= ______ sqm. 8 ghante Ki Job me. Kitna Productivity Hota he practically.
Wonder full information
So important video ❤️❤️
Thnkuu for giving knowledge concrete testing
Sir bahot maaza aa raha h aap ka video dekh kr k
Very Nice..thanks
Hello Assalamualaikum good to see this video love it ...
Nice video very helpful
Jaldi se jaldi 1 million hoga
As per IS code 1199 2018.......We fill the slump cone in 3 layer of 25 time stroke each...The hole procedure should be done within the 3 min time frame
@princetomar6363
3 жыл бұрын
Right
@atoullshukkla5625
2 жыл бұрын
I also noticed same he said 4 layer 25-28 tamping Totally wrong. And again said 35 tamping in cube filling, he doesn't know any thing
@princetomar6363
2 жыл бұрын
@@atoullshukkla5625 25 time is right
@princetomar6363
2 жыл бұрын
I can proof
Very good job sir
Very helpful
Nice information sir
🙏 aapka bohot aabhar🙏🙏🙏
Excellent news
Best ever vedio
For slump test, number of layers is 3 and for each layer the tamping should be 25 times. Care should be taken that while tamping 2nd layer it must not penetrate 1st layer and same for 3rd layer, this test should be completed within 2 min, Ref: IS 1199(part-2):2018 (but your video is informative, keeping growing good luck)
@chandramohanpai2082
2 жыл бұрын
Test taken to make a video l don't think in india any bulider will waste time in such tests concrete comes pour it work done go home that is regular practise time pass video
@muqeemkhan8860
2 жыл бұрын
Now the standard has been change. You must penetrate the previous layer by 1 inch. The way he test the slump is bulshit. Slump must be fill in 3 layer. 1st layer 7 cm. 2nd layer 16 cm. 3rd layer 30 cm. Tamping in each layer must be 25 time.
@rashidhussain6182
Жыл бұрын
I agree with you
Very helpful Video for freshers sir thanks for making this.....these three test are very very important for civil engineer bring some more videos 👍
Thanks sir ji..
Best information
Great👏👏
Nyc work sir
Please upload this type of more videos
love you brother thank you
Informative
Very useful
Apka jo KN/Nmm2 ka volume ata hai usko grade of concrete se divided karo usse pata chalega ki kitna % hai
@sanjaykamble8537
Жыл бұрын
........
@karansahni6843
Жыл бұрын
adhoora gyan nhi please, KN/mm² ka volume? ye kya cheez hoti hai yrrr
@karansahni6843
Жыл бұрын
value likho typing error mtt kro boht freshers isi me confuse ho jayenge
Thankyou so much Sir
Thanks for this amazing content,
@civilpower610
2 жыл бұрын
kzread.info/dash/bejne/m6eLuNqHhcnWmbg.html
Thank you 💕
Practical dekh kar confidence bad gya sir
@khansirfunnyvideo3617
2 жыл бұрын
Aa a
Vah sir Love you from devbhumi dwarka ❤
@princetomar6363
3 жыл бұрын
kzread.info/dash/bejne/pX5rxNKYlqS9Z5c.html
@bijaynayak7325
3 жыл бұрын
Hyy
Very nice sirji
Thank you sir❤
Nice video sir
as per new amendment slump cone test also done in 3 layes
Nice sir jiiii ❤️
Nice video
👍👍 job 💪💪
Thanks u sir
so good
Very good
As per BSEN or ASTM for the slump testbitz only 3 layers...BSEN its says equal hight of layers,ASTM its says equal quantity for layers
thank u 🙏🙏🙏🙏
Thanks sir
Good 👍
Thank you
Keep it up
28 days ka calculation wrong hai 30*99/100
Wooooow...
Thanks🙏🌹❤
The slump test is considered failed as per bs when the concrete collapse. The concrete is too watery. Desired values are between 40 and 80 unless it's a pump mix with extra cement. The method for raising the cone is inappropriate, he should lift the cone from a higher or standing position. Anyway good initiative to show test on site. Kudos
22:25 Actually 7 days me 67% strength and 14 days days मे 87% strength achieved होनी चाहिए according with IS code 🙏
@udaisingh2549
Жыл бұрын
Which IS code
@udaisingh2549
Жыл бұрын
Apne konse IS code me dekha
Sir plz ek video brick test ka bhi or tiles ka bhi .waiting for positive response
Engineering👨🔧 key bahut video🎥 hain 😇😇😇 Apni bhasha ki baat hee kuch aur hain😇😇😇😇😇
Thx
Sir concrete mix design se video banaye plz
Thanku sir
Good 👍👍👍👍
Good
Sir water level kaise krte hai.. Floor ko up ya down Krna ho.. And floor slope kaise dete hai.. Theory video banao sir... Plz Plz plz sir
Nice
good
Make video on pqc
Ok plz may you share design mix of m30
ASTM standard as per 3 layer not 4 layer flings slump cone also lifting slump cone within 5-+2 second asper ASTM
@logiclessmind1525
2 жыл бұрын
Cube should be filled in 3 layers and slump cone should be filled in 4 layers
@shaikhfayaz8696
Жыл бұрын
@@logiclessmind1525 please let me know standard?
1 sample = 3 cube IS 456..... 30×28/100 wahh bhai Quality Engineer
rain water harvesting par banaiye please
My friend i'm not engineer but I know about concrete because i'm also did this work in kuwait international airport so I want a job
Pillars are already constructed upto base level.but sudden shortage of money had kept the construction work on suspension for five months. Do u think it will damage the bar that are open from the pillars
@chandrashekhar3929
2 жыл бұрын
Cement wash the exposed rebars including stirrups to prevent formation of rust. Rust is very dangerous as there won't be proper bondage with the concrete if the rebars have become rusty.
@rameshangala3565
2 жыл бұрын
Chemical coat for rods will be added advantage
Sir ultrasonic ka bhi video
Bhai QA QC or IBC standards pa b video bnao plz
ok Bhai
jittaa 4 saal me nhi pdhaaa uttnnaa 40 min me btaadiyaa sir aapne or site construction vaale ques. laauyee sir ap 🤗🤗🤗🤗
@civilsitevisit
2 жыл бұрын
🖤
bahut achha sir. Aap hmare office Aimil Ltd ki digital machine use kijiye achha result milega .
Wahh sir hamne bhi kiya college me
Which type of rod should be used for tamping in case of slump test?
@GODZGAMINGYT929
2 жыл бұрын
Tamping rod...
At 21:32 jo 22.5 hai wo metre me hona chahiye kyuki 150mm*150mm=22500mm ata hai aur isko metre me convert karne pe ye 22.5metre ho jata hai.....aur 600kilo N hai ya only Newtown? Bhai mujhe kuch jagah calculation explaining me error laga hai...
I am a civil engineering student from Government polytechnic mujhana hata kushinagar
Sir after how many days should we check rebound hammer test after pillar casting ?
Nw concrete filling layers has changed...ne it's 3..nd cube tolrance should b 150+-0.2