Service call 1 beep code on Hoshizaki ice Machine. Leaves me holding my crank. #gopro #refrigeration #repair #hoshizaki
Жүктеу.....
Пікірлер: 43
@manhpham8052 Жыл бұрын
I had this 1 beeper keep bugging me for 3 months. Everytime i reset it and check to see if hot water filling, check the harvest timer completion, check thermistor ohm, check hot gas valve are all good. And everytime i reset it it would work like normal. However, i keep get call back on 1 beeper again. To the point i show the chef how to hit the alarm reset and it will work fine until i trip again. Call hoshizaki tech support, they tell me to tape a candle on the water line to see if it melt that mean hot water have enter unit some time that is difficult to cacth. I did that and the candle actually melted. It come to find down the water heater tank was set too hot and at night time when nobody using hot water, it flow back into cold water line. So that it something you wanna check Mr Dave if it keep doing 1 beep
@NorCal-refrigeration
Жыл бұрын
Great info!!!!!!
@manhpham8052
Жыл бұрын
@@NorCal-refrigeration hope u catch the problem. happy new year to you. i have learn alot from your video. im 4 year in the trade. hoping you still doing more video in the future for me and all the new tech to keep learning
@emanuelvelasco9042 Жыл бұрын
A good thing I like to do for 1 beep codes is to check the water level of the reservoir before I reset the machine. If the water level is low then most likely it was a water interuption like the city water was off for a bit, machine tried to make ice then brought no water in and evap got too hot. Keep up the good work love watching your videos.
@TheLenaweeTrekker Жыл бұрын
In just about all my #1 shutdowns, there was a water issue, but managers won't tell you that when you walk in. You usually get that intel from one of the crew. So you have to check the water trough and see where the water level is before you reset the machine.
@Onedown5ups2 ай бұрын
Had this same exact call a few days ago but with 2 self contained machines side by side both on a 1 beeper. Knew that the only thing they had in common was the water supply so it made it less of a head scratching call. Asked the manager if they had the water shut off at any point recently and sure enough the plumbers had been out there working the day before. Thank you Mr. Plumber 🫡
@harrydickson4575 Жыл бұрын
Holding your Krank lmao 🤣 😂😂 👍👍👍
@dose9056 Жыл бұрын
"Stuck there holding your crank" lol love it.
@IFIXCASTLES Жыл бұрын
Good job !
@throttlebottle5906 Жыл бұрын
Dave's full of hot gas! 🤣 at "I can feel my hot gas valve sticking"
@fredflintstone8048
Жыл бұрын
A little bit of abdominal pressure should open the valve and release the excess gas.
@eeeeweeezeee Жыл бұрын
Holding your crank indeed. It always works when the technician is staring at it!
@The98deville Жыл бұрын
Absolutely do not miss crawlspaces at all
@sherwinalvarez7365 Жыл бұрын
I hate when calls like this come in. Especially if after you leave they call back.
@user-kq9pl4jx9d Жыл бұрын
Our ice machine only beeps once when you turn it to "ice" mode and no more. The light on the board holds orange, except when you turn it on, for a few seconds there it switches to green. But yeah, no constant beeps like I see online.
@kingofthecrease30 Жыл бұрын
hot gas valves sticking open could be intermittent. Manitowoc is famous for that...makes 3 batches of ice fine then 4th batch it sticks open...reset it and it stick open at 2nd or 5th batch. Hoshizaki usually does not have hot gas valves sticking open...they are famous for leaking oil & refrigerant
@manhpham8052
Жыл бұрын
I ran in to the same issue with manitowoc remote where i replace the hot gas valve 2 times. The 1st time it like u said it made 3 batches with no problem, then it stuck close instead, did not drop ice. The second hot gas valve I replace under warranty, finally it work
@mikestevenson1819 Жыл бұрын
Nice dump !
@jamestoy426 Жыл бұрын
Holding your crank lol 😂
@MinniMoR Жыл бұрын
Here I thought o’l dave got himself a sponsor but he was just promoting healthy eating 😂
@throttlebottle5906 Жыл бұрын
maybe they had a water outage or low/no water over-night and it tripped out?
@gene-khvacr Жыл бұрын
These ice machine calls seems like average 3 hrs at least waiting for at k Least 3 cycles what not what do u think !
@jamnben278 Жыл бұрын
"Stuck there holding your crank"
@shine-cg9uf Жыл бұрын
👍💪🇺🇸❄️
@lee-johnson Жыл бұрын
That’s a conditioned crawlspace!
@dustinweber6803 Жыл бұрын
Any advice on a true gdm 49f ld, just grabbed it out of a scrap pile, needs a new compressor, OEM is over a 1000, any alternatives you know of?
@manhpham8052
Жыл бұрын
You can take a picture of the compressor nameplate and go to local supply house for them to match up the hp and pipe size. I used to do find my at Johnstone supply or United refrigeration
@marcoferreira226 Жыл бұрын
When I was a cable guy, I had to install a line in a crawl similar to the one you where in, I had to move some insulation and surprised 😯 face full is mice I never saw that coming. If I was running the 100m dash I would have won gold that day I have never moved that fast in my life. But I was 25 being 46 now I probably would just have some choice words and move on to what I needed to do. Raccoons just stay away from these creatures they are the devil. I have story but that's for another day.
@mikestevenson1819 Жыл бұрын
Do a video on the dip switches. In different positions
@fredflintstone8048
Жыл бұрын
RTFM
@sadafarida1260 Жыл бұрын
Everytime ive gotten this call the problem was water issues.
@jameshoney2506Ай бұрын
What is a typical time between harvests?
@NorCal-refrigeration
Ай бұрын
Up to 32 minutes
@philltafolla Жыл бұрын
I bet someone shut off the water , I betcha !!!!! What’s this BS something I say all the time 😊😀
@steveblake8766 Жыл бұрын
146 thumbs up
@thesilentonevictor Жыл бұрын
A back workout for you nor cal Dave
@ntsecrets Жыл бұрын
She's a chirpa!
@NorCal-refrigeration
Жыл бұрын
😂😂😂😂😂😂😂😂😂😂😂😂😂😂😂😂😂😂😂😂
@tompage4209 Жыл бұрын
why am I here
@jimsergi Жыл бұрын
I hate the middle of donuts
@jkim024 Жыл бұрын
The new design location of the control board sucks!
Пікірлер: 43
I had this 1 beeper keep bugging me for 3 months. Everytime i reset it and check to see if hot water filling, check the harvest timer completion, check thermistor ohm, check hot gas valve are all good. And everytime i reset it it would work like normal. However, i keep get call back on 1 beeper again. To the point i show the chef how to hit the alarm reset and it will work fine until i trip again. Call hoshizaki tech support, they tell me to tape a candle on the water line to see if it melt that mean hot water have enter unit some time that is difficult to cacth. I did that and the candle actually melted. It come to find down the water heater tank was set too hot and at night time when nobody using hot water, it flow back into cold water line. So that it something you wanna check Mr Dave if it keep doing 1 beep
@NorCal-refrigeration
Жыл бұрын
Great info!!!!!!
@manhpham8052
Жыл бұрын
@@NorCal-refrigeration hope u catch the problem. happy new year to you. i have learn alot from your video. im 4 year in the trade. hoping you still doing more video in the future for me and all the new tech to keep learning
A good thing I like to do for 1 beep codes is to check the water level of the reservoir before I reset the machine. If the water level is low then most likely it was a water interuption like the city water was off for a bit, machine tried to make ice then brought no water in and evap got too hot. Keep up the good work love watching your videos.
In just about all my #1 shutdowns, there was a water issue, but managers won't tell you that when you walk in. You usually get that intel from one of the crew. So you have to check the water trough and see where the water level is before you reset the machine.
Had this same exact call a few days ago but with 2 self contained machines side by side both on a 1 beeper. Knew that the only thing they had in common was the water supply so it made it less of a head scratching call. Asked the manager if they had the water shut off at any point recently and sure enough the plumbers had been out there working the day before. Thank you Mr. Plumber 🫡
Holding your Krank lmao 🤣 😂😂 👍👍👍
"Stuck there holding your crank" lol love it.
Good job !
Dave's full of hot gas! 🤣 at "I can feel my hot gas valve sticking"
@fredflintstone8048
Жыл бұрын
A little bit of abdominal pressure should open the valve and release the excess gas.
Holding your crank indeed. It always works when the technician is staring at it!
Absolutely do not miss crawlspaces at all
I hate when calls like this come in. Especially if after you leave they call back.
Our ice machine only beeps once when you turn it to "ice" mode and no more. The light on the board holds orange, except when you turn it on, for a few seconds there it switches to green. But yeah, no constant beeps like I see online.
hot gas valves sticking open could be intermittent. Manitowoc is famous for that...makes 3 batches of ice fine then 4th batch it sticks open...reset it and it stick open at 2nd or 5th batch. Hoshizaki usually does not have hot gas valves sticking open...they are famous for leaking oil & refrigerant
@manhpham8052
Жыл бұрын
I ran in to the same issue with manitowoc remote where i replace the hot gas valve 2 times. The 1st time it like u said it made 3 batches with no problem, then it stuck close instead, did not drop ice. The second hot gas valve I replace under warranty, finally it work
Nice dump !
Holding your crank lol 😂
Here I thought o’l dave got himself a sponsor but he was just promoting healthy eating 😂
maybe they had a water outage or low/no water over-night and it tripped out?
These ice machine calls seems like average 3 hrs at least waiting for at k Least 3 cycles what not what do u think !
"Stuck there holding your crank"
👍💪🇺🇸❄️
That’s a conditioned crawlspace!
Any advice on a true gdm 49f ld, just grabbed it out of a scrap pile, needs a new compressor, OEM is over a 1000, any alternatives you know of?
@manhpham8052
Жыл бұрын
You can take a picture of the compressor nameplate and go to local supply house for them to match up the hp and pipe size. I used to do find my at Johnstone supply or United refrigeration
When I was a cable guy, I had to install a line in a crawl similar to the one you where in, I had to move some insulation and surprised 😯 face full is mice I never saw that coming. If I was running the 100m dash I would have won gold that day I have never moved that fast in my life. But I was 25 being 46 now I probably would just have some choice words and move on to what I needed to do. Raccoons just stay away from these creatures they are the devil. I have story but that's for another day.
Do a video on the dip switches. In different positions
@fredflintstone8048
Жыл бұрын
RTFM
Everytime ive gotten this call the problem was water issues.
What is a typical time between harvests?
@NorCal-refrigeration
Ай бұрын
Up to 32 minutes
I bet someone shut off the water , I betcha !!!!! What’s this BS something I say all the time 😊😀
146 thumbs up
A back workout for you nor cal Dave
She's a chirpa!
@NorCal-refrigeration
Жыл бұрын
😂😂😂😂😂😂😂😂😂😂😂😂😂😂😂😂😂😂😂😂
why am I here
I hate the middle of donuts
The new design location of the control board sucks!
@NorCal-refrigeration
Жыл бұрын
Indeed