(14) Check The P-Delta effect- Tall Buildings Design - Etabs
In structural engineering, the P-Δ or P-delta effect refers to the abrupt changes in ground shear, overturning moment, and/or the axial force distribution at the base of a sufficiently tall structure or structural component when it is subject to a critical lateral displacement.
in this tutorial you will see how to check the P-Delta effect of our model.
Excell File Link: drive.google.com/file/d/1j2Zk...
All Parts: • ETABS: 20 Story Buildi...
Part 01: • (01) Designing a 20 st...
Part 02: • (02) Strat new project...
Part 03: • (03) Define Section Pr...
Part 04: • (04) prepare the DXF f...
Part 05: • (05) Import the DXF fi...
Part 06: • (06) Define the load p...
Part 07: • (07) Define The Mass ...
Part 08: • (08) Define The Load ...
Part 09: • (09) Assign Loads- Ta...
Part 10: • (10). Automatically M...
Part 11: • (11) Assign Pier Labe...
Part 12: • (12) Assign The Frame...
Part 13: • (13). Assign Diaphrag...
Part 14: • (14) Check The P-Del...
Part 15: • (15). Check The Eccen...
Part 16: • (16) Check The Soft S...
Part 17: • (17) Check The Heavy ...
Part 18: • (18) Check The Torsio...
Part 19: • (19) Check The Story ...
Part 20: • (20). Modal Analysis ...
Part 21: • (21). Response Spectr...
Part 22: • (22). Check Spectrum I...
Part 23: • (23). Design Core Wall...
Part 24: • (24). Design Shear Wa...
Part 25: • (25). Design Columns ...
Пікірлер: 28
thank you so much for making these videos
how can i calculate incremental factor by rational analysis if there is p-delta effect?
Sir provided excle sheet in the description in not correct it's showing error. please provide the Excel sheet as shown in the video
Sir .. In which situation we need to add pdelta effect?
If P-Delta is needed in the case, what we will do next step then?
excel sheet link is not working? could you please shear it again?
HI ENGR. What to do after giving p delta combination.. again to check ? plz reply
Could you please upload ASCE-7-05 ?
In my case if it shows 'redesign' and i mean not showing 'no p delta' then what is the step to make it safe/no p delta.?? Please reply anybody have practiced this project.??
Could a reupload of the excel please be done
😍
DONT WE APPLY COEFFICIENT TO EARTHQUAKE IN P-DELTA?
Dear sir, how to prepare excel sheet? If not a problem, Can you send this excel sheet?... please 🙏
@ehsantutorials5020
4 жыл бұрын
Hi dear The excel file link is already shared in description of this video.
DEAR SIR,,, I WANT TO KNOW ABOUT THE ONE THING THAT IN THE LAST VIDEO/TUTORIAL YOU RAN THE ANALYSIS, AFTER RUNNING ANALYSIS WHAT IS THE NEXT STEP IS IT CHECKING THE P-DELTA EFFECT OR CHECKING THE STRUCTURE ELEMENTS TO KNOW ABOUT ITS BEHAVIOUR WHETHER IT IS FAILED OR PASS. PLEASE EXPLAIN IT TO ME IF YOU DON'T MIND THEN
@ehsantutorials5020
4 жыл бұрын
the next step is check the p delta effect.
@saeednegar709
4 жыл бұрын
@@ehsantutorials5020 ok thanks
@qureshisiddig9274
2 жыл бұрын
@@ehsantutorials5020 How we check the p deltta affect if i assigned wind load only on my tall building
Why you take P as a combination.... Please tell me what is in P combination formula
@muhammadnaveedkhan9587
4 жыл бұрын
@jever doran thanks I just simply define p delta all the time.. Hope it will not be wrong.
@md.sayefpasha6840
Жыл бұрын
all (dead load + live load) DL+LL
@md.sayefpasha6840
Жыл бұрын
Vertical Loads by gravity = P
Sir base shear check dibo kivabe?
IF THE MEMBERS ARE FALED THEN WHY YOU''RE GOING AHEAD...FIRST CHECKING OF MEMBER IS ESSENTIAL THAN GOING AHEAD
@ehsantutorials5020
4 жыл бұрын
I am going step by step . no members failed and not any mistake yet.
@saeednegar709
4 жыл бұрын
@@ehsantutorials5020 thanks for your efforts
interesante video, bien presentado. Tema importante. Saludos, dejo enlace de un video propio que espero les guste. kzread.info/dash/bejne/fXqtyayboriaips.html
Sir provided excle sheet in the description in not correct it's showing error. please provide the Excel sheet as shown in the video