3g vertical rootpass big gap , capping waydown stringer

all about welding fabrication

Пікірлер: 20

  • @job38four10
    @job38four102 ай бұрын

    Before I retired from shipyard most welders used pulse arc, I used duel shield flux core with 75/25 gas, I get less spatter. Those Speed-glass air fed welding hoods are the best, I used them over ten years, my shipyard started suppling them in 2004.............

  • @welderausphil

    @welderausphil

    Ай бұрын

    Thanks your comment much appreciated

  • @farmerx165
    @farmerx1657 ай бұрын

    the carnage starts at around 11:41

  • @isaganicruz7588
    @isaganicruz7588 Жыл бұрын

    Great Content. Very informative and practical

  • @welderausphil

    @welderausphil

    Жыл бұрын

    Thanks your comment much appreciated .

  • @lifewithabe312
    @lifewithabe3124 ай бұрын

    Diameter wire did you use for root? Did you cap it with stick 7018 maybe?

  • @welderausphil

    @welderausphil

    4 ай бұрын

    Thanks your comment much appreciated 1.2 wire , all innersheild or gasless root pass hot pass and capping.

  • @steeljas4540
    @steeljas45409 ай бұрын

    😮😮😮

  • @welderausphil

    @welderausphil

    9 ай бұрын

    Thanks your emoji much appreciated

  • @arcjunkie
    @arcjunkie8 ай бұрын

    Is that inner shield? NR 233?

  • @welderausphil

    @welderausphil

    8 ай бұрын

    yes= innershield , no # fabshield 21B thanks your comment much appreciated

  • @steeljas4540
    @steeljas45409 ай бұрын

    Napapalaban po ang golden hands mo bro

  • @welderausphil

    @welderausphil

    9 ай бұрын

    Thanks your comment much appreciated

  • @user-dm8my8jw8m
    @user-dm8my8jw8m2 ай бұрын

    fitter setting , welding loong welding oke 😅😊 , F 16 Pilot Cleaning like Pepsi

  • @user-db8pl8cb1l
    @user-db8pl8cb1l2 ай бұрын

    that looks like complete dog shit how that passed vis inspection ill never know espically if he had to sign off or put wrkr id stamp on welds ill never know

  • @selerisosis6290
    @selerisosis62903 ай бұрын

    It's too bad. I welding like mirror!

  • @skitown11
    @skitown119 ай бұрын

    Why are you stopping in the beginning?This ain't stick welding. Run that thing. Something must be wrong. The cap looks like 7018 run over FCAW that wouldn't have passed visual inspection.

  • @welderausphil

    @welderausphil

    9 ай бұрын

    Thanks your comment much appreciated

  • @lifewithabe312

    @lifewithabe312

    4 ай бұрын

    Why would the cap not pass?

  • @ThadMcCormick

    @ThadMcCormick

    2 ай бұрын

    That’s garbage full of porosity why that shity 212 wire so slow should be using 233